Résumé du contenu de la page N° 1 
                    
                         FACSIMILE RECEIVER
FAX-410                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         
                    
                    Résumé du contenu de la page N° 2 
                    
                        IMPORTANT NOTICE    • This manual is intended for use by native speakers of English.   • No part of this manual may be copied or reproduced without written permission.  • If this manual is lost or worn, contact your dealer about replacement.  • The contents of this manual and equipment specifications are subject to change without  notice.  • The example screens (or illustrations) shown in this manual may not match the screens  you see on your display. The screen you see depends on your system co
                    
                    Résumé du contenu de la page N° 3 
                    
                        SAFETY INSTRUCTIONS Safety Instructions for the Operator WARNING WARNING Do not open the equipment except to Use the proper fuse. replace paper. Use of a wrong fuse can result in damage Only qualified personnel should work to the equipment or cause fire. inside the equipment. Handle the LCD with great care. Strong Immediately turn off the power at the shock may break it. switchboard if water leaks into the equipment or something is dropped If the LCD breaks, LCD liquid may leak out. into the equ
                    
                    Résumé du contenu de la page N° 4 
                    
                        Safety Instructions for the Operator (con't) WARNING LABEL A warning label is attached to the main unit.  Do not remove the label. If the label is missing or  damaged, contact a FURUNO agent or dealer about replacement. Name: Warning Label 1 WARNING To avoid electrical shock, do not Type: 86-003-1011-1 remove cover. No user-serviceable  Code No.: 100-236-231 parts inside. Safety Instructions for the Installer CAUTION WARNING Securely attach protective Observe the following compass safe earth to 
                    
                    Résumé du contenu de la page N° 5 
                    
                          CONTENTS    Page   1. OUTLINE ・・・・・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1  1.1 Characteristics  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1  1.2 List of Standard Components ・・・・・・・・・・・・・・・・・・・・・ 2  1.3 System Components ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3    2. OPERATION  2.1 Description of key ・・・・・・・・・・・・・・・・・・・・・・・・・・・ 4  2.2 Contrast and brightness ・・・・・・・・・・・・・・・・・・・・・・・・ 7  2.3 Basic operation ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 7  2.3.1 Channel setting ・・・・・・・・・・・・・・・・・・・・・・・・・・・ 7  2.3.2 Fine-adjustment of frequ
                    
                    Résumé du contenu de la page N° 6 
                    
                            4.6 Exchange of a recording paper ・・・・・・・・・・・・・・・・・・・ 23  5. SPECIFICATIONS ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ SP-1  5.1 Receiver ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ SP-1  5.2 Recorder  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・  SP-1   5.3 Automatic Control ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ SP-1  5.4 Power, Dimension & Weight ・・・・・・・・・・・・・・・・・・・・・・ SP-1    APPENDIX  TABLE OF FACSIMILLE STATION  Area map of existing stations ・・・・・・・・・・・・・・・・・・・・・・ SP-2  Facsimile station table  ・・・・・・・・・・・・・・・・・・・・・・・・・・ SP-
                    
                    Résumé du contenu de la page N° 7 
                    
                        1.OUT LINE  FAX-410 is the high sensitive weather facsimile receiver using electronic scanning  thermal head recording system.    1.1 Characteristics  (1)  Electronic scanning with thermal head recording system provides clear image, quiet  operation.  (2) Pre-programmed all existing weather facsimile stations in the world.  Vacant  channels for new station are provided, and rewriting of the memory data is possible  for changing frequency of existing station.   (3)  9-tones gradation recording fu
                    
                    Résumé du contenu de la page N° 8 
                    
                        1.2 List of Standard Components    Facsimile receiver. List of Standard Components      Standard Components   Name Model nam Q’ty Remarks  e/Code No. 1 set Main unit FAX-410 AC Power supply or DC Power supply   1  Installation materials    1 set Accessories   1 set Spare parts          Installation materials   Name Model nam Q’ty Remarks  e/Code No. 2m  Grounding wire 343200G01 With terminal  2  Coaxial connector M207-P For Antenna cable  4  Self-tapping screw M5×25 Clamp for Main unit  5  Flat 
                    
                    Résumé du contenu de la page N° 9 
                    
                        1.3 System Components                                                          2.6m Whip antenna          Antenna  coupler,fax-5              To BK line    To Grounding wire    To Power supply  Coaxial cable                                                               Main unit                         3                                                                                                                                                                                                   
                    
                    Résumé du contenu de la page N° 10 
                    
                            2.OPERATION  The unit, with antenna(s) and power supply, receives and records signal automatically  by the control of APSS when desired channels have been set.  2.1 Description of key  Program key : For preparation to mode setting.  PRG   One of following modes can be selected by pressing   N  PRG key and next, a       key.  0~9  Be sure to follow instruction of the indicator in  selecting a mode.  To cancel a setting, press the  PRG  key to reset to the initial display of selection mode.   
                    
