Inhaltszusammenfassung zur Seite Nr. 1 
                    
                         
Mini Carpet Extractor (4 Gallon) 
MODELS: MPRO 
10080390 
 
MPROEU 
10080400 
 
MPROGB 
10080410 
 
MPROAU 
10080420 
 
 
 
Operating Instructions  (ENG) 
86037780-U 
 
08/15/08 
 
  
                                                                                                                                                                                                                                                                                                                          
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        MACHINE DATA LOG/OVERVIEW            Model:        Date of Purchase:       Serial Number:      Sales Representative:        Address:       Phone Number:    Copyright 2006 Windsor Industries, Printed in USA          OVERVIEW      This carpet extractor is a mains powered, portable carpet extractor intended for commercial use.   The appliance sprays a cleaning solution onto the carpet, agitates the wet carpet, and then  extracts the soiled solution back into the unit’s recovery tank.  The appliance
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        TABLE OF CONTENTS        Machine Data Log/Overview.........................2  PARTS LIST  Table of Contents..........................................3      Brush Deck ....................................... 5-1  HOW TO USE THIS MANUAL Control Panel.................................... 5-3  Decal.................................................5-5     Frame & Wheels............................... 5-7  How to use this Manual.................................1-1  Handle ..............................
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        HOW TO USE THIS MANUAL    This manual contains the following sections: The SAFETY section contains important information   regarding hazardous or unsafe practices of the  - HOW TO USE THIS MANUAL machine. Levels of hazards are identified that could  - SAFETY result in product damage, personal injury, or severe  - OPERATIONS injury resulting in death.  - MAINTENANCE   - PARTS LIST The OPERATIONS section is to familiarize the   operator with the operation and function of the  The HOW TO USE THIS M
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        SAFETY     IMPORTANT SAFETY INSTRUCTIONS  When using an electrical appliance, basic precaution  must always be followed, including the following:  READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.  This machine is for commercial use.    To reduce the risk of fire, electric shock, or injury:  Connect to a properly grounded outlet. See Grounding Instructions.  Do not leave the machine unattended. Unplug machine from outlet when not in use and before maintenance or  service.  Use only indoors. Do no
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        SAFETY    The following symbols are used throughout this guide as indicated in their descriptions:     HAZARD INTENSITY LEVEL  There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR  SAFETY. The level of hazard intensity is determined by the following definitions:        WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.        CAUTION - Hazards or unsafe practices which could result in minor personal injury or
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        SAFETY      120 VOLT MODELS:  THIS PRODUCT IS FOR COMMERCIAL    USE ONLY.  This appliance is for use on a nominal 120-volt    circuit, and has a grounded plug that looks like the  ELECTRICAL:  plug in “Fig. A”.  A temporary adaptor that looks like  In the USA this machine operates on a standard 15  the adaptor in “Fig. C” may be used to connect this  amp 120V, 60 hz, A.C. power circuit. The amp,  plug to a 2-pole receptacle as shown in “Fig. B”, if a  hertz, and voltage are listed on the data la
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        SAFETY    SAFETY LABEL LOCATION    The following WARNING LABEL(S) are found on your cleaning unit. These labels point out important Warnings  and Cautions which should be followed at all times. Failure to follow warnings and cautions could result in fatality,  personal injury to yourself and/or others, or property damage. Follow these instructions carefully! DO NOT  remove these labels.    NOTE:  If at any time the labels become illegible, promptly replace them.                  WARNING LABEL PA
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        OPERATION        CHEMICALS  To avoid electric shock    use indoors only.  Use only the suitable chemicals listed below. Using  To reduce risk of fire, do not use volatile substances.  incompatible chemicals will damage the machine.  Use only cleaners intended for carpet application.  Damages of this type are not covered under    warranty. Carefully read ingredients on  INSPECTION  manufacturer’s label before using any product in this  Carefully unpack and inspect your extractor for  machine.  sh
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        OPERATION  5 1 4 2 11 10 12 3 9 13 6 7 8             CONTROLS & COMPONENTS  7. Solution Tank Drain Hose      8. Accessory Tool Connection   1. Power and Operation Mode Switch         Solution connection for accessory tools.        Turns accessory tool on or machine on.      9. Accessory Hose Connection  2. Main Handle        Hose connection for accessory tool.      3. Solution Button   10. Dome Clamp        Sprays solution on floor when pressed.      11. Dome  4. Brush Motor Circuit Breaker     
