Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        Wood Burning Fireplace
oWner’S opera Tion and inST alla Tion Manual
PFS
®
C US
ICC-ES #ESR-2542
(V)gM36, (V)gM42 and  
(V)M50 Serie g S and W cM-36g , 
WcM-42g and W cM-50g
Wood Burning MaSonry 
FireplaceS WiTh inSula Tion
SAVE THIS BOOK
This book is valuable. In addition to instructing you 
on how to install and maintain your appliance, it also 
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep 
it with your other important papers.
This
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                         WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury, property  damage or loss of life. Refer to this manual for assis- tance or additional information. Consult a qualified  installer or local distributor. TaBle oF conTenTS Safety .................................................................. 2 Glass Door Installation ...................................... 29 Specifications ...................................................... 3 Operation and Ma
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        SpeciFica TionS 36" MODELS 29" 1 22 /2" 1 14 / " 2 22" 3 13 18 /8" 5 19 /16" 26 /8" (Ref.) 5 15 / " 8 3 35 /8" 5 1 1 /16" 4 /2" 36" HEARTH 11" OUTSIDE AIR 67" ACCESS 61" 58" 49" GAS LINE 30" ACCESS 1 10 /2" 1 9 /2" 7" 1" 1 3 /2" 1 36" 1 4 /2" 7 / " 4 1 1" 45 /8" 11" 1 15 /4" Figure 1 - 36" Models (V)GM36 Series and WCM-36G 122271-01D www.fmiproducts.com 3                                                                                                                                               
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        SpeciFica TionS Continued 42" MODELS 1 30 / " 2 3 22 / " 4 25" 3 15 /4" 1 22 /2" 13 23 /16" 29" (Ref.) 5 17 /8" 3 3 4 /8" 41 /8" 5 1 /16" 42" HEARTH 5/8" OUTSIDE  AIR 11" ACCESS 58" 67" 61" GAS LINE 49" ACCESS 30" 1 1 10 /2" 9 /2" 7" 1 3 /2" 1 8 /2" 42" 1 4 / " 2 1 1" 13" 51 /8" 17" Figure 2 - 42" Models (V)GM42 Series and WCM-42G 4 www.fmiproducts.com 122271-01D                                                                                                                                       
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        SpeciFica TionS Continued 50" MODELS 1 38 / " 2 24" 33" 1 19 /4" 13 23 /16" 1 22 /2" (Ref.) 1 28 /2" 5 17 / " 8 3 49 /8" 3 5 1 / " 4 /8" 16 50" HEARTH OUTSIDE  AIR 11"  ACCESS 67" GAS LINE 58" 49" ACCESS 61" 30" 1 10 /2" 1 9 /2" 7" 1 3 /2" 1" 1 1 50" 4 /2" 8 /2" 59" 13" 17" Figure 3 - 50" Models (V)GM50 Series and WCM-50G 122271-01D www.fmiproducts.com 5                                                                                                                                                
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        Fireplace inST alla Tion SELECTING LOCATION FRAMING 1. Frame opening for fireplace using dimen- To determine the safest and most efficient  sions shown in Figures 4 and 5. location for the fireplace, you must take into  consideration the following guidelines: 2. If fireplace is to be installed directly on  carpeting, tile (other than ceramic) or any  1. The location must allow for proper clear- combustible material other than wood  ances (see Figures 4 and 5). flooring, fireplace must be install
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        Fireplace inST alla Tion Continued HEARTH ExTENSION MANTELS A hearth extension projecting a minimum of A mantel may be installed if desired (see Figure  20" in front of and a minimum of 12" beyond  7). Woodwork such as wood trims, mantels or  each side of fireplace opening is required to  any other combustible material projecting from  protect combustible floor construction in front  front face must not be placed within 12" (36"  of fireplace. Fabricate a hearth extension  Models) or 18" (42/50"
