                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        CONTENTS    1. Web Connection.......................................................................... 2  2. Basic Setting............................................................................... 4   Information................................................................................ 4   Network .................................................................................... 5   Serial Port.................................................................................. 6  
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        10. Authentication .......................................................................... 22   Account ....................................................................................22   Accessible IP .............................................................................23   Default Setting ..........................................................................24   Reboot Setting ..........................................................................24        April 29, 
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual       Managed Switch   Web Management Operation      This manual will guide you how to configure  ICPDAS Managed Switch through web browser.   Connection   Basic Setting Web Management support two levels of   Redundant Setting  authentication : administrator level and user level.   Port configuration  The administrator level allows you to monitor,   Relay Alarm  configure and control all functions of Web   Email Alarm   VL
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual       1. Web Connection  The default network setting (factory default setting) of Managed Switch is :  IP   : 192.168.255.1  Mask   : 255.255.0.0  Gateway  : 192.168.0.1    Before accessing Managed Switch through web browser, please modify above setting to fit your  network environment, you can refer「RS-232 Console Operation」manual for more detail.    Following, we will show you how to connect to the Web Management step by step. 
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual            For login to Web Management, your browser must support  HTTP authentication. It allows a web browser to provide  credentials when making a request.        April 29, 2008  3                                                                                                                                                                                                                                                          
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual       2. Basic Setting  This chapter describes how to setting the commonly information on your Managed Switch.     Information     Module Name: : : :  Use to specify the Switch Name, and also displayed as the console prompt. Max. 8  characters.  Module Information: : : :  Use to memo the extra description of the Switch Module. 16 characters max..  Web Server TCP Port: : : :  Specify the connection port of the Web Server. Defa
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual          Only MS Series Switch supports a real time clock. For RS Series Switch,  the  function is invalid.           Network     IP Address: : : :  IP address is an identifier for a device on a TCP/IP network. It is a 32-bit numeric address  consisted as four numbers separated by three dots. The range of each number is from 0 to  255.  Managed Switch doesn’t support dynamic IP assignment, you have to speci
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual       Mask: : : :  The (subnet) MASK is used to determine the subnet of an IP address. Same as the IP  address, a MASK contains four bytes (32 bits) and it is often expressed in the dotted-decimal  notation.  The factory default value is labeled beside the Switch case.  MAC Address: : : :  MAC Address is a hardware address. It’s a uniquely identifies the device of MAC layer  network.  The standard (IEEE 802) format for human-read
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual       COM1 port is the RS232 standard, use for Console Connection. Factory default setting is:  Baud Rate  : 115200  Data Bit  : 8  Parity Check : 0 (None)  Stop Bit  : 1    COM2 is the RS485 standard, use for Modbus communication. Factory default setting is:  Baud Rate  : 115200  Data Bit  : 8  Parity Check : 0 (None)  Stop Bit  : 1       Digital Input / Output   ICPDAS Managed Switch supports 3 points of digital input / out
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual       3. Redundant Setting  Redundant LAN topology is a structure to provide the link failure recovery and escaping network  loops. It allows you to setup the redundant loops for supporting backup connections.    Managed Switch offers redundancy options for various functions, it is a highly reliability device  provides the fast error detection and keeps the non-stop connections 24 hours a day, 365 days a  year. To manage the Mana
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual        Recovery Time Setting    Recovery Time (Cyber-Ring Protocol): : : :  Recovery time is the duration of connections that from failure occurred to return to normal.  This function allows you to assign the recovery time in millisecond (ms), the variable is from  100ms to 1500ms (1.5 sec).   Factory default is 300ms.  On Cyber-Ring Protocol Mode, user can specify the recovery time manually, and the  Managed Switch will calc
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual       Forward Time (STP Protocol): : : :  Forward delay is the duration time that packages from pre-forwarding state to forward state.  Factory default is 10000ms, the variable is from 4000ms to 30000ms (30 sec). Setting is only  available on STP Mode.    Maxage Time (STP Protocol): : : :  Max age time is the interval that node Switches waiting for hello messages from the Master  Switch. It’s 6000ms by factory default, and the va
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual       4. Port configuration     Mirror   Mirror Port setting is commonly used to monitor the network traffic, it can help you to collect and  trace abnormal packets of each port without interrupting data transmission.    User can specify a switch port to receive the packet copies  which from another port.    STEP 1  Specify a “Monitor Port” that you want to get the packet  copies.    STEP 2  Specify the ports will be monitore
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual        Trunking   This function is used for setting the groups of link aggregation. Port trunking allows user to  combine multiple physical ports into a single logical channel. It can increase the link speed and  provide the better redundancy availability.  Supported groups depend on the total number of switch ports on the equipment.  508 Series Managed Switch supports up to 4 trunking groups.    NOTE!!  Active trunking funct
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual     Port   Port Number  Speed  Port transmission speed.(10 Mbps/100 Mbps)  Duplex  Flow Control Mode. Both Half-duplex and Full-duplex modes are supported.  Link  Port Link status. ON : Link is up ;  OFF : Link is down.     Cable Checking   This function provides a useful tool to detect the quality of cables.   Tick the checkbox of Ports and click “Start Check” button, after a moment waiting, system will  report the RX and TX
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual       5. Relay Alarm  Managed Switch offer a relay contact output on Terminal Block of the Switch equipment. It is able  to connect to a light, buzzer …etc. warning device and notify system failures immediately.  We also offer the web tool to configure the relay manually. It’s convenient for you to  enable/disable relay warnings since the Switch equipments are far from you.     Relay Output   This function enables you to conf
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual       6. Email Alarm  ICPDAS Managed Switch can notify you by email when the specified event occurred.  This chapter will guide you how to setting the related parameters.      Alarm Event setting  User can specify system and port events that warning emails will be sent.      Power1 ON The status of power1 from OFF turns to ON.  Power2 ON The status of power2 from OFF turns to ON.  Power1 OFF The status of power1 from ON turns
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual      Email Setting   User can select “Disable Alarm Mail” to stop the email alarm sending (factory default).  If email alarm is enabled, there are two methods of email report for you select.  The first one is: warning mail is sent immediately when events occur.  The second is: user can specify the interval time between 1 to 99 hour(s), and system will  sending the system report by email every the specified hour(s).      Befor
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        Industrial Ethernet Layer 2 Managed Switch – Web Management Manual      Email Record   Switch Management can keep the sending date, time and status of each warning emails.  But only the latest 50 sending records will be saved.  User can click the “Clean Record Table” button to delete all the email sending history.            April 29, 2008  17