Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        1
W415-0638 / 04.24.08
$10.00 W415-0638 / 04.24.08                                                                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        2 TABLE of CONTENTS PG 2-4  INTRODUCTION 7  FINISHING     Warranty    Log Placement     General Information  8  OPERATION 5  SPECIFICATIONS     Operating Instructions     Dimensions     Maintenance     Input  9  MAINTENANCE     Gas Inlet Pressures     High Elevation Installation     Minimum Clearance to Combustibles  10-11 REPLACEMENTS  6-7    INSTALLATION     Natural Gas    Ordering Replacement Parts     Propane    Replacement Parts     Enclosures for LP Gas Supply Systems     Tank Retaining Br
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        3 NAPOLEON® gas appliances are manufactured under the strict Standard of the world recognized  ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained  craftsmen who take great pride in their work. Th e burner and valve assembly are leak and test-fi red at a  quality test station. Once assembled the complete appliance is thoroughly inspected by a qualifi ed technician  before packaging to ensure that you, the custo
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        4 GENERAL INFORMATION • Installation and repair should be done by a  THIS GAS FIREPLACE SHOULD BE INSTALLED AND  qualifi ed service person. The appliance should be  SERVICED BY A QUALIFIED INSTALLER  to conform  inspected before use and at least annually by a  with local codes.  qualifi ed service person. More frequent cleaning  Installation practices vary from region to region and it is  may be required as necessary. It is imperative the  important to know the specifi cs that apply to your area,  
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        5 SPECIFICATIONS DIMENSIONS INPUT  Model Fuel Max. Input    Btu/Hr  GPFN Natural Gas 60,000  GPFP Propane Gas 60,000 GAS INLET PRESSURES   Natural LP (Propane) Minimum Inlet Pressure 4.5" w.c. 11.0" w.c. Maximum Inlet Pressure 14.0"w.c 14.0"w.c.  MINIMUM CLEARANCE TO COMBUSTIBLES   Inches mm Floor  *0 *0 Side Walls 24 610 Top of unit to ceiling 72 1.830 * WHEN THE PATIO FLAME IS BEING USED WITH THE OP- TIONAL TRIPOD, IT MUST NOT BE SITUATED ON A COMBUS- TIBLE SURFACE. W415-0638 / 04.24.08       
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        6 INSTALLATION The log set and the burner assembly are shipped together. ENCLOSURES FOR LP GAS SUPPLY  Remove the gas log set and burner assembly and check for  SYSTEMS damage. DO NOT install damaged components. The logs are  If you build an enclosure for an LP gas cylinder, follow these  fragile use care when handling. recommended specifi cations. You must also follow local  Place the Patiofl ame on a level/secure surface in desired  codes. location. This location must be adjacent to the gas supp
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        U R H 7 TANK RETAINING BRACKET #2 1.  Fasten the bracket to the bottom of the propane bottle  using bolt and nut supplied. (Fig. 1) 2.  Tighten the lag screw into the mounting surface leaving  1 approximately / ” of thread above the surface.   4 3.  Slide propane bottle into position so that the bracket  slides under the head of the lag screw. (Fig. 2) 4.  Tighten the lag screw onto the bracket. 5.  For fastening to a concrete surface a concrete anchor will  3. Place pocket on log #2 onto the lo
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        8 OPERATION Upon completing the gas line connection, a small amount of Once the purging is complete, the burner will light and operate  air will be in the lines. When fi rst lighting the burner, it will take as indicated in the instruction manual. Subsequent lighting  a few seconds for the lines to purge themselves of this air. of the appliance will not require such purging unless the gas  supply has been disconnected. WARNING: Read and follow the safety and lighting instructions page in this man
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        9 MAINTENANCE 1. The appliance should be inspected before initial use and  During the winter months in cold weather climates, it is  inspected and cleaned at least annually by a qualifi ed fi eld  recommended to disconnect the Patiofl ame and store it in a  service person. cool dry place. Do not store the propane tank inside. For the  2. Tampering is DANGEROUS and voids all warranties. Any remainder of the year, protect and cover your Patiofl ame from  component that is found to be faulty, must be r
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        10 1.   REPLACEMENTS Contact your Napoleon® dealer or the factory for questions MODEL & SERIAL NUMBER OF APPLIANCE concerning prices and policies on replacement parts. Normally  2.  INSTALLATION DATE OF APPLIANCE  all parts can be ordered through your Napoleon® dealer or  ART NUMBER  3.  P distributor.  4.  DESCRIPTION OF PART  When ordering replacement parts always give the following  5.  FINISH information: * IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR  FOR WARRANTY REPLACEMENT PARTS, A PH
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        11 W415-0638 / 04.24.08                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        12 W415-0638 / 04.24.08 Wolf Steel Appliance Service History This appliance must be serviced annually depending on usage. Service Technician Date Dealer Name Service Performed Special Concerns  Name