Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        ENGLISH ESPAÑOL
See page 1 Vea la página 15
®
The Care Free 
Warm Mist Humidifier
Models 35201, 35202, 35203, 35253, 
36200, 36201, 36203, 36204, 36253
www.hunterfan.com
41793 10/19/2006                                 © 2006 Hunter Fan Company                                                                                                                                                                                                                                                                
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        Read and Save TheSe InSTRucTIonS ®   Thank you for purchasing the Care Free 8. This unit was designed to be used with  Warm Mist Humidifier by Hunter Fan distilled and/or tap water. do no T add  Company. Please read and save these scented oils, perfumes or fragrance  instructions to receive maximum benefit additives to the water.  and performance from your humidifier. 9. do no T attempt to move or  disassemble the Base while there is hot  water still in the unit. Allow a minimum   Important Safe
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        ENGLISH ® how The care Free Warm Mist humidifier Works ® water, humidified air or users. Conduct  The Care Free Warm Mist Humidifier has routine cleaning and maintenance based  a unique, patented design with several upon use and individual conditions.  innovative features: • no White dust – The Care Free® Warm  • Removable Boiling chamber – Mist Humidifier produces no white   The detachable heater can be easily  dust that can settle on furniture or be  removed for cleaning and maintenance.  inha
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        1. Remove the Care Free® Warm Mist 6. Place the Water Tank back onto the Base.  Humidifier from its packaging. Make sure the Water Tank is properly  seated on the Base or the humidifier will  2. Select a location for your humidifier. The not work properly. location should be flat, hard, water- resistant, and at least six (6) inches  away from walls and sources of heat.  Water  Mount the humidifier on a drip tray  if you are using the unit on a wood  Tank surface or other surface which could be  
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        ENGLISH operating Your humidifier There are two humidity level controls:  Push the Power Button on the base of the  unit AGAIN to turn the humidifier OFF. No  1. adjustable humidistat* – Allows you to indicator light will be illuminated, which  adjust the humidity setting. indicates the unit has been turned OFF.   3.  niteGlo™ night Light Button* –  Illuminates with a soft blue glow.  Turn the dial to the right to increase  humidity.   Turn the dial to the left to decrease  humidity. Push the Ni
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        Refilling The Water Tank 1.  When the water level is low, push the 5. Replace the Tank Cap by screwing it  POWER button to turn the humidifier OFF clockwise onto the Water Tank. Make  and unplug the humidifier. sure that the tank cap is properly seated  before screwing it back onto the tank to  no Te: When the tank level is too low, the ensure a proper seal.  humidifier will turn OFF and display a red light. 6. Place the Water Tank back onto the Base.  Make sure the Water Tank is properly  seate
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        ENGLISH Reassembly of humidifier Parts Exhaust Grille Medicine Cup Water Tank Boiler  Cover Tank Cap Base Boiling  Chamber Adjustable Humidistat* Night Light Button* Power Button *Not available on all models cleaning The humidifier and The Water Tank Many regions have hard water with high sink or a tub. Unscrew the Tank Cap by  concentrations of minerals. When water twisting it counterclockwise and empty  ® evaporates from the Care Free Warm any water in the Water Tank. Mist Humidifier, minerals
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        Boiler  Cover Base Boiler Boiling  Chamber 4. Place the Boiling Chamber into an empty humidifier surface, to clean plastic parts.  sink and carefully lift the Boiling Chamber neveR use gasoline, kerosene, glass  Cover by pressing the Chamber Cover cleaner, furniture polish, paint thinner,  Release Tab. This will expose the Heater. or other household solvents to clean any  Drain all water and rinse with cool, clean part of the humidifier.  water. Use a soft brush or sponge to clean  the Boiling C
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        ENGLISH Storage Tips If you do not plan to use your humidifier the tank and the hot and cold water  for an extended period of time, such reservoirs.  as during the summer months, it is 3. Make sure the unit is completely dry.  important that you follow these instructions 4. Leave the Tank Cap off to expose the  to help prevent problems from developing Water Tank to air.  in the unit. 5. Pack the humidifier in the original  carton and store it in a cool, dry  1. Clean your humidifier as outlined 
