3ware 9690SA  
SAS/SATA RAID 
Controller 
PN 720-0185-00
August 2008
Installation Guide                                                                                                                                                                                                                                                                                                                                                                                                                          
                    
                    Resumen del contenido incluido en la página 2 
                    
                        Copyright  ©2004-2008 Applied Micro Circuits Corporation (AMCC). All  rights reserved. This publication may be copied or reproduced for  reference purposes only. All other purposes require the express  written consent of AMCC, 215 Moffett Park Drive, Sunnyvale, CA  94089. AMCC shall not be responsible or liable for, and shall be  held harmless against, any and all damages, claims, and/or disputes  that arise from the copying or reproduction of this publication. Trademarks 3ware®, Escalade®, 3DM®
                    
                    Resumen del contenido incluido en la página 3 
                    
                        Table of Contents About this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv Chapter 1. Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Contents of this Package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 9690SA RAID Controller Card Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    Resumen del contenido incluido en la página 4 
                    
                        About this Guide Congratulations on your purchase of the 3ware® 9690SA SAS  RAID Controller. This guide tells you how to install it. Chapter Description 1 Getting Started Overview of the 3ware RAID controller and  important safety factors to keep in mind during  installation 2 Installing Your 3ware How to install your 3ware RAID controller RAID Controller 3 Installing a Battery How to install and maintain a BBU Backup Unit The following additional documentation is available for your 3ware  RAID 
                    
                    Resumen del contenido incluido en la página 5 
                    
                        Chapter 1. Getting  Started The 3ware® 9690SA SAS RAID controller provides these features:   Support for up to 128 SAS and/or SATA devices  RAID 6 with simultaneous parity generation to maximize  performance  8th-generation StorSwitch™ switch fabric for maximum  controller output  StreamFusion™ optimization of RAID 5 and RAID 6 disk  accesses to maximize application performance under heavy  loads  StorSave Battery Backup Unit (BBU) with write journaling to  optimize data protection and performan
                    
                    Resumen del contenido incluido en la página 6 
                    
                        Chapter 1. Getting Started  This document, 3ware 9690SA SAS/SATA RAID Controller  Installation Guide  3ware CD-ROM with driver, software, and additional  documentation  Appropriate cables for your 3ware 9690SA model.  9690SA-4I (one internal SFF-8087 to SFF-8087 cable)  9690SA-8I or 9690SA-8IF (two internal SFF-8087 to SFF- 8087 cables)  9690SA-8E (two external SFF-8088 to SFF-8088 cables)  9690SA-4I4E (one internal SFF-8087 to SFF-8087 cable  and one external SFF-8088 to SFF-8088 cable) If you 
                    
                    Resumen del contenido incluido en la página 7 
                    
                        9690SA RAID Controller Card Models Figure 2.  8-Port 3ware 9690SA-8I Serial ATA RAID Controller 2 BBU connector and hole for post I C connector Two internal  Multi-lane  connectors Heat Sinks Figure 3.  8-Port 3ware 9690SA-8IF Serial ATA RAID Controller   2 2 1 I C connector I C jumper BBU connector and hole for post Two internal  Multi-lane  connectors Buzzer Buzzer  Jumper Heat Sinks 1   Enables on board MUX if jumper is installed. www.3ware.com 3                                               
                    
                    Resumen del contenido incluido en la página 8 
                    
                        Chapter 1. Getting Started Figure 4.  8-Port 3ware 9690SA-8E Serial ATA RAID Controller Two external Multi-lane  connectors BBU connector and hole for post Heat Sinks Figure 5.  8-Port 3ware 9690SA-4I4E Serial ATA RAID Controller BBU connector and hole  One external Multi-lane  2 I C  connector One internal  Multi-lane  connector Heat Sinks Cables Important: You should only use AMCC/3ware certified cables  with your 3ware RAID controller. Using an incorrect cable can  result in drives that are n
                    
                    Resumen del contenido incluido en la página 9 
                    
                        Cables SFF-8087-to-SFF-8087 Multi-lane cables  Use with an internal connector of the 9690SA-8I, 9690SA-8IF,  9690SA-4I, or 9690SA-4I4E 3ware RAID controller. These cables are for use with a multi-lane-enabled drive backplane  that has the SFF-8087 mini SATA/SAS 4i connectors. These cables  have multi-lane cable plug connectors on each end (Figure 6). Figure 6.  Multi-lane Cable Serial ATA (SFF-8087) SFF-8088 to SFF-8088 Multi-lane cables For use with the 9690SA-8E and 9690SA-4I4E 3ware RAID  con
                    
                    Resumen del contenido incluido en la página 10 
                    
                        Chapter 1. Getting Started System Requirements Motherboard and Slot Requirements A workstation-class or server-class motherboard with an x8 or x16  PCI-Express® slot. A list of systems that have been tested is  available at http://www.3ware.com/products/sys_compatibility.asp Enclosure Requirements  In order to attach more than four drives per connector, enclosures  with expanders are required.  In order to use enclosure support services, such as locating a drive  by blinking an LED or notificati
                    
