Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Models:
6000GBV
6000GBV-IPI
6000GBV-LP
6000GBV-IPILP
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with 
and maintenance these instructions for safe 
party responsible for use 
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these 
HOT SURFACES! 
instructions is not followed exactly, a fi re 
Glass and other surfaces are hot 
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        Read this manual before installing or operating this appliance.  Please retain this owner’s manual for future reference. This owner’s manual should be retained for future  A. Congratulations reference. We suggest that you keep it with your other  Congratulations on selecting a Heat & Glo gas fi replace, an  important documents and product manuals. elegant and clean alternative to wood burning fi replaces.  The information contained in this owner’s manual, unless  The Heat & Glo gas fi replace you h
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                            Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        13 Finishing   A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 32 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 14 Appliance Setup   A. Remove Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . 33 B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 33 C. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 D. Accessories . . . . . . . . . . . . . . . . . . . . . .
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        B. Limited Lifetime Warranty Hearth & Home Technologies LIMITED WARRANTY Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet  and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada.   Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.  Warranty Period HHT Manufactured Appliances and Venting Components Covered
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        B. Limited Lifetime Warranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass  gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials.  Rust and/or corrosion  on any of the metal surfaces, cast iron components, baffl es, fi repots, doors, or fi rebox area are not covered by this  warranty. • Noise resulting from minor expansion, contraction, or movement of certain p
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        Listing and Code Approvals   1 1  A. Appliance Certifi cation C. BTU Specifi cations Orifi ce  Maximum Minimum Models Size   MODELS:  6000GBV, 6000GBV-IPI,  Input BTUH Input BTUH U.S. (0-2000 ft.) or Canada (2000-4500 ft.) (DMS)      6000GBV-LP, 6000GBV-IPILP US 27,000 18,000 #40  6000GBV LABORATORY: Underwriters Laboratories, Inc. (UL)  6000GBV-IPI CAN 24,300 16,200 #41 TYPE: B-Vent Gas Appliance STANDARD: ANSI Z21.50-2002•CGA2.2 US 27,000 18,000 #53  6000GBV-LP  6000GBV-IPILP CAN 24,300 16,200 #5
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        User Guide Operating Instructions   2 2   • Keep remote controls out of reach of children. A. Gas Fireplace Safety • Never leave children alone near a hot fi replace, whether  operating or cooling down. WARNING • Teach children to NEVER touch the fi replace. HOT SURFACES!  Glass and other surfaces are hot during  • Consider not using the fi replace when children will be  operation AND cool down. present. Hot glass will cause burns. Contact your dealer for more information, or visit: www. • DO NOT t
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        CLEAR SPACE  3 FT. IN FRONT OF FIREPLACE For safety: C. Fan Kit (optional) • Install a switch lock or a wall/remote control with child  If desired, a fan kit may be added.  Contact your dealer to  protection lockout feature. order the correct fan kit. • Keep remote controls out of reach of children. D. Clear Space See your dealer if you have questions. WARNING! DO NOT place combustible objects in front  of the fi replace or block louvers. High temperatures may  H. Outside Air (optional) start a fi
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        J. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries.  When using batteries, unplug the transformer. To prolong battery  life, remove them when using the transformer. FOR YOUR SAFETY LIGHTING READ BEFORE LIGHTING INSTRUCTIONS (IPI) WARNING: If you do not follow these instructions exactly, a fi re or explosion  may result causing property damage, personal injury or loss of life. 1. Turn off all electric power to the appliance. •  Immediately call your gas supplie
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        K. Lighting Instructions (Standing Pilot) LIGHTING FOR YOUR SAFETY INSTRUCTIONS READ BEFORE LIGHTING 1. Open control access panel. WARNING: If you do not follow these instructions exactly, a fi re or explosion  2. Turn off all electric power to  may result causing property damage, personal injury or loss of life. the appliance. 3. Push in gas control knob  A. This appliance has a pilot which •   If you cannot reach your gas sup- slightly and turn clockwise  plier, call the fi re department. must b
