Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        English
Set & $a Set & $a Set & $av v ve e e
Programmable Thermostat
installation and
operation manual
Model
44155c
Form# 42708-01
20091111
©2009 Hunter Fan Co.
1                                                                                                                                                                                                                                                                                                                                                  
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        2                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        Table of Contents Important Information....................................... 5 Tools ................................................................ 6  Uninstalling the Existing Unit ........................... 7  Installing the Thermostat ............................... 12 installing the wall plate ................................ 12 connecting the wires ................................... 16 attaching the thermostat ............................. 18 Settings .................................
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        Set & Save  Set & Save  Programmable Thermostat Programmable Thermostat Model 44155C Model 44155C Congratulations! Thank you for choosing a Hunter programmable  thermostat. Your new Hunter thermostat will  provide years of reliable service and year-round  energy savings.  Please read this manual before beginning  installation and save this booklet for complete  operation instructions.  4                                                                                                              
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                         iMporT anT inforMa Tion This thermostat is designed to work on the following  heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – Fired Boilers Gas – Milivolt Systems Oil – Fired Boilers Oil – Fired Furnace Electric Furnace Electric Air Conditioning Single Stage Heat Pump - No auxilary This thermostat is not designed for multi-stage heat  pump systems or 110/220 V baseboard heating  systems.   If you are unsure what kind of heating and cooling  system you have, ple
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        ToolS This thermostat includes two #8 slotted screws  and two wall anchors for mounting. To install your new thermostat, you will need the  following supplies: Flat-head screwdriver .................................................................................... Small Phillips-head screwdriver .................................................................................... Hammer .................................................................................... Electric drill and 3/16”
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        noTiCE! Do not disconnect the  wires from the existing thermostat  before reading these instructions.  The wires must be labeled prior  to removal to ensure proper  reconnection.  7                                                                                                                                                                                                                                                                                                                               
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        8 W RC Y G W RC Y G                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        uninST alling ThE ExiSTing uniT 1. Turn the system power OFF from the existing  thermostat. Turn the power to the HVAC  system OFF at the main power panel or at  the furnace.  2. Remove the existing thermostat cover to  access the wires from the wall.   (Some thermostats may have multiple covers, screws  or other locking devices that must be removed or  disengaged.)  3. Locate, but do not disconnect the wires.   (If wires are not visible, they may be connected to the  back of the wall plate. Som
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        if your existing label the wire  thermostat is marked... with this sticker: RH / R / VR / 4 24 Volt RH RC / VC 24 Volt cool RC air conditioning  Y / C* / M / O compressor Y/0 W / H / B heating W/B G / F fan G heat pump  Y1 compressor Y1 10 G RC RH Y W Y1 G W/B Y/0 RC RH                                                                                                                                                                                                                                      
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        W uninST alling ThE ExiSTing uniT , ConT . 4. Using the provided stickers, label each wire  according to the chart.                 (If the terminals are not labeled, contact  a qualified HVAC technician.)  note: Wire colors do not always comply  with standards, so wire color should be  ignored. refer to the existing terminal  designation for proper identification.  *If wires marked Y & C are both present, C may  be a Common wire and should not be used. If  you have a wire marked C, do not conne
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        G 12 Y RC W                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        inSTalling ThE ThErMoST aT inSTalling ThE W all pla TE 1. Remove the wall plate from the new  thermostat by pressing the release tab on the  bottom of the thermostat.  2. Position the new wall plate on the wall and  pull the labeled wires through the opening.  3. If the existing holes do not match those  on the Hunter wall plate, or if there are no  existing holes, visually level the wall plate  and mark the wall for two holes.  13                                                                 
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        G 14 Y RC W                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        inSTalling ThE ThErMoST aT, ConT . 4. Remove the wall plate and drill two 3/16”  holes where marked.  5. Tap the plastic anchors into the holes until  they are flush with the wall.  6. Reposition the wall plate on the wall, pulling  the wires through the opening. Insert the  mounting screws through the wall plate and  into the anchors. Verify that the wall plate  is visually level and securely tighten both  screws.  15                                                                              
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        G RCRH Y1 G Y/0W/B Terminal Shield 16 RC Y1 W/B Y/0                                                                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        inSTalling ThE ThErMoST aT, ConT . ConnECTing ThE WirES 1. Loosen, but do not remove, the terminal  screws.  note: a jumper wire has been provided,  Jumper connecting the rC and rh terminals for  systems that do not provide both an rh  G RC RH Y W and rC wire. if you have both an rh and rC  wire, remove this jumper. if you do not have  both an rh and rC wire, leave the jumper in  place.  2. Match and connect the wires from the wall  to the terminals as shown. Wires should be  inserted behind the
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        Thermostat  T AM 4 Cover HEAT ENABLE RECOVERY DISABLE System  Switch STD HP SYSTEM  TYPE HG HE FAN OPTION Y1 G RC W/B Y/O RH Y/O RH W/B RC Y1 G 18                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                        inSTalling ThE ThErMoST aT, ConT . aTTaChing ThE ThErMoST aT Lift the thermostat cover and set the SYSTEM sh to ctiw OFF  and the FAN switch to AUTO.  1. Locate the HE/HG s hctiw on the back of the thermostat.  Set the switch to HG (default) for gas furnace and oil  burners. Set the switch to HE for electric furnaces.    (The switch has no effect when the system is set to  cooling mode.)  2. Locate the Ao Re tu y switch on the back of the revoc thermostat. If you wish to use the Auto Recovery  f
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        1 Tab 2 20