Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        BLUE FLAME VENT-FREE PROPANE/LP GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
MODELS REM10PT AND RH10PT
10,000 Btu/Hr Thermostatically-Controlled Heater
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable 
vapors and liquids in the vicinity of this or any other 
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any applian
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation  and operational procedures. For assistance or addi- tional information consult a qualified installer, service  agency or the gas supplier. WARNING: This is an unvented gas-fired heater. It uses  air (oxygen) from the room in which it is installed. Provi- sions for adequate combustion and ventilation air must  be provided. Refer to Ai
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        SAFETY INFORMATION  WARNING: If the recreational   WARNING: This product con- or commercial enclosure does  tains and/or generates chemicals not have a window or roof vent,  known to the State of California DO NOT USE THIS HEATER  to cause cancer or birth defects inside. or other reproductive harm. This heater should be inspected  IMPORTANT: Read this owner’s before each use. Frequent clean- manual carefully and completely ing may be required. The control  before trying to assemble, compartments
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        11. Do not use heater if any part has been under  SAFETY INFORMATION water. Immediately call a qualified service  Continued technician to inspect the room heater and to  1. Install and use heater with care. Follow all  replace any part of the control system and any  local ordinances and codes. In the absence  gas control which has been under water. of local ordinances and codes, refer to the  12. Turn off and let cool before servicing. Only  Standard for Storage and Handling of Lique- a qualified 
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        The amount of propane/LP gas ready for use from  PRODUCT  propane/LP tanks varies. Two factors decide this  IDENTIFICATION amount: Ignitor Button Control  1. The amount of propane/LP gas in tank(s) Knob 2. The temperature of tank(s) This heater is designed for use with a 20 or 40  Heater  pound refillable propane/LP cylinder when used  Cabinet as a self contained heating system (with hose and  regulator). Larger tanks may be used if installed  in a permanent gas supply system. The propane/LP cyli
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        THERMOSTAT SENSING BULB INSTALLATION The thermostat sensing bulb is located inside the  Continued heater. Do not move this bulb during installation  or operation of the heater.  CAUTION: This heater cre- INSTALLING HEATER TO WALL ates warm air currents. These  currents move heat to wall sur- Marking Screw Locations 1. Determine where you will locate heater. faces next to heater. Installing  heater next to vinyl or cloth wall   WARNING: Maintain mini- coverings or operating heater  mum clearances
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        Removing Front Panel Of Heater INSTALLATION 1. Remove two screws near bottom corners of  Continued front panel. 3. Insert wall anchor (wings first) into hole. Tap  2. Lift straight up on grill guard until it stops.  anchor flush to wall. Grill guard will slide up about 1/4". 4. For thin walls (1/2" or less), insert red key  3. Pull bottom of front panel forward, then  into wall anchor. Push red key to “pop” open  down. anchor wings (see Figure 5).  I M P O R T A N T : Do not hammer key! For thick 
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        places the regulator vent in the proper position  INSTALLATION to protect it from the weather. Continued 6. Connect hose to heater inlet. Tighten firmly  CONNECTING TO PORTABLE  using a wrench. You must use the regulator  CYLINDER GAS SUPPLY supplied with heater. 7. Open propane/LP supply valve on propane/LP  tank(s) slowly. N o t e : If not opened slowly,   WARNING: Review and un- excess-flow check valve on propane/LP tank  derstand the warnings in the  may stop gas flow. If this happens, close pr
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        INSTALLATION  CAUTION: Use only new,  Continued black iron or steel pipe. Inter- nally-tinned copper tubing may   CAUTION: Never connect heater  be used in certain areas. Check  directly to the propane/LP supply.  your local codes. Use pipe of  This heater requires an external  large enough diameter to allow  regulator (not supplied). Install  proper gas volume to heater. If  the external regulator between the  pipe is too small, undue loss of  heater and propane/LP supply. volume will occur. In
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        Test Pressures Equal To or Less Than  INSTALLATION 1/2 PSIG (3.5 kPa) Continued 1. Close equipment shutoff valve (see Figure 14). CHECKING GAS CONNECTIONS  2. Pressurize supply piping system by either  FOR PERMANENT GAS SUPPLY opening propane/LP supply tank valve or  using compressed air.  WARNING: Test all gas piping  3. Check all joints from supply tank to equip- and connections, internal and ment shutoff valve (see Figure 15). Apply a  noncorrosive leak detection fluid to all joints.  external