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        VenTing inST alla Tion OPTIONAL OUTSIDE AIR KIT   WARNING: The opening in  (MODEL AK4/AK4F) the collar around the chimney at  The installation of an outside air kit should  the top of the fireplace must not  be performed during the rough framing of  the fireplace due to the nature of it's location. be obstructed. Never use blown  Outside combustion air is accessed through  insulation to fill the chimney  a vented crawl space (AK4F) or through a  enclosure. sidewall (AK4). LINEAL GAIN  CAUTION: C
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        VenTing inST alla Tion Continued Continue to assemble chimney sections as if properly locked. It is not necessary to add  outlined above, making sure that both the screws to keep the chimney together (excep- inner and outer pipe sections are locked to- tion, see Figure 10). gether. When installing double wall snap-lock  USING ELBOW OFFSETS (30E-12DM) chimney together, it is important to assure  1. To achieve desired offset, you may install  the joint between the chimney sections is  combinations
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        VenTing inST alla Tion Continued Return  Return  Elbow Elbow Return  Offset  Offset  Elbow Elbow Elbow 6' Max. 6' Max. Ceiling  Support Pipe Return  12S-12DM Return  6' Max. Elbow Elbow 6' Max. Offset  Offset  Elbow Elbow 6' Max. 6' Max. Offset  Elbow A B C Figure 12 - Typical Offset Terminations Screws or Staples  FIRESTOP SPACERS (FS-10,  Firestop  (Min. of 8) 1100EFS-10DM FOR 36" MODELS) Spacer Firestop spacers are required at each point  Existing  where the chimney penetrates a floor space. 
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        VenTing inST alla Tion Continued 5. Add next sections of pipe until end  FLASHING INSTALLATION (v6F-10DM  penetrates roof line. Check to see that  OR v12F-10DM) proper clearances are maintained. Extend  Determine the flashing to be used with the roof  chimney by adding sections of double wall  opening chart. Slide flashing over pipe until  pipe until pipe is minimum of 30" above  base is flat against roof. Replace as many  highest point of roof cutout. Termination  shingles as needed to cover ex
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        VenTing inST alla Tion Continued Terminations/Spark Arrestor The fireplace system must be terminated with  the listed round top or chase terminations. In  18"  any case, refer to the installation instructions  Min. supplied with the termination. Typ.  CAUTION: Do not seal open- ings on the rooftop flashing. Fol- low the installation instructions  provided with the termination  24" Min. being used. 24" Min. RTL-10D Stainless  Figure 19 - Multiple Chase Installation Level of  Inner Flue  Flue Gas 
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        opTional gaS ine l inST alla Tion Gas line hook up should be done by your  If you install a decorative gas appliance  supplier or a qualified service person. (vented gas log), the decorative gas appliance  Note: Before you proceed, make sure your  must comply with the Standard for Decorative  gas supply is turned off. Gas Appliance for Installation in Solid Fuel  Use only a 1/2" black iron pipe and appropri- Burning Fireplaces, ANS Z21.60 or Z21.84  ate fittings.  and shall also be installed in 
