Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        RESIDENTIAL AND OUTDOOR WOOD BURNING FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
PFS
®
C US
ICC-ES #ESR-2542
MODELS (V)S42 SERIES
SAVE THIS BOOK
This book is valuable. In addition to instructing you 
on how to install and maintain your appliance, it also 
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep 
it with your other important papers.
This fireplace is approved for use as a wood burning 
fireplace or for use with a vented 
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        TABLE OF CONTENTS Safety .................................................................. 2 Operation	and	Maintenance	Guidelines ............ 12 Specifications ...................................................... 3 Parts .................................................................. 14 Fireplace	Installation............................................ 4 T echnical	Service............................................... 17 V enting	Installation .............................................
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        SPECIFICATIONS ELECTRICAL 1" AIRSPACE TO COMBUSTIBLE OUTLET RIGHT SIDE 0" TO GAS LINE MATERIAL KNOCK OUTS TOP SPACERS NO COMBUSTIBLE MATERIAL ON FACE 8.125" 2.5" 6.75" 10.625" 12" AIR KIT  KNOCK OUT LEFT SIDE GAS LINE COMBUSTIBLE KNOCK OUTS WALL BOARD 3/4" AIR SPACE BACK AND SIDES 12.625" 8.125" 2.5" NOT LESS THAN 12" TO PERPENDICULAR SIDEWALL OUTSIDE AIR 10.625" (LEFT SIDE ONLY) 14.25" HEARTH EXTENSION 66" X 20" 12" 0" TO EACH SIDE BOTTOM 29.5" 36" 16.25" 22.5" 12.25" 39" 0.625" 48" ROUND TOP T
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        FIREPLACE INSTALLATION SELECTING LOCATION FRAMING T o 	 determine 	 the 	 safest 	 and 	 most 	 efficient 	 1.	 Frame 	 opening 	 for 	 the 	 fireplace 	 using	 location	 for	 the	 fireplace,	 you	 must	 take	 into	 dimensions	shown	in	Figures	1	and	2. consideration the following guidelines: 2.	 If	 fire pl a ce 	 i s	 to	 b e	 i n sta l l ed 	 d i re ctl y	 o n	 1.	 The	 location	 must	 allow	 for	 prope r	 clear- carpeting, tile (other than ceramic) or any  ances	(see	Figures	1	and	2). combust
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        FIREPLACE INSTALLATION DRAIN PAN (DP42)  WARNING: Hearth extension  For	 outdoor	 installations,	 the	 fireplace	 enclo- sure must allow for adequate drainage and is to be installed only as shown  fresh	 air	 ventilation.	 It	 is	 recommend ed	 that	 in Figure 3. a sealed, corrosion resistant catch pan with  provision for drainage be installed under the MANTELS fireplace	 within	 the	 fireplace	 enclosure	 (see	 A mantel may be installed if desired (see  Accessories, page 16). F igure 	 4). 	 Wo
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        VENTING INSTALLATION LINEAL GAIN PART NO. DESCRIPTION GAIN OPTIONAL OUTSIDE AIR KIT  42" Fireplace 44" (MODEL AK4/AK4F) 12-8DM 5 Pipe	Section 10 / " 8 The	 installation	 of	 an	 outside	 air	 kit	 should	 12-8HT be performed during the rough framing of  18-8DM 5 Pipe	Section 16 / " 8 the	 fireplace	 due	 to	 the	 nature	 of	 it's	 location.	 18-8HT Outside	 combustio n	 air	 is	 accessed	 through	 24-8DM 5 a 	 ven te d 	 craw l 	 spa ce 	 (AK4F) 	 or 	 th rou gh 	 a	 Pipe	Section 23 / " 8 24-8HT
