Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Models:
6100PLUS
Fresh Air Fireplace
Refractory must be ordered separately.
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow • Leave this manual with 
• Important operating and 
these instructions for safe party responsible for 
maintenance instructions 
installation and operation. use and operation.
included.
WARNING WARNING
HOT! DO NOT TOUCH. 
If the information in these instruc-
SEVERE BURNS MAY RESULT.
tions is not foll
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Heat & Glo gas appliance—an The information contained in this owner’s manual, unless  elegant and clean alternative to wood burning appliances. The noted otherwise, applies to all models and gas control  Heat & Glo gas appliance you have selected is designed to systems. provide the utmost in safety, reliability, and effi ciency. You
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        Table of Contents 1 Listing and Code Approvals  4 9 Finishing  20 A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . 4 A. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 B. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 C. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . 4 10 Appliance Setup  21 E. Non-Combustible
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        Listing and Code Approvals  1   A. Appliance Certifi cation B. BTU Specifi cations Max Input Min Input MODELS:   6100PLUS Model BTUH BTUH Orifi ce Size LABORATORY:   Underwriters Laboratories, Inc. (UL) 6100PLUS-LP 47,000 34,000 .082 in./2.08 mm TYPE:    Vented Gas Appliance  6100PLUS-NG 47,000 34,000 .136 in./3.45 mm STANDARD: ANSI Z21.50-2000 • ANSI Z21.47-1998 •  CSA 2.22-2000 • CGA 2.3-M98 C. High Altitude Installations The 6100PLUS is power vented. High altitude gas appliance  considerations a
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        Getting Started  2 2   A. Design and Installation Considerations CAUTION Heat & Glo vented gas appliances are designed to operate  with all exhaust gases expelled to the outside of the build- Sharp Edges ing. • Wear protective gloves and safety  glasses during installation. CAUTION C. Inspect the Appliance and Components Check building codes prior to installation. • Installation MUST comply with local, regional,  state and national codes and regulations. • Consult insurance carrier, local buildi
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        Framing and Clearances  3 3   Note:  WARNING • Illustrations refl ect typical installations and are FOR  DESIGN PURPOSES ONLY. Fire Risk • Illustrations/diagrams are not drawn to scale. Provide adequate clearance: • Actual installation may vary due to individual design • Around air openings. preference. • For service access. Locate appliance away from traffi c areas. A. Select Appliance Location Note: For actual appliance dimensions refer to  When selecting a location for your appliance it is impo
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        B. Construct the Appliance Chase WARNING A chase is a vertical boxlike structure built to enclose the gas  appliance and/or its vent system. Vertical vents that run on  Fire Risk the outside of a building may be, but are not required to be,  installed inside a chase. • Construct chase to all clearance  specifi cations in manual. Construction of the chase may vary with the type of build- • Locate and install appliance to all  ing. These instructions are not substitutes for the require- clearance s
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        C. Clearances 32-7/8 in. (835 mm) 38-3/4 in. (984 mm) 0 in. 23-1/2 in. to floor (597 mm) 1/2 in. (13 mm) 42 in. 0 in. to combustibles (1067 mm) in front of the FAF 0 in. Figure 3.2 Clearances to Combustibles  D. Mantel Projections Top of Appliance Drywall 32-7/8 in. minimum to ceiling A 48 in. (1219 mm) max. B 12 11 Mantel Leg or  10 19-3/4 Perpendicular Wall 9 19-3/4 8 19-3/4 7 16-3/4 6 16-3/4 A 1 in. (25 mm) min. 5 16-3/4 4 to perpendicular wall 13-3/4 3 13-3/4 B 3-1/2 in. (89 mm) min. 13-3/4
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        Termination Locations  4 4  A. Vent Termination Minimum Clearances WARNING Fire Risk Explosion Risk Maintain vent clearance to combustibles as  specifi ed. • Do not pack air space with insulation or  other materials. Failure to keep insulation or other materials  away from vent pipe may cause fi re. Note: Refer to the HRV200PLUS installation manual for  additional installation and venting instructions.  Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05 9                               
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        Vent Information and Diagrams  5 5  Note: Refer to the HRV200PLUS installation manual for  additional installation and venting instructions. WARNING Fire Risk Fumes Risk This unit MUST be vented with the  HRV200PLUS. • Do not connect to a chimney fl ue. The 6100PLUS will not vent correctly unless  it is connected to the HRV200PLUS. 10 Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05                                                                                                      
