Resumen del contenido incluido en la página 1 
                    
                        0311   A  OI
	
GT SYSTEM
Apartment Intercom System
Installation manual                                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Resumen del contenido incluido en la página 2 
                    
                        PRECAUTIONS  Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions  General Prohibitions General Precautions WARNING 1. All units, except for the entrance station, are designed for indoor use only. Do not use  (Negligence could result in death or serious injury.) outdoors.  1. The units must be installed and wired by a qualified technician. Having installation  2. The unit turns inoperative during power failure. performed by an unqualified technician cou
                    
                    Resumen del contenido incluido en la página 3 
                    
                                                                                                                                                                                                                                                                                                                                                - 3 -                                                                                                                                                                                       
                    
                    Resumen del contenido incluido en la página 4 
                    
                        W P W P W P D A M J G T D A M J G T D A M J G T X Q X Q X Q 1 2 3 B E 4 5 6 H K N 7 8 9 U 0 1 2 3 B E 4 5 6 H K N 7 8 9 U 0 1 2 3 B E 4 5 6 H K N 7 8 U 9 0 SYSTEM CONFIGURATIONS  1  1-1 Standard system configuration This system is constructed with a 2-line communication system and a 2-line video system and requires minimal work for installation. The system is  constructed with video trunk lines consisting of a maximum of 6 trunks from the video bus control system and communication trunk lines tha
                    
                    Resumen del contenido incluido en la página 5 
                    
                        W P W P W P W P D A M J G T D A M J G T D A M J G T D A M J G T X Q X Q X X Q Q 1 2 3 B E H4 5 K 6 N 7 8 9 U 0 1 2 B 3 E 4 5 6 H K N 7 8 9 U 0 1 2 3 B E 4 5 6 H K N 7 8 9 U 0 1 2 3 B E 4 5 6 H K N 7 8 9 U 0 1-2 Expanded system configuration diagram The wiring of the sub trunk line is the same as the standard system. Common area Audio signal line (1) Video signal line (1) Power supply line (1) Residence trunks Residence trunks Residence trunks Residence trunks #1 #2 #3 #4 #5 #6 #1 #2 #3 #4 #5 #6 #
                    
                    Resumen del contenido incluido en la página 6 
                    
                        1-3 Residential station configuration For wiring from the control units to each residence, station-to-station wiring or star wiring using a 4-way video junction unit is possible.  Mixing on the same trunk line is not possible. Audio signal line (1) Video signal line (1) Power supply line (1)  Trunk line #1 Trunk line #2 Trunk line #3 to #6 Homerun wiring Station-to-station wiring 4-way video junction unit GT-4Z Each   residence Each   residence Each  Each  Each  Each   residence residence residen
                    
                    Resumen del contenido incluido en la página 7 
                    
                        AI PHONE JF-DVF Each residence (with recording function) Master monitor station   Door station  (with recording function) Video door station or doorbell GT-2C-L, GT-2C    GT-D Sub master monitor  station GT-2H-L, GT-2H PS24 Power supply-related [When sub master monitor stations are connected]  If even just one sub master monitor station is connected, it is possible to supply power to up to 2  residences with 1  power supply. However, wiring must be connected from near the terminals of the power 
                    
                    Resumen del contenido incluido en la página 8 
                    
                        W P W P W P W P D A M G T D A M J G T J A M D J G T D A M J G T X Q X Q X Q X Q 1 2 3 B E 4 5 6 H K N 7 8 9 U 0 1 2 3 B E 4 5 6 H K N 7 8 9 U 0 1 2 B 3 E 4 H 5 K 6 N 7 8 U 9 0 1 2 B 3 E 4 H 5 K 6 N 7 8 U 9 0 1-4 Wiring distance Standard system Expanded system Each  Each residence (with recording function) residence   Each  residence     PS24   * Each   residence DP  PS24      Each  residence       PS24 *  DP    DP  PS24      PS24    Entrance station   Entrance station   PS24 PS24   PS24 PS24 * E
                    
                    Resumen del contenido incluido en la página 9 
                    
                        Wire diameter 0.65 mm 0.8 mm 1.0 mm Wiring distance (22 AWG) (20 AWG) (18 AWG) [1] GT-BC - DP *2 3 m (10') 5 m (16') 5 m (16') [2] Entrance station - DP *2 150 m (490') 300 m (980') 300 m (980') [3] Entrance station - GT-VBC 150 m (490') 300 m (980') 300 m (980') [4] GT-MK - DP *2 150 m (490') 300 m (980') 300 m (980') [5] DP *2 - farthest residential station (includes system with GT-4Z) 150 m (490') 300 m (980') 300 m (980') [6] GT-VBC - farthest residential station (includes system with GT-4Z)
                    
                    Resumen del contenido incluido en la página 10 
                    
                        COMPONENTS  2  2-1 Entrance Station (Unit type) Panel Module Speech module (guidance-enabled  Speech module panel   type)   (guidance-enabled type) GT-DP-L GT-DA-L (connector included) Speech module   Speech module panel   GT-DA   GT-DP (connector included) Camera module   Camera module panel   GT-VA   GT-VP (connector included) 1-call button panel  2-call button panel   GF-1P GF-2P Switch module   GT-SW   (connector, name card included) 3-call button panel  4-call button panel   GF-3P GF-4P Nam
                    