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        VENTING INSTALLATION Continued Continue	 to	 assemble	 chimney	 sections	 as	 OFFSET RISE CHIMNEY LENGTH outlined, making sure that both the inner and  A B 48" 36" 24" 18" 12" 3 3 outer	 pipe	 sections	 are	 locked 	 together .	 When	 4 / 8" 16 / 8" ELBOW	SET 	ONL Y installing double wall snap-lock chimney 3 1 9 /4" 25 /2" 1 together, it is important to assure the joint be- 3 3 12 / " 30 / " 1 4 4 tween	 the	 chimney 	 sections	 is	 locked.	 Check	 3 15" 34 / " 1 4 by	 pulling 	 chimney 	 upward
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        VENTING INSTALLATION Continued See	Detail	 A Existing  2"	Min. Ceiling	 Frame Firestop	 Spacer Straps Straps Screws	or	 Detail	B Staples	 Angle	Firestop See	Detail	B (Min.	of	8) Figure 10 - Firestop Spacer with Living  Space Above Ceiling Screws	or	Staples	 Straps Firestop	 (Min.	of	8) Straps Spacer Detail	 A Existing  Return	Elbow Ceiling	 Frame Figure 8 - Ceiling Support Pipe   12S-8DM Figure 11 - Firestop Spacer with Attic  Space Above Ceiling Screws B PENETRATING ROOF T o	 maintain	 a	 1"	 c
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        VENTING INSTALLATION Continued Minimum Measurements Storm Collar Installation (SC1 or SC2) 3 14 / " 8 Place	 storm	 collar	 over	 pipe	 and	 slide	 down	 (36.5 cm) 30" 1" until it is snug against the open edge of the  (2.5 (76.2 cm) flashing	 (see	 Figure	 14).	 Use	 SC1	 for	 all	 round	 cm) 1" te rmi n atio ns 	 a nd 	 SC 2 	 fo r 	 a ll 	 te rmi n atio ns	 (2.5 cm) with slip sections. Apply waterproof caulk  1" around the perimeter of the collar to provide  (2.5 cm) a proper seal. W aterproof
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        VENTING INSTALLATION Continued T erminations	 with	 16"	 slip	 pipe	 sections	 are	 10 FOOT RULE available.	 The	 R TT -8DM	 and	 R TTL-8DM	 are	 All	 flue	 gas	 outlet	 chimney	 terminatio ns	 must	 approved 	 for 	 flashing 	 installations. 	 When	 extend a minimum of 3 feet in height above the  needed, these adjustable terminations may be  highest point where it passes through the roof  used in combination with the pipe assembly to  and must be at least 2 feet above the high- achieve the corr
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        VENTING INSTALLATION Continued EFFECTIVE HEIGHT EFFECTIVE HEIGHT  OF TERMINATION CAP OF TERMINATION CAP MIN. HEIGHT  OF 22 FT. (WITH 2 ELBOW SETS) MAX. HEIGHT OF 50 FT. MAX. HEIGHT 50 FT. (ANY SYSTEM) EFFECTIVE HEIGHT EFFECTIVE HEIGHT  OF TERMINATION CAP OF TERMINATION CAP 14.5 FT. 14.5 FT. MINIMUM MINIMUM UP TO  HEIGHT HEIGHT 6FT. MAX. UP TO  6FT. MAX. 30E-8DM 30E-8DM Figure 18 - Typical Residential Installations OPTIONAL GAS LINE INSTALLATION G as 	 line 	 hook 	 up 	 s hould 	 be 	 done 	 by 
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        OPTIONAL GAS LINE INSTALLATION Continued  CAUTION: All gas piping  WARNING: Do not oper- ate an unvented gas log set in  and connections must be tested  this fireplace with the chimney  for leaks after the installation  is completed. After ensuring removed. that the gas valve is on, apply  If	 you	 install	 a	 decorative	 gas	 appliance	 (vented	 soap and water solution to all  gas log), the decorative gas appliance must  connections and joints. Bubbles  comply with the Standard for Decorative G
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        OPERATION AND MAINTENANCE GUIDELINES GLASS DOORS Glass	 doors	 are	 optional	 with	 the	 fireplace.	 W hen 	 t he 	 fireplace 	 is 	 in 	 operat ion, 	 doors	 must be fully opened or fully closed position  Doors	Fully	Closed only 	 or 	 a 	 fire 	 hazard 	 may 	 be 	 created 	 (see	 Fireplace	Front Figure	21). A 	 fireplace	 equipp ed	 with	 glass	 doors	 oper- ates	 mush	 dif ferently	 than	 a	 fireplace	 with	 an	 open	 front.	 A 	 fireplace	 with	 glass	 doors	 has	 a	 Doors limited amount of