                    Resumen del contenido incluido en la página 11 
                    
                        System Requirements Operating System Requirements  Windows XP, Windows Server 2003 (32-bit and 64-bit x86),  Windows Server 2008 (32-bit and 64-bit x86), Windows Vista  (32-bit and 64-bit x86)  Red Hat Linux, 32-bit and 64-bit x86  SuSE Linux, 32-bit and 64-bit x86  Fedora Core, 32-bit and 64-bit x86   FreeBSD, 32-bit and 64-bit x86  Other versions of Linux, 32-bit and 64-bit x86, using the open  source Linux 2.4 or 2.6 kernel driver   VMware ESX 3.x Server For the latest driver versions for all
                    
                    Resumen del contenido incluido en la página 12 
                    
                        Chapter 1. Getting Started Safety Information  To reduce the risk of bodily injury, electrical shock, fire, and  equipment damage, read this information and observe all warnings  and precautions in this guide before installing or maintaining your  computer. The 3ware 9690SA RAID controller card should be installed by  technically qualified persons. If you are uncomfortable opening a  computer system and conforming to standard ESD (electrostatic  discharge) practices, you should have a computer t
                    
                    Resumen del contenido incluido en la página 13 
                    
                        Safety Information Personal Safety When Installing the 9690SA RAID  Controller in Your Computer Warning! High voltages may be found inside computer  equipment.  Before installing any of the hardware in this package or  removing the protective covers of any computer equipment, turn  off power switches and disconnect power cords. Do not  reconnect the power cords until the hardware is installed and the  system cover is closed. Protecting Equipment and Data  Heat Sink Warning. Do not replace the fa
                    
                    Resumen del contenido incluido en la página 14 
                    
                        Chapter 1. Getting Started Installation Considerations Air Flow, Cable Length, and Routing Space Adequate airflow and ventilation are particularly important for  3ware 9690SA RAID controllers. The on-board heat sink collects  heat, and must have adequate airflow in order to disburse it. It is  important that the cables do not obstruct the air flow or prevent  proper ventilation of the system. Selecting the Slot in Which to Install the Controller Consider these factors when deciding on the slot i
                    
                    Resumen del contenido incluido en la página 15 
                    
                        Chapter 2. Installing  Your 3ware RAID  Controller Tools You Need You will need the following tools during installation:  An ESD grounding strap or mat  A Phillips screwdriver  Before You Start 3ware 9690SA RAID controllers can be installed in a standard  enclosure or in an enclosure with a backplane. 1 Be sure to read “Safety Information” on page 8 in Chapter 1. 2 If you have a Battery Backup Unit (BBU), install it before  proceeding. For details, see “Chapter 3. Installing a Battery  Backup Un
                    
                    Resumen del contenido incluido en la página 16 
                    
                        Chapter 2. Installing Your 3ware RAID Controller Install the Controller in the Computer 1 If the computer is running, shut it down. Turn off power to the  computer and disconnect the power cord from the outlet. 2 Make sure you are properly grounded. (For details about safety  precautions, see page 8.) 3 Open the computer case according to the manufacturer’s  instructions. 4 Locate the PCI Express slot you want to use for the 3ware  9690SA RAID controller.  For a discussion of which slot to use, 
                    
                    Resumen del contenido incluido en la página 17 
                    
                        Install the Controller in the Computer 7 Press down gently on the edge of the 3ware RAID controller  directly above the PCI Express slot until it is fully seated. Figure 8.  Inserting Controller Into PCI Express Slot Use a PCI  Express slot for  the 3ware  9690SA  controller. If in doubt about what slots you  have, check the  documentation  for your  motherboard. Do NOT  use a PCI or   PCI-X slot. 8 Check that the 3ware RAID controller’s metal bracket covers  the hole in the case and secure the 
                    
                    Resumen del contenido incluido en la página 18 
                    
                        Chapter 2. Installing Your 3ware RAID Controller Attach the Cables to Your Controller The internal and external connectors of the 9690SA RAID  controller accept different cable connector plugs. Internal Connectors The 9690SA-8I, 9690SA-8IF, 9690SA-4I, and 9690SA-4I4E  controller cards have internal connectors and use the SFF-8087  cable.  Insert the SFF-8087 cable plug into the multi-lane connector on  the controller. When the cable is inserted correctly, you will feel it click into  place. Figu
                    
                    Resumen del contenido incluido en la página 19 
                    
                        Connect the Cables to Backplanes External Connectors The 9690SA-8E and 9690SA-4I4E controller cards have external  connectors and use the SFF-8088 cable.  Insert the SFF-8088 cable plug connector into the multi-lane  external connector of the controller. When the plug is inserted correctly, you will feel it click into  place. Figure 10.  Connecting a Multi-lane Cable with an SFF-8088  Connector to the 9690SA-8E Controller Connect the Cables to Backplanes  After installing your 3ware RAID control
                    
                    Resumen del contenido incluido en la página 20 
                    
                        Chapter 2. Installing Your 3ware RAID Controller Note: If your backplane has individual connections for each  drive, or if you do not have a backplane, you can directly  connect up to 4 drives per internal connector through use of a  breakout cable. Finishing Up the RAID Controller  Installation After you have installed the controller in the computer and attached  appropriate cables to the controller and drives, complete the  following steps to complete the hardware installation. Connect Battery