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        Brick inST alla Tion BRICK PANEL INSTALLATION BRICK INSTALLATION Each brick housing is stamped with a number  IMPORTANT: Installation of brick  (full size bricks are not stamped). These num- should be done after the fire- bers will help identify the brick when installing.  place is placed in a permanent  It is important to install these bricks exactly as  location. instructed. Press brick firmly into brick housing  until it snaps. Groove line on side of brick will  The brick housings are already
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        Brick inST alla Tion Continued HEARTH BRICK MATRIx RED IvORY QTY FULL FULL 11* F124 FULL FULL F124 (112140-01) (112140-05) ASH BRICK ASH BRICK 1 FULL FULL FULL (120848-01) (120848-03) F012R F012W 2 F126 FULL FULL F126 F124R F124W 2 120848 FULL FULL F125R F125W 2 F125 Ash Brick F125 F126R F126W 2 F128 F012 F012 F128 F128R F128W 2 36" Hearth * Includes 2 extra bricks. RED IvORY QTY FULL FULL 13* F133 F011 F133 (112140-01) (112140-05) ASH BRICK ASH BRICK 1 F123 FULL FULL F123 (120848-01) (120848-03
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        Brick inST alla Tion Continued 36" FULL STACKED BRICK MATRIx F147 F147 F148 F148 F148 F148 LEFT REFRACTORY RED IvORY QTY FULL FULL F036 F158 F158 F036 FULL FULL 7 (112140-01) (112140-05) FULL FULL FULL FULL F036R F036W 3 F143R F143W 2 F158 F158 F036 FULL FULL F036 F144R F144W 1 F147R F147W 1 FULL FULL FULL FULL F148R F148W 2 F158R F158W 3 F036 FULL F158 F158 FULL F036 F185R F185W 1 F185 or F185 or F191R F191W 1 F192 F192 F191 F191 F192R F192W 1 F150 F148 F150 REAR REFRACTORY FULL FULL RED IvORY 
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        Brick inST alla Tion Continued 42" FULL STACKED BRICK MATRIx LEFT REFRACTORY F155 F017 F156 F156 F017 F155 RED IvORY QTY F033 FULL FULL FULL FULL F033 FULL FULL 8 (112140-01) (112140-05) F032 FULL F158 F158 FULL F032 F017R F017W 1 F032R F032W 3 FULL FULL FULL FULL F033 F033 F033R F033W 3 F143R F143W 3 F032 FULL FULL F032 F158 F158 F151R F151W 1 F155R F155W 1 F033 FULL FULL FULL FULL F033 F156R F156W 1 F190 or F186 F190 or F186 F158R F158W 2 F151 F151 F032 F032 F186R F186W 1 F190R F190W 1 F157 F0
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        Brick inST alla Tion Continued 50" FULL STACKED BRICK MATRIx LEFT REFRACTORY F147 F147 RED IvORY QTY F149 F148 F148 F148 F148 F149 FULL FULL 7 FULL FULL F032 F158 F158 F032 (112140-01) (112140-05) F032R F032W 3 FULL FULL FULL FULL F033 F033 F033R F033W 3 F143R F143W 2 FULL FULL F032 F158 F158 F032 F144R F144W 1 F145R F145W 1 FULL FULL FULL FULL F033 F033 F146R F146W 1 F147R F147W 1 F032 FULL FULL F032 F158 F158 F148R F148W 2 F149R F149W 1 F145 or F145 or F146 or F146 or F033 F033 F191 F191 F192 
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                        F115 F113 F068 F113 F072 FULL FULL F072 F113 FULL FULL F189 F072 FULL FULL F072 F165 F108 F072 F072 F107 FULL F068 F107 FULL F084 FULL F107 FULL F168 F084 FULL F161 F120 F084 FULL F072 F120 F168 F068 F179 F068 F120 F068 F112 FULL F120 F110 F068 FULL F188 F110 FULL F110 F180 Brick inST alla Tion Continued 36" FULL HERRINGBONE BRICK MATRIx F074 F074 LEFT REFRACTORY RED IvORY QTY FULL FULL 6 (112140-01) (112140-05) F068R F068W 1 F071R F071W 1 F072R F072W 5 F074R F074W 2 F113R F113W 3 F115R F115W 1 
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        F064 F072 FULL F064 F068 F072 FULL F064 FULL F068 FULL F064 FULL F068 F163 FULL F068 F072 F072 F169 FULL F072 F068 FULL F072 F072 FULL F089 FULL FULL F072 FULL F063 FULL F161 FULL F168 F063 FULL F072 F071 F063 F161 FULL F071 F178 F068 F072 FULL F071 FULL F101 FULL FULL F071 FULL F100 FULL F165 FULL F100 FULL F100 F164 F174 Brick inST alla Tion Continued 42" FULL HERRINGBONE BRICK MATRIx F074 F074 LEFT REFRACTORY RED IvORY QTY F120 FULL FULL 6 (112140-01) (112140-05) F064R F064W 4 F120 F068R F068