                    Resumen del contenido incluido en la página 11 
                    
                        W P W P D A M J G T D A M J G T X Q X Q Mounting parts 4-module front Mounting bracket  frame  (included with Screws GT-4F GT-4F) 3-module front Mounting bracket 2-module front  Mounting bracket   frame  (included with frame   (included with GF-2F) GF-3F GF-3F) GF-2F Joint pipe  2-module back  4-module back box 3-module back box  box   GT-4B GF-3B GF-2B Mounting gauge Hooded surface- Rain hood  Surface-mount box  mount box   GT-nH GF-nBA GT-nHB 80 cm (32") connection cable  GF-C * A number appea
                    
                    Resumen del contenido incluido en la página 12 
                    
                        2-2 Entrance Station (Integrated type) USB cable A-B type (1 m) Flush mount entrance station (name scrolling, guidance-enabled, VIGIK-linked  type)   GT-DMV Flush mount entrance station (name scrolling, guidance-enabled)   GT-DM     Screws   Special screwdriver 2-3 Bus control unit etc. • Installation manual CD • Entrance station + security guard station operation manual • GT-2C (-L) GT-2H (-L) operation manual Bus control unit  Special  English, French    • GT-1C (-L) operation manual GT-BC scr
                    
                    Resumen del contenido incluido en la página 13 
                    
                        W P D A M J G T X Q 1 2 3 B E 4 5 6 H K N 7 8 U 9 0 Residential station   GT-1A Wood mounting   screws Screws Residential station GT-1D Optional handset   GT-HS Residential monitor station with  handset   Option connector GT-1M-L 2-5 Door station For door stations other than the GT-D, see the instruction manual for that door station. Wood mounting screws Door station   GT-D Screws 2-6 Security guard station Wood mounting  Security guard   screws station Option connector USB cable A-B type (1 m) 
                    
                    Resumen del contenido incluido en la página 14 
                    
                        MOUNTING  3  3-1 Mounting locations • For video entrance stations and video door stations, the picture quality of residential station monitoring is affected by the nature of the external light  from above and the surrounding area of the built-in cameras, so do not install these stations in the types of locations shown below. • Locations exposed to direct sunlight • Locations under street lights or door lights • Other locations exposed to strong light • Install master monitor stations and sub mas
                    
                    Resumen del contenido incluido en la página 15 
                    
                        3-3 Mounting positions and image view area  When using the camera module, if the rain hood is attached a portion of it will show up in the camera display. Mounting position 1350 mm (4' 4") Mounting position 1550 mm (5' 1") Wide picture Up/Down Approx. 2000 mm Approx. 1800 mm (6' 7") (5' 11") Camera center Approx. 1050 mm (3'5") Approx. 1050 mm (3'5") Camera center Approx. 950 mm Approx. 750 mm (3' 2") 1550 mm (5'1") 1350 mm (4'4") (2' 5") 500 mm (20") 500 mm (20") Left/Right Approx. 170  An area
                    
                    Resumen del contenido incluido en la página 16 
                    
                        3-4 Entrance Station (Unit type) Joint pipe 1 Make a hole for the cable.   2 Use the joint pipe to assemble the back box. Back box • Make sure the back box is mounted level. Joint pipe Back box assembly dimensions Back box GT-4B Back box GF-3B GF-2B/3B W W Back box GF-2B GT-4B (mm) (inch) x 1 110 4-5/16" x 2 245 9-5/8" x 3 380 15" 295 mm 200 mm 400 mm (11-5/8") x 4 515 20-1/4" (7-7/8") (15-3/4") x 5 650 25-9/16" x 6 785 30-7/8" 25 mm x 7 920 36-1/4" (1") 25 mm 25 mm (1") (1") x 8 1055 41-9/16" W
                    
                    Resumen del contenido incluido en la página 17 
                    
                             6 Remove the terminal cover.           7 From the speech module to the next module, insert the attached connector into the  socket.                             Make sure to run the cable under the terminal cover for protection.  8 Connect the connectors between the modules with cables.    Mount modules on the back boxes.   Example of interconnection of modules     Use the GF-C to connect to the name scrolling module.    To position the speech module in the center row, run the    GF-C throug
                    
                    Resumen del contenido incluido en la página 18 
                    
                        3-5 Entrance Station (Integrated type)    1 Open the cover and connect the wiring to the terminal block. Insert the wire into the direct terminal. If it is difficult to insert the wire, insert it while  pressing the release button.  2 Close the cover until it clicks into place. Flush mount  back box Unit  125 mm (4-15/16") 3 Mount the unit in the flush mount back box. 380 mm (15") Special  screwdriver  4 Tighten the locking screws using the special screwdriver. Mounting screws  60 mm (2-3/8") ×4 -
                    
                    Resumen del contenido incluido en la página 19 
                    
                        3-6 Bus control unit, 4-way video junction unit and power supply DIN rail mounting  The length of the connecting cable between the GT-BCX and GT-VBX is 40 cm. Therefore, mount them adjacently to each other. 1 Mount the unit on the DIN rail. Click the unit into place. 2 When removing the unit, pull the lock release lever down.  * When the system does not operate properly, check the wiring.   Turn off the GT-BC and GT-VBC power switch and then turn the switch back on after four seconds.   This wil
                    
                    Resumen del contenido incluido en la página 20 
                    
                        3-7 Residential station  Mounting screws ×4 3-gang box     83.5 mm  (3-5/16")  Mounting bracket 1. Press the release button  (to insert or remove the wire).  2. Insert the cable into the terminal.   •  To remove the terminal block, slide the  terminal block and pull it out.  • Strip a way the jacket of the cable and in- 8 mm sert all wires into the slots in an orderly  (3/8") fashion. Failure to do so could result in  pinching that may damage the wiring. Surface wiring * When a 3-gang box is not