Inhaltszusammenfassung zur Seite Nr. 1 
                    
                         
EXCEL-FIRE 
VENTED GAS STOVE 
INSTRUCTIONS MANUAL 
 
 
 
 
 
 
WHAT TO DO IF YOU SMELL GAS: 
WARNING: If the information in these 
instructions is not followed exactly, a fire or 
explosion may result causing property 
• Do not try to light any appliance. 
damage, personal injury or loss of life. 
• Do not touch any electric switch; do not use 
any phone in your building. 
FOR YOUR SAFETY: Do not store or use 
gasoline or other flammable vapours and • Immediately call your gas supplier from 
l
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        EXCEL-FIRE GAS STOVE 1    TABLE OF CONTENTS  GENERAL INFORMATION......................................................................................................................... 2  WARNING................................................................................................................................................... 2  TECHNICAL SPECIFICATIONS................................................................................................................. 3  Burner......
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        EXCEL-FIRE GAS STOVE 2  GENERAL INFORMATION  The EXCEL-FIRE gas stove is a high-efficiency free-standing gas appliance with a maximum input  rating of 30 000 BTU/h (8,8 kW) with natural gas or 26 000 BTU/h (7,6 kW) with propane. It  features an adjustable millivolt valve and a constant pilot. This means that you can set the height of  the flame with a control knob. An optional wall thermostat is also available for automatic room  temperature control. The valve is also independent of any exterior
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        EXCEL-FIRE GAS STOVE 3  TECHNICAL SPECIFICATIONS  Dimensions  • Height : 29 ¾ in. 756 mm  • Width : 24  in. 610 mm  • Depth : 20 in. 508 mm  Glass   18 ½ in. x 10 ½ in.   470 mm x 267 mm  Weight 140 lbs 64 kg  Colour metallic black  Flue pipe "B-Vent" ou "L-Vent"   ∅ 4 in. (100 mm)  Clearance to combustibles  • Back: 4 in. 102 mm  • Side: 8 in. 204 mm  • Corner: 2 in. 50 mm  • Ceiling: 48 in. 1228 mm    Note 1 • Floor: Combustible   Note 1 : Your stove has been successfully certified while insta
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        EXCEL-FIRE GAS STOVE 4  Burner   Naturel Gas Propane LP  Maximum Input, BTU/h (kW) minimum :  20 000 (5,9)   20 000 (5,9)   maximum :  30 000 (8,8)  26 000 (7,6)  Inlet Pressure INWC (kPa) minimum :  5,0 (1,3)  11,0 (2,8)   maximum :  7,0 (1,8)  14,0 (3,5)  Manifold Pressure INWC (kPa) minimum :  1,8 (0,5)  7,0 (1,8)   maximum :  3,5 (0,9)  10,0 (2,5)  #36 DMS #52 DMS  Burner orifice ∅ :  Injecteur du pilot  ∅ : #51 DMS #30 DMS  Air Shutter opening (in.) 1/4  open  full open  Gas Valve SIT 820 N
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        EXCEL-FIRE GAS STOVE 5  INSTALLATION  Safety notice  • Improper installation may result in a house fire. Follow installation directions.  Installation must be in accordance with local building codes or, in the absence of local  codes, with current CAN/CGA B 149 installation codes for gas appliances in Canada and  current National Fuel Gas Code ANSI Z223.1 in the USA.  • Installation should be done by a qualified installer.  • This gas stove must be vented outside.  • When installed with optional
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        EXCEL-FIRE GAS STOVE 6    For clearance between pipe and flammable materials, follow vent pipe manufacturer’s  instructions.  Logs installation                                                                                                                                                                                                                                                                                                                                                                     
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        EXCEL-FIRE GAS STOVE 7  1. Remove the two door retaining screws at the bottom right and left of the door.  2. Remove the door.  3. Locate the log grate in the retainers in the right and left rear corners.  4. Place the rear log (1) against the rear log stop. Make sure grooves at the back of  the log line  up with the grates log stop.  5. Place logs 2 and 3 against the stops in the middle of the grate. Again see that grooves in the  the logs line up with the grates log stop.  6. Place log 4 into 
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        EXCEL-FIRE GAS STOVE 8     DISTANCE DIAMETRE   20 pi 18GA   30 pi 16GA   40 pi 14 GA   50pi 12GA  REMOVE THE BLUE JUMPER BETWEEN TP & TPTH SCREWS ON THE GAS VALVE.  Optional blower  The blower control contains a variable speed switch and a thermal switch. When the stove is  operating, the thermal switch will turn on at 110° F, allowing the blower to operate. When the stove  cools to 90° F, the thermal switch turns off the blower in about 40 minutes.  This prevents the  blower from operating when
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        EXCEL-FIRE GAS STOVE 9  Gas connection  • Move the EXCEL-FIRE to the desired  position and secure in place with four screws. • Connect gas line to the stove using listed  connectors  • Check the gas line piping for leaks. Use a  soap and water solution.   WARNING: DO NOT USE OPEN FLAME TO  CHECK LEAKS.      Spill switch  The EXCEL-FIRE is fitted with a spill switch. This switch is designed to shut down the unit if the  flue system is not venting properly. This is usually due to negative pressure
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        EXCEL-FIRE GAS STOVE 10  1. Open the pedestal front panel to reach the control.  2. Make sure the gas control knob is turned to the ‘’OFF’’ position. If it is not, press knob slightly  and turn clockwise  to the "OFF’’ position.  Do not force the gas control knob. If the gas  control was in the on position you should wait 5 minutes before trying to re-light the stove.  3. If you smell gas STOP and follow instructions on the COVER page.  4. Push in and turn gas control knob counterclockwise  to t
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        EXCEL-FIRE GAS STOVE 11  If Your Glass Breaks:  • See your dealer for exact replacement glass.  • Remove front as explained above. With a 5/16” nut driver remove all nuts holding the glass  retainers.  Carefully remove retainers and seal.  • After removing all broken glass pieces, insert new glass and reinstall seal and brackets.  It the  seal is damaged, replace it with an identical new seal from your dealer (see replacement parts)  Glass door    Removal  • Let the stove cool down for at least 
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        EXCEL-FIRE GAS STOVE 12  Installation  • Put the burner assembly back in the fire box  and push to the right.  • Make sure the main orifice is inserted in the  ventury tube as shown. And screw the burner  back into place.  WARNING: Never operate the gas stove  without having the orifice properly inserted  in the venturi tube. This could result in  serious damage to the gas insert and is a  serious risk of fire.      Gas pressure adjustments  NOTE: Adjustments to the valve assembly must be perfor
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        EXCEL-FIRE GAS STOVE 13  Pilot assembly    Adjusting air shutter (Venturi)  The factory setting for the air shutter is 1/4” for natural gas, fuily open for propane. After operating  the appliance for half an hour or so the flames should have turned a nice yellow colour.  However,  in higher altitudes you may find a smudging up of the glass after a few days.  The shutter should  then be adjusted open in 1/16” increments until the glass stays clear.  If the flame does not turn  yellow the air shut
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        EXCEL-FIRE GAS STOVE 14    1700, rue Léon-Harmel, Québec (Québec) G1N 4R9  tel. : (418) 527-3060    fax : (418) 527-4311  e-mail : tech@drolet.ca    web site : drolet .ca  LIMITED WARRANTY  The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers  brand new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of purchase (dated  bill of sale), model name and serial number must be