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        L. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours  continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly. See Section 14.G. • Clean fi xed glass assembly. See Section 3. • Replace the fi xed glass assembly and run continuously  on high an additional 12 hours. This cures the materials used to manufacture the fi re- place. NOTICE! Open windows for air circulation during fi re- place break-in. •
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        Maintenance and Service   3 3   Doors, Surrounds, Fronts Any safety screen or guard removed for servicing must be  replaced prior to operating the fi replace. Frequency: Annually By:  Homeowner When properly maintained, your fi replace will give you  many years of trouble-free service.  We recommend an- Tools needed:  Protective gloves, stable work surface nual service by a qualifi ed service technician.   • Assess condition of screen and replace as necessary.   A. Maintenance Tasks-Homeowner • Ins
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        Frequency: Annually Venting By:  Qualifi ed Service Technician Frequency: Seasonally Tools needed: Protective gloves, vacuum cleaner, dust  By:  Homeowner cloths Tools needed:  Protective gloves and safety glasses. • Vacuum and wipe out dust, cobwebs, debris or pet hair.   • Inspect venting and termination cap for blockage or  Use caution when cleaning these areas.  Screw tips that  obstruction such plants, bird nests, leaves, snow, debris,  have penetrated the sheet metal are sharp and should  e
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        Figure 3.1  IPI Pilot Flame Patterns Figure 3.2  Standing Pilot Flame Patterns Heat & Glo  •  6000GBV, 6000GBV-IPI  •  2104-900  Rev. H  •  11/08 15                                                                                                                                                                                                                                                                                                                                                                
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        Installer Guide Getting Started   4 4  A. Typical Appliance System NOTICE:  Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not  drawn to scale. Actual product may vary from pictures in manual VERTICAL TERMINATION CAP  (SECTION 6) NON-COMBUSTIBLE ROOF FLASHING  MAINTAINS MINIMUM CLEARANCE  AROUND PIPE (SECTION 4.D) STORM COLLAR (SECTION 4.D) VENT PIPE PENETRATES ROOF PREFERABLY WITHOUT AFFECTING ROOF RAFTERS (SECTION 8.B) VENT P
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        • The vent system components and decorative doors and  B. Design and Installation Considerations fronts may be shipped in separate packages.  Heat & Glo B-type vent gas appliances are designed to  • If packaged separately, the log set and appliance grate  operate with all exhaust gases expelled to the outside of  must be installed.  the building, and combustion air pulled from the room. • Report to your dealer any parts damaged in shipment,  Installation MUST comply with local, regional, state a
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        • Ensure adequate outdoor air is supplied for combustion  E. Negative Pressure appliances and exhaust equipment. WARNING! Asphyxiation Risk! Negative pressure can  • Ensure furnace and air conditioning return vents are not  cause spillage of combustion fumes and soot. Fireplace  located in the immediate vicinity of the fi replace. needs to draft properly for safety. • Avoid installing the fi replace near doors, walkways or  Draft is the pressure difference needed to vent fi replaces  small isolated
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                        Framing and Clearances   5 5   NOTICE: Illustrations refl ect typical installations and are  A. Selecting Appliance Location FOR DESIGN PURPOSES ONLY. Illustrations/diagrams  When selecting a location for the appliance it is important to  are not drawn to scale. Actual installation may vary due to  consider the required clearances to walls (see Figure 5.1). individual design preference. WARNING! Risk of Fire or Burns! Provide adequate  clearance around air openings and for service access.  Due to
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        To further prevent drafts, the wall shield and ceiling fi re- B. Constructing the Appliance Chase stops should be caulked with high temperature caulk to  A chase is a vertical box-like structure built to enclose the  seal gaps. Gas line holes and other openings should be  gas appliance and/or its vent system. In cooler climates  caulked with high temp caulk or stuffed with unfaced in- the vent should enclosed inside the chase. sulation. If the appliance is being installed on a cement  NOTICE: Tre