                        642  75872 Owners Manual E.B.C. Airpot /Thermal   WARRANTY STATEMENT  All electrical equipment manufactured by BLOOMFIELD    It also does not apply if the serial nameplate has been        INDUSTRIES is warranted against defects in materials and removed or unauthorized service personnel perform service.   workmanship for a period of one year from the date of original The prices charged by Bloomfield Industries for its products  installation or eighteen (18) months from the date of shipment are ba
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        TABLE OF CONTENTS  WARRANTY STATEMENT                                 xi Thank You for purchasing this  Bloomfield Industries appliance.  SPECIFICATIONS                                               1    FEATURES & OPERATING CONTROLS           2  Proper installation, professional  PRECAUTIONS & GENERAL INFORMATION   3  operation and consistent  AGENCY LISTING INFORMATION                     3  maintenance of this appliance will  ensure that it gives you the very  INSTALLATION INSTRUCTIONS       
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        642  75872 Owners Manual E.B.C. Airpot /Thermal   FEATURES AND OPERATING CONTROLS  Fig. 1  Features & Operating Controls  2                                                                                                                                                                                                                                                                                                                                                                                         
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        PRECAUTIONS AND GENERAL INFORMATION  WARNING:  ELECTRIC SHOCK HAZARD  All servicing requiring access to non-insulated components must be performed by qualified  service personnel.  Do not open any access panels which require the use of tools.  Failure to  heed this warning can result in electrical shock.    WARNING:  INJURY HAZARD  All installation procedures must be performed by qualified personnel with full knowledge of all  applicable electrical and plumbing codes.  Failure could result in pr
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        642  75872 Owners Manual E.B.C. Airpot /Thermal   INSTALLATION INSTRUCTIONS  READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION  IMPORTANT:  Unpack the unit.  Inspect all components for completeness and  To enable the installer to make  condition.  Ensure that all packing materials have been removed  a quality installation and to   from the unit.     minimize installation time, the  Verify that the Spray Head Gasket and Spray Disk are properly  following suggestions and tests  installed.    sh
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        INSTALLATION INSTRUCTIONS (continued)  NSF requires that the brewer be able to be moved for cleaning  NOTE:  This equipment must be  underneath.  A flex line or loops of copper tubing will satisfy this  installed to comply with           requirement. See Figure 2 below.  applicable federal, state and     local plumbing codes and         ordinances.          WARNING: ELECTRIC    SHOCK HAZARD      Brewer must be properly    grounded to prevent possible    shock hazard.  DO NOT           assume a p
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        642  75872 Owners Manual E.B.C. Airpot /Thermal   OPERATION  Fig. 4  Brewer Operation Diagram  IMPORTANT: A. START-UP    Tank must be full of water         For initial start-up, or if the brewer has not been used for an          before connecting brewer         extended period of time:   to electrical power.       Heating elements will be         ♦  Be sure spray disk and brew gasket are properly installed in the    damaged if allowed to              brew head.    operate without being fully    
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        OPERATION (continued)  WATER HEATER    Water temperature is sensed by an electronic water  temperature probe inserted into the water tank.   This temperature signal is fed to the controller.    The setpoint temperature is adjustable.  The        controller sends a command signal to the power  board based upon a comparison between the      setpoint temperature and actual temperature.      See page 15.    The power board energizes the heating    elements  based on the command signal from the contr
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        642  75872 Owners Manual E.B.C. Airpot /Thermal   OPERATION (continued)  IMPORTANT:  ELECTRONIC FEATURES  DO NOT energize this    brewer until the water tank  Energizing the Brewer    has been filled.  Dry firing  When electric power is applied to the unit, all the lights will flash four  will damage heating       times and four beeps will sound.  The unit will be OFF.  elements.  See page 6.      Press the ON/OFF key.  Four beeps will sound and all lights will flash    once.  The POWER indicato
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        OPERATION (continued)  Quality Timer Quality Timer is normally   set for 30 minutes.  It can  Coffee looses its freshness as it sits on a warmer.  The Quality Timer be set for 20 minutes by  flashes the warmer lights 30 minutes after the last brew to remind you moving a jumper on the  controller.  See page 19.  that the coffee is nearing the end of its useful life.       After Hours™ Operation     During normal operation, the controller will maintain the precise           After Hours™ is an ener
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        642  75872 Owners Manual E.B.C. Airpot /Thermal   BREWING COFFEE  CAUTION:   B. PREPARATION    Burn Hazard         Place one (1) genuine Bloomfield  PAPER   FILTER       paper filter in the brew chamber.  Exposed surfaces of the        Add a pre-measured amount of  brewer, brew chamber and        fresh coffee grounds.  airpot or server may be  BREW       Gently shake the brew chamber to  CHAMBER HOT to the touch, and can        level the bed of grounds.  Slide the   cause  serious burns.        
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        CLEANING INSTRUCTIONS  CAUTION:  PROCEDURE:  Clean Coffee Brewer  Burn Hazard      PRECAUTIONS:   Disconnect brewer from electric power.                                 Allow brewer to cool.  Brewing and serving    temperatures of coffee are      FREQUENCY:       Daily  extremely hot.    Hot coffee will cause  TOOLS:                 Mild Detergent, Clean Soft Cloth or Sponge  serious skin burns.                                Bristle Brush.          CAUTION:  1.   Disconnect brewer from electric
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        642  75872 Owners Manual E.B.C. Airpot /Thermal   TROUBLESHOOTING SUGGESTIONS  SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY      Water won’t heat Brewer unplugged or circuit Check power supply cord   breaker tripped Check / reset circuit breaker       Temperature adjusted too low Turn on and set for desired     or set to OFF temperature.  See page 15       Hi-Limit thermostat tripped Allow to cool (1012, 1040 or    1072), or allow to cool and    reset hi-limit (1086, 1088)       Damaged internal comp
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        ERROR DETECTION  This brewer is designed to perform a continuous internal              CAUTION  diagnosis, and to signal faults by flashing all the lights.  In fault  ELECTRIC SHOCK  mode, warmers, heating element and water fill solenoid are turned  HAZARD  “off”, and most keypad functions are disabled.      Live electrical circuits may       Error detection (all lights flashing) will occur under two conditions:  be exposed while  performing  • Anytime a temperature in excess of 214ºF is detecte
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        642  75872 Owners Manual E.B.C. Airpot /Thermal   SERVICING INSTRUCTIONS  CAUTION ACCESS PANELS  Electric Shock   Hazard TOP PANEL:      Remove top panel to access hot water tank, thermo probe,    Opening access panels or      heating elements, brew circuit tubing, faucet valve and piping.  removing warmer plates on this    brew may expose uninsulated Top panel is held by two screws at the rear and a retaining lip at  electrical components.  the front.  Disconnect brewer from         electrical 
                    