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        Appliance Preparation  6   A. Securing and Leveling the Appliance  WARNING Fire Risk! • Prevent contact with sagging, loose  insulation. • Do NOT install against combustible  materials such as exposed insulation,  plastic and insulation backer. The diagram shows how to properly position, level, and se- cure the appliance. Nailing tabs are provided to secure the  appliance to the framing members. • Place the appliance into position.  • Level the appliance from side to side and front to back. Fig
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        Gas Information  7  A. Fuel Conversion C. Gas Connection Before making gas connections ensure appliance being in- Note: Have the gas supply line installed in accordance  stalled is compatible with the available gas type. with local building codes, if any. If not, follow ANSI  Any natural or propane gas conversions necessary to meet 223.1. Installation should be done by a qualifi ed installer  the appliance and locality needs must be made by a quali- approved and/or licensed as required by the loc
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        WARNING Fire Risk Explosion Risk • Gas build-up during line purge may  ignite. • Purge should be performed by qualifi ed  technician. • Ensure adequate ventilation. • Ensure there are no ignition sources such  as sparks or open fl ames. • A small amount of air will be in the gas supply lines. When  fi rst lighting appliance it will take a short time for air to  purge from lines. When purging is complete the appliance  will light and operate normally. WARNING CHECK FOR GAS LEAKS Fire Risk Explosion 
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        Electrical Information  8   A. Recommendation for Wire WARNING • Requires 110 VAC to be wired to the junction box for proper  operation of the appliance. Shock Risk Explosion Risk B. Connecting to the Appliance Do NOT wire 110V to valve. • Low voltage and 110 VAC voltage cannot be shared within  Do NOT wire 110V to wall switch the same wall box. • Incorrect wiring will damage millivolt  values. • Incorrect wiring will override IPI safety  CAUTION lockout and may cause explosion. Battery polarity
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        C. System Wiring 6100PLUS Requirements  • This gas appliance requires a 110VAC supply to the gas appliance junction box for operation. A wiring diagram is shown  in Figure 8.1. • The 6100PLUS is equipped with an intermittent pilot control valve which operates on a 3 volt system. See ignition wiring  diagram, Figure 8.1. • The 6100PLUS is supplied with a 3 volt  AC transformer, which requires the installation of the supplied junction box. It is  highly recommended that the junction box be install
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        HRV200PLUS Control Wiring  The 6100PLUS is designed to operate as a system with  The connections are illustrated in Figure 8.2. A short  the HRV200PLUS. Six low-voltage wires are required jumper wire is required to be fi eld installed between R2  to electrically connect the two appliances. Common 24 and 12V on the HRV200PLUS control board. gauge solid conductor thermostat wire, or equivalent may  be used. OFF/ON EMBER LIGHTS HI/EMBER FIRE T14 T13 T12 T11 T10 T9 P1 K3 REM REM T8 T7 Not Used LOW LI
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        Figure 8.3 Appliance Circuit Board Wiring  Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05 17                                                                                                                                                                                                                                                                                                                                                                                                        
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        D. Wall Switch This appliance comes with a triple-gang wall switch which controls the following functions: • Flame - On/Off  Turns the appliance burner operation on and off. This switch may be overridden by the use of a wall switch, remote control  or hearth thermostat connected to the REM terminals. • Electric Embers - On/Off  Turns electric ember lights on and off. Electric ember lights are optional only when the appliance burners are not in use.  Electric ember lights are always on during fl a
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                         F. Junction Box Installation If the box is being wired from the OUTSIDE of the appliance: • Remove the cover plate located on the outer shell - right side (see Figure 8.5). • Install the supplied Romex™ connector in the cover plate. • Feed the necessary length of wire through the connector. • Make all necessary wire connections and reattach the cover plate to the outer shell. If the box is being wired from the INSIDE of the appliance: • Remove the screw attaching the junction box/receptacle to
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        Finishing  9  A. Mantel Projections Figure 9.1 shows the minimum vertical and corresponding  maximum horizontal dimensions of appliance mantels or  Top of other combustible projections above the top front edge of  Appliance Drywall the appliance. A 48 in. 32-7/8 in. minimum (1219 mm) to ceiling max. B Mantel Leg or  Perpendicular Wall 12 11 10 19-3/4 9 19-3/4 A 1 in. (25 mm) min. 8 19-3/4 7 16-3/4 to perpendicular wall 6 16-3/4 5 16-3/4 B 3-1/2 in. (89 mm) min. 4 13-3/4 3 from fireplace opening