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        Service Parts To obtain a service part for your humidifier, call Hunter Customer Service at 1-888- 830-1326 or e-mail us at Techsupport@hunterfan.com. Please be prepared to tell the operator the model number of your humidifier, the name of the part you need to replace, and the part number. Model Boiler Cover Exhaust Grille Medicine Cup Tank Cap Water Tank Number 35201, 35202, 36200, 96362-01-325 86731-01-325 75690-01-325 83736-01-325 96361-01-326 36201,  36204 35203, 96362-01-325 86731-01-325 75
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        ENGLISH humidifier while in your possession, or unreasonable use, including failure to provide  reasonable and necessary maintenance. This warranty does not cover humidifiers  used in commercial applications. There are no express or implied warranties as to  commercial purchasers or users.  Technical Support If you have any additional questions or problems with your Hunter Air Purifier, please call  1-888-830-1326 from 8:00 am to 5:00 pm Central Time or contact us over the Internet at www. hunte
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        41793 10/19/2006                                 © 2006 Hunter Fan Company 14                                                                                                                                                                                                                                                                                                                                                                                                                                       
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        ENGLISH ESPAÑOL See page 1 Vea la página 15 Humidificador De Niebla  ® Caliente Care Free  Modelos 35201, 35202, 35203, 35253,  36200, 36201, 36203, 36204, 36253 www.hunterfan.com 41793 10/19/2006                                 © 2006 Hunter Fan Company                                                                                                                                                                                                                                                      
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        Lea Y GuaRde eST aS InSTRuccIoneS  Gracias por comprar el Humidificador moverla.  ®  de niebla caliente Care Free de 7. Además del mantenimiento de rutina  Hunter Fan Company. Lea y guarde que puede requerir, este humidificador  estas instrucciones para obtener el requiere limpieza por temporada.  máximo beneficio y rendimiento de su Consulte y siga las instrucciones del  humidificador. apartado LIMPIEZA DEL HUMIDIFICADOR  Y DEL TANQUE DE AGUA.  8. Esta unidad fue diseñada para utilizar   Instru
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        1. Retire el Humidificador de niebla caliente 6. Coloque el tanque de agua nuevamente  Care Free® de su paquete. en la base. Asegúrese que el tanque de  agua esté adecuadamente asentado en  2. Seleccione una ubicación para su la base o el humidificador no funcionará  humidificador. El lugar debe ser plano, correctamente. duro, resistente al agua y al menos a 15  cm (6") de distancia de las paredes y las  fuentes de calor. Monte el humidificador  Tanque  en una bandeja de goteo si está usando  De
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                        ESPAÑOL operación de Su humidificador Hay dos controles de nivel de humedad:  Presione el botón de encendido en  la base de la unidad OTRA VEZ para  1. humidistato ajustable* – Le permite cambiar el ajuste a LOW (BAJO). Una  modificar el ajuste de humedad. luz indicadora amarilla se iluminará  indicando un ajuste LOW (BAJO).   Presione el botón de encendido en la  base de la unidad OTRA VEZ para apagar  el humidificador. Ninguna luz indicadora  estará iluminada, lo que indica que la  unidad ha s
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        Rellenado del Tanque de agua 1. Si el nivel de agua es bajo, presione  el botón ENCENDIDO para apagar el  humidificador y desconéctelo.  no Ta: Si el nivel del tanque es muy bajo, el humidificador se apagará (OFF) y se encederá una luz roja.  6. Coloque el tanque de agua nuevamente  en la base. Asegúrese que el tanque de  agua esté adecuadamente asentado en  la base o el humidificador no funcionará  correctamente. Tanque  Luz de bajo nivel  De  de agua (roja) Agua 2. Levante el tanque de agua y