Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        ULTRA FLAME 
DIRECT VENT "0" CLEARANCE GAS FIREPLACE 
 
 
 
INSTALLATION AND OPERATING INSTRUCTIONS 
 
 
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE 
OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO 
THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT 
A QUALIFIED INSTALLER, SERVICE AGENCY, OR THE GAS SUPPLIER. 
 
 
FOR YOUR SAFETY 
 
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND 
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. 
 
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   TABLE OF CONTENTS    GENERAL INFORMATION................................................................................................. 3  WARNING ............................................................................................................................... 4  SPECIFICATIONS..................................................................................................................5  OPERATION ......................................
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace    GENERAL INFORMATION    The ULTRA FLAME DIRECT VENT GAS FIREPLACE is a high-efficiency free-standing   gas appliance with a maximum  input rating of 30 000 Btu/h with natural gas or 26,000 Btu/h  with propane. It features a thermostatic modulating valve and a constant pilot.  This means that  you can set the height of the flame to your liking by turning the adjusting knob. An optional  thermostat is also available for automatic room temperature control. T
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   WARNING      INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER.    DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THIS APPLIANCE.    HOT WHEN IN OPERATION. KEEP CHILDREN, FURNITURE, CLOTHING AND  FLAMMABLE MATERIAL AWAY FROM THE APPLIANCE.     ADVISE ADULTS AND CHILDREN ABOUT THE HAZARD OF HIGH SURFACE  TEMPERATURES AND THAT THEY SHOULD STAY AWAY TO AVOID BURNS OR  CLOTHING IGNITION.    YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME  ROOM AS 
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   SPECIFICATIONS     Dimensions:  height 39", width 36", depth 20"     o Glass:    29-1/8" x 17-3/4" 1400 F clear ceramic    Minimum opening in wall for installing the units:      height:  39-1/2"      width:  36-1/2"      Fuel:    Natural Gas         Propane   Input :    30,000/ 20,000        26,000/20,000  Btu/h   Manifold pressure :  3.5/1.8          10.5/7.0     in w.c.   Min. inlet pressure :   5          11              in w.c.   Max. inlet pressure :
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   OPERATION    BEFORE LIGHTING    1) Do not use this appliance if any part has been under water.  Immediately call a qualified  service technician  to inspect the appliance and to replace any part of the control system and  any gas control which has been  under water.     2) Make sure that there are no obstructions in the air intake or venting system.     3) Clear the immediate area of combustible materials, gasoline, and other flammable liquids and  vapour
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace      • Press gas control knob in and hold.  Immediately push the red igniter button repeatedly until  pilot flame ignites.  Continue holding in the control knob for 5 to 10 seconds, then release it.   If the pilot flame goes out, repeat this step.     • Push and turn gas control knob counterclockwise  to the "on" position.     CAUTION:  This fireplace is hot while in operation.  Do not touch.  Keep children, clothing  and flammable materials away.    WALL  
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   MAINTENANCE INSTRUCTIONS    TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE  ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.    The venting system and the gas fireplace should be inspected at least once a year.    Remove the glass front and the logs and clean them if necessary.    The control compartment, air circulating passages, firebox, logs and burner should be cleaned at  least once a year by vacuuming or brushing.    Check the pilot fla
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   BURST DISC REPLACEMENT    If the burst disc under the burner moves from its location, it must be put back in place into the  silicone seal.  Make sure the switch is depressed all the way during the installation.  Otherwise  the appliance will not operate.    WARNING:  Never glue or lubricate the disc to the silicone seal.  Do not put any object under  the disc.         9                                                                                      
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   TOP, FRONT AND SIDE VIEWS           FRONT VIEW      TOP VIEW                                         SIDE VIEW  .......................................................................................................................................................................................................   10                                                                                                                                               
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   INSTALLATION    SAFETY NOTICE    Improper installation may result in a house fire. Follow installation directions.  Installation must  be in accordance with local building codes or, in the absence of local codes, with current  CAN/CGA B 149 installation codes for gas appliances in Canada and current National Fuel Gas  Code ANSI Z223.1 in the USA.    INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER.    THIS GAS FIREPLACE MUST BE VENTED OUTSIDE.    THIS
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   VENT TERMINAL LOCATION     Your Ultra Flame fireplace vents through a vent terminal installed on the roof or on the outside  of any exterior wall of your house. Many restrictions apply to the vent terminal location that  should be considered before locating your fireplace.     The following drawing presents a summary of most of these restrictions.        A = 12" Clearance above grade, veranda, porch, deck or balcony  B = 12" Clearance to window or door th
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   J = 12"  Clearance to non-mechanical air supply inlet to building or the combustion air inlet  to  any other appliance  K = 72" Clearance to a mechanical air supply inlet  L = 84"  Clearance above paved sidewalk or a paved driveway located on public  property  M =36"  Clearance under veranda, porch, deck, or balcony      A vent shall not terminate directly above a sidewalk or paved driveway which is located  between two single family dwellings and serves 
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace      Top of fireplace (spacer)   0"   Back of fireplace    0"   Sides of fireplace    0"   Bottom of fireplace    0"   Vent pipe:     2"   Wall perpendicular to the standard   surround     1/2"   Mantel (from upper part of the    standard surround)    6" if the projection is up to 6"          12" if the projection is over 6"    NOTE: If you install decorative posts to support the mantel shelf, they can be  located  1/2"  away from the side of the fireplace 
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace       • Check the gas line piping for leaks. Use a soap and water solution.      WARNING: DO NOT USE OPEN FLAME TO CHECK LEAKS.    You are now ready to proceed to the venting kit installation.     15                                                                                                                                                                                                                                                                      
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   VENTING KITS                 STRAIGH OUT    CORNER           RADIATION SHIELD 10-1/2" X 10-1/2" OPENING 29-1\2"FOR STRAIGHT OUT "K" CUT TO LENGTH 39-1\4" FOR CORNER INSTALLATION KIT            BASEMENT     THROUGH THE WALL DETAIL       16                                                                                                                                                                                                                             
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   Once the position of the fireplace and the termination cap are fixed, you should select the  venting kit appropriate for your needs. First floor installations require either a STRAIGHT OUT  kit or a CORNER kit while basement installations must be done with a BASEMENT kit.  Please  note that the BASEMENT kit can also be used on first (or higher) floors and it is possible to use  up to 25' of pipe with a distant installation.    1) STRAIGHT OUT INSTALLATION
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   • Add a spring spacer.  The spring spacer must be located opposite the outside pipe joints to  prevent puncturing of the inside pipe when the two sections of the outside pipe are screwed  together.  • Slip on the 90° x 8" elbow so that it faces your hole in the wall.  Seal it with silicone and  secure with screws.  • Add a spring spacer.  • Add sections of 8" diameter pipe and cut it to be flush with the outside face of the exterior  wall, and install the
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace      VENTING SYSTEM         19                                                                                                                                                                                                                                                                                                                                                                                                                                               
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        ULTRA FLAME DV “0” Clearance Fireplace   VENT TERMINAL, STRAIGHT OUT AND CORNER INSTALLATION    Seal with RTV silicone between 8" diameter pipe and radiation shield inside and outside the  building to prevent air passage.  Install the vent terminal as shown.  Insert the wall plate inside  the 8" pipe and screw it to the wall using the six #10 2-1/2" wood screws supplied.  Place the 5"  locking band  around the inner connector and insert the exhaust pipe.  Seal the joint with RTV  silicone.  Secu