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        OPEN CLOSE OPERATION AND MAINTENANCE GUIDELINES Continued OUTSIDE AIR AND DAMPER  Damper	 HANDLE OPERATION Handle Keyway  The	 damper	 handl e,	 which	 opens	 and	 closes	 Slot the damper blade, is located in the upper front  face	 of	 the	 fireplace.	 Pushing	 the	 handle	 into	 the left of the keyway slot will free the damper  blade 	 to 	 automatically 	 open. 	 Pushing 	 the	 handle in to the right will lock the damper  blade	closed	(see	Figure	22). The	 outside	 air	 kit	 handle	 is	 locate
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        PARTS WOOD BURNING FIREPLACE MODELS S42, S42H, S42R, S42RH, VS42,  VS42H, VS42R AND VS42RH Right Side Rear Bottom Front Bottom Left Side REFRACTORY BRICK KEY  NO. PART NO. DESCRIPTION QTY. 9 107812-03 Left	Refractory ,	 T extured	White	Brick • 1 108169-03 Left	Refractory ,	 T extured	White	Herringbone • 1 107812-02 Left	Refractory ,	 T extured	Red	Brick • • 1 108169-02 Left	Refractory ,	 T extured	Red	Herringbone • • 1 107812-01 Left	Refractory ,	Smooth	White	Brick • 1 108169-01 Left	Refractory 
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        PARTS WOOD BURNING FIREPLACE MODELS  S42, S42H, S42R, S42RH, VS42, VS42H, VS42R AND VS42RH 35 29 2 1 21 5 8 15 17 28 20 30 25 9 18 19 11 37/38 7 12 3 36 34 31 4 24 10 32 6 26 33 22 16 13 27 14 16 23 27 16 www.fmiproducts.com 111099-01L                                                                                                                                                                                                                                                                         
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        PARTS WOOD BURNING FIREPLACE MODELS S42, S42H, S42R, S42RH, VS42,  VS42H, VS42R AND VS42RH This	list	contains	replaceable	parts	used	in	your	fireplace. KEY  NO. PART NO. DESCRIPTION QTY. 1 107797-01 Insulation	Pan 1 2 ** Fireplace	 T op 1 3 107800-01 Fireplace	Surround 1 4 106642-01 Air	Rod	Retainer 1 5 106643-01 Damper	Rod	Retainer 1 6 ** Firebox	Bottom 1 7 ** Firebox	Surround 1 8 ** Air	Separator 1 9 See	Page	15	 Left	Refractory 1 10 See	Page	15	 	 Right	Refractory 1 11 See	Page	15	 Rear	Refra
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        ACCESSORIES DOUBLE WALL PIPE 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT BI-FOLD GLASS DOOR BDO42 - Black BDO42B - Brushed Brass BDO42P - Platinum ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM 30° OFFSET AND RETURN 30E-8DM ANTI-DRAFT SHIELD (Round Top Termination Only) ADS-8DM FIRESTOP SPACER FS-8DM HOOD STAINLESS STEEL - HS42 Required	 when	 installing	 a	 vent-free	 gas	 log	 in	this	fireplace. DRAIN PAN DP42 18 www.fmiproducts.com 111099-01L
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                        ACCESSORIES Continued OUTSIDE AIR KIT FOR SIDE WALL  INSTALLATION - AK4 MESH ROUND TOP TERMINATIONS RT-8DM MESH ROUND TOP TERMINATIONS  WITH SLIP SECTION RTT-8DM OUTSIDE AIR KIT FOR FLOOR  INSTALLATION - AK4F ROUND TOP TERMINATIONS WITH  LOUVERS RTL-8DM ROUND TOP TERMINATIONS WITH  SQUARE CHASE-TOP  LOUVERS WITH SLIP SECTION TERMINATION RTTL-8DM ET-8DM, ETO-8DM ECONO-TOP TERMINATION WITH  SLIP SECTION ETL-8DM, ETLO-8DM STORM COLLAR SC1-1 For RT-8DM and RTL-8DM SC2-1 For RTT-8DM and RTTL-8DM 1110
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        2701	S.	Harbor	Blvd. Santa	 Ana,	CA 	92704 111099-01 1-866-328-4537 Rev .	L www.fmiproducts.com 03/11 20 www.fmiproducts.com 111099-01L