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        OPERATION  OPERATING INSTRUCTIONS       FILLING THE SOLUTION TANK  SPECIAL NOTES:       1. Release dome clamp.  This appliance is not intended for use by persons    (including children) with reduced physical, sensory   2. Lift upper recovery tank from machine and   or mental capabilities, or lack of experience and   set aside.  knowledge, unless they have been given supervision    or instruction concerning use of the appliance by a  3. Use a clean bucket, recovery tank or hose to  person respons
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        OPERATION        OPERATING THE MACHINE  OPERATING MACHINE WITH     1. Vacuum the carpet and make sure it is cleared  ACCESSORY TOOLS   of surface debris before cleaning.      This extractor is easily adapted for use with Windsor  2. Plug power cord into a grounded wall outlet.  accessory tools:  Contact Customer Service for details.     1. Disconnect vacuum hose at dome, insert hose cuff  NOTE: Defeating the grounding pin on the power  cord can result in a severe electrical shock. into the dome,
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        MAINTENANCE     PROTECT FROM FREEZING PERIODIC MAINTENANCE     If it becomes necessary to store in temperatures that 1. After every 25 hours of operation, flush a white  could drop below 40°F, the pumping system, hoses   vinegar solution (ONE quart vinegar to two  and valves must be protected from freezing with a  gallons of water) or anti-browning solution (mixed  methyl hydrate window washer antifreeze solution.  as directed) through the extractor.  This will    prevent build-up of alkaline re
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        MAINTENANCE      MAINTENANCE INSTRUCTIONS  SPRAY JET         Remove machine power  Note: To prevent a clogged jet due to alkali build-up,  cord from electrical source  the spray system should be flushed with 1 to 2  before making any adjustments or repairs to the  gallons of clean hot water at the end of each day.   machine.      1. Turn off switch and unplug machine.  Only qualified maintenance    personnel are to perform    2. Position the machine to have access to the                         
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        MAINTENANCE      PUMP REMOVAL  BRUSH MOTOR REMOVAL      1. Turn off switch and unplug machine.  1. Turn off switch and unplug machine.      2. Set the machine in its upright position.  Remove  2. Set the machine in its upright position.  Remove  the screws (2) in the back metal cover.  Rotate  the screws (2) in the back metal cover.  Rotate  the cover down and slide back releasing the tab  the cover down and slide back releasing the tab  under the machine from the main frame.  under the machine 
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        MAINTENANCE      VACUUM MOTOR REMOVAL   Vacuum Motor Carbon Brushes Replacement      End Cap  1. Turn off switch and unplug machine.        2. Set the machine in its upright position.  Remove  WARNING: The green    Carbon  the screws (2) in the back metal cover.  Rotate ground wire must be  Brushes    attached for safe operation.  the cover down and slide back releasing the tab    See wiring diagram.  under the machine from the main frame.        3. Remove the pump box cover.  Remove screws    (
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        MAINTENANCE    TROUBLESHOOTING CHART  PROBLEM CAUSE SOLUTION  Is the cord plugged in. Plug in cord.  No power, nothing runs  Circuit breaker tripped in building. Reset breaker  Faulty switch. Call for service.  Faulty power cord or pigtail. Call for service.   Vacuum circuit breaker tripped. Reset breaker  Vacuum motor will not Faulty main switch. Call for service.  run  Loose wiring. Call for service.  Faulty vac motor.    Call for service.   Debris lodged in vac shoe. Remove debris from vac sh
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        MAINTENANCE      TROUBLESHOOTING CHART  Squealing or grinding sound in brush  Worn brush bearings Replace bearings.  housing.  Make several passes at right angles to  Carpet not getting clean Severe soil conditions each other.  Use a pre-spray.  Replace spray jet which is producing a  Worn spray jet  Carpet too wet  fine mist.  Clean solution filter screen located  Solution filter screen clogged.  inside lower tank.  Clean or replace jet.   Do not use a wire  Spray jet clogged. to clean jet.  Da
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                            Mini Carpet  Extractor  Parts List  86037780  EXTRACTOR 12/09/06                                                                                                                                                                                                                                                                                                                                                                                                                                                
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        BRUSH DECK              2 1 3 15 16 8 9 10 11 4 13 5 1 7 6 12 1 7 14 86037780  EXTRACTOR 03/27/07  5-1