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        OF F HI 6. Turn control knob counterclockwise   OPERATING HEATER to the PILOT position. Press in control  FOR YOUR SAFETY READ knob for five (5) seconds. 7. With control knob pressed in, push down  BEFORE LIGHTING and release ignitor button. This will light  pilot. The pilot is attached to the front of   WARNING: If you do not fol- burner. Note: You may be running this  low these instructions exactly,  heater for the first time after hooking up to  a fire or explosion may result  gas supply. If so,
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        OPERATING HEATER INSPECTING HEATER Continued Check pilot flame pattern and burner flame pat- tern often. TO TURN OFF GAS  PILOT FLAME PATTERN TO APPLIANCE Figure 18 shows a correct pilot flame pattern.  Shutting Off Heater 1. Turn control knob clockwise  to the Figure 19 shows an incorrect pilot flame pattern.  The incorrect pilot flame is not touching the  OFF position. thermocouple. This will cause the thermocouple  2. Turn off all electric power to the appliance  to cool. When the thermocouple co
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        e a so eco end ha you keep he bu ner  W l r mm t t   t r INSPECTING HEATER tube and pilot assembly clean and free of dust and  Continued dirt. To clean these parts we recommend using  compressed air no greater than 30 PSI. Your local  computer store, hardware store or home center  1/2 GLASS HEIGHT may compressed air a can. ou a  carry in Y can use  1/2 GLASS HEIGHT vacuum cleaner in the blow position. If using com- CORRECT FLAME PATTERN pressed air in a can, please follow the directions on  AT H
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        TROUBLESHOOTING  WARNING: Turn off and unplug heater and let cool before servicing.  Only a qualified service person should service and repair heater.  CAUTION: Never use a wire, needle or similar object to clean  ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed, 1. Ignitor electrode positioned wrong 1. Replace pilot assembly there is no spark at ODS/pilot 2. Ignitor e
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after ODS/ 1. Burner orifice is clogged 1. Clean burner (see Cleaning  pilot is lit and Maintenance, page 13)  or replace burner orifice 2. Inlet gas pressure is too low 2. Contact local propane/LP gas  company Delayed ignition of burner 1. Manifold pressure is too low 1. Contact local propane/LP gas  company 2. Burner orifice is clogged 2. Clean burner (see Cleaning  and Maintenance, page 13)  or replace burner 
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        TROUBLESHOOTING Continued  WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your  building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPOR T ANT : Operating heater where impurities in air exist may create odors. Cleaning supplies,  paint, paint remover, cigarette smoke, c
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        STORAGE TECHNICAL SERVICE You may have further questions about installation,   CAUTION: Disconnect heat- operation or troubleshooting. If so, contact DESA  Heating Productsʼ Technical Service Department  er from propane/LP supply  at 1-866-672-6040. When calling please have your  tank(s). model and serial numbers of your heater ready. When the propane/LP supply cylinder is not dis- You can also visit DESA Heating Productsʼ techni- connected from the heater, the heater and the cyl- cal service we
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        ILLUSTRATED PARTS BREAKDOWN MODELS REM10PT AND RH10PT 22 21 20 10 14 19 16 13 12 10 4 18 1 1 9 14 15 7 17 6 3 1 5 8 2 1 Pilot 18 www.desatech.com 110373-01E                                                                                                                                                                                                                                                                                                                                                        
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                        PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions  listed under Replacement Parts on page 17 of this manual. KEY  NO. PART NO. DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" • • 2 2 099467-09 Front Panel Assembly • 1 099467-10 Front Panel Assembly • 1 3 099318-04 Grill Guard • • 1 4 101108-01 Grill Guard Clip • • 2 5 102017-02 Bottom Glass Retainer • • 1 6 098260-11 Glass Panel • • 1 7 099319-02 Top Glass Retainer • • 1 8 110701-01 
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date of Purchase Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our  standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTIES FOR NEW AND FACTORY  RECONDITIONED PRODUCTS New Products: DESA Heating Products warrants this heater and any parts thereof, to be free of d