                    Inhaltszusammenfassung zur Seite Nr. 17 
                    
                        SERVICING INSTRUCTIONS (continued)  TEMPERATURE ADJUSTMENT  CAUTION    Electric Shock  Unplug power cord or turn circuit breaker OFF.  Remove top  Hazard  panel.  Remove button plug from front panel.      These procedures involve        exposed electrical circuits.  These procedures are to be   performed by qualified          technical personnel only.                    Fig. 13   Checking and Adjusting Brew Temperature         Pull vent tube out of tank lid and insert a thermometer of known    a
                    
                    Inhaltszusammenfassung zur Seite Nr. 18 
                    
                        642  75872 Owners Manual E.B.C. Airpot /Thermal   SERVICING INSTRUCTIONS (continued)  IMPORTANT:  Water pressure  BREW TIME ADJUSTMENT     must be between 20 p.s.i and  The amount of water dispensed automatically during a brew cycle  90 p.s.i. flowing pressure.          is controlled by the SOLENOID TIME dial of the controller.    If water pressure exceeds this    value, or if water pressure      Place empty decanter under brew chamber.  Press BREW       varies greatly, a pressure    button.  Br
                    
                    Inhaltszusammenfassung zur Seite Nr. 19 
                    
                        SERVICING INSTRUCTIONS (continued)  REPLACE SOLENOID       Unplug power cord.  Turn OFF and disconnect water supply from    brewer inlet fitting.      Remove front panel.  Remove two screws holding access door in  place. Remove access door and solenoid.  Unscrew inlet fitting  cap to release solenoid from door.    Remove wiring from solenoid.    Large end of wrench 86660 can be used to hold solenoid inlet  fitting while disconnecting supply line.  Fig. 15  Fill Solenoid     REPLACE FAUCET SUPPLY
                    
                    Inhaltszusammenfassung zur Seite Nr. 20 
                    
                        642  75872 Owners Manual E.B.C. Airpot /Thermal   SERVICING INSTRUCTIONS (continued)  REPLACE HOT WATER FAUCET COIL  IMPORTANT:  When replacing    water faucet coil, also replace  (Symptom:  Brewer drips continuously from brew head, except  seal gaskets.  when faucet valve is turned OFF.)       Remove tank lid assembly per above.      Remove two hex nuts hot water coil to cover.  Pull coil from    mounting holes.      Reassemble in reverse order.     NOTE:  Any abrasion or     REPAIR HOT WATER F