                    Résumé du contenu de la page N° 11 
                    
                              IOC key : For selection of IOC.  IOC               Up key : Channel up in the channel mode or frequency up in  2  the frequency mode.       Left key : For manual phasing in recording (towards left).  4      A press of the key shifts 2.5% of the paper width.      Right key : For manual phasing in recording (towards right).  6    A press of the key shifts 2.5% of the paper width.      Down key : Channel down in the channel mode or frequency  8  down in the frequency mode.                    
                    
                    Résumé du contenu de la page N° 12 
                    
                                Channel key : For selection of  channel mode from frequency  CH  mode, and for shift to the channel setting in the  channel mode. For setting a channel,  press       key and enter channel number with  CH N three      keys.  0~9 The channel covers 000~406 (existent frequency)  and 410~733 (new frequency).                                  Clear key : For deletion of memorized value in a set mode and  C  for return to the standard operation mode from a  set mode.               Record key : 
                    
                    Résumé du contenu de la page N° 13 
                    
                            2.2 Contrast and brightness  Contrast of LCD display depends on the visual angle and the temperature and hence,  be sure to adjust it with the contrast knob (see Fig. 1) for optimum result at the time  of installation.  The backlight brightness of the LDC can be adjusted in five stages by  pressing the        key.  DIM     2.3 Basic operation  Power switch is on the left of the front panel.  When the power is turned on, the  channel at the last power off is displayed.      C000 JMH 3622.5  T
                    
                    Résumé du contenu de la page N° 14 
                    
                            within 2000.0~24999.9kHz).  2.3.3 Start and stop of recording  (1) Start  Recording starts automatically (Start/Stop, Phase, Speed, IOC) by receiving the  APSS signal.  To start halfway of the received picture, press        key once  RCD  and automatic speed setting and auto-phasing mode are set.  Then, recording  starts upon phasing is completed.  When the phase signal for automatic start is  not received, recording does not start.  Then, press        key again for manual  RCD recording.  (
                    
                    Résumé du contenu de la page N° 15 
                    
                            2.3.6 Selection of reception mode  The reception mode refers IOC, speed, and normal/reverse printing and modes.   The former two (IOC and speed) are automatically selected by receiving the APSS  signal and phase signal.  For the latter two modes, desired ones should be selected  manually.  (1) Speed and IOC  When incorrect speed or IOC is selected in  manual recording or when auto-recording  has started at improper position, its setting  can be changed with following procedure.  a) Change of
                    
                    Résumé du contenu de la page N° 16 
                    
                            To release this timer or keylock in the timer mode, follow the procedure below.  (1) In the timer standby mode (time for the next recording is displayed):  PRG Press       key then the message on the   TIMER RCV : OFF ?  right is displayed. Then,   PUSH E KEY  a press of       key releases the timer   E  operation and shifts the mode to the  standard operation mode.    By pressing          key before fix the timer release, the   C  timer standby mode is maintained.  (2) In the timer operatio
                    
                    Résumé du contenu de la page N° 17 
                    
                            receiver, 2 is for external receiver.  Pressing  N the      key after setting a      key,   E  0~9 completes the setting.  2.4.2 Setting of timer reception  This unit has 16 booking functions and each timer is set as follows.  Press       key. Then the timer reception setting mode is set and the message is   2  shown on the right.The displayed number correspond to the following entries  respectively.   TIMER  RCV : 1-OFF   1 : Release   2-ON 3-RCL  4-STR   2 : Setting   3 : Re-calling (reado
                    
                    Résumé du contenu de la page N° 18 
                    
                            (4) Entry booking  Press     4    key.   STORE  TIMER  REG Select a timer number for booking by pressing    SET  REG  NO.  0- F               key.  Then, the unit will ask   △  ▽ whether the number is correct or not.  Fix  the number by pressing the       key or   E   R1  SET  CHANNEL  enter a new number if the number is not   NO.  in  3  FIGURES correct.  The display on the right shows  when the number 1 is set.  N N Then, enter a channel number with three       keys (or press two       key
                    
                    Résumé du contenu de la page N° 19 
                    
                            the following operations.   SLEEP MODE : OFF   1 : Release   1-OFF 2-ON   2 : Setting  (1) Release  Select “1” in the above message, and fix with   SLEEP MODE : OFF ?         key.  (display on the right)   E    PUSH  E  KEY  Note: When the system is in the sleep mode,  PRG  press        &    E   keys to shift  the mode to the standard operation  mode.  (2) Setting  Select “2” in the above message, and enter   SLEEP TIME :   N desired time to sleep by       key (max.  0~9  SET  SLEEP  TIME  2
                    
                    Résumé du contenu de la page N° 20 
                    
                                SET SPEED  120-60 SET REVERSE        1-120  2-90  3-60                1-0FF     2-ON                             SET IOC 576/288 1-576  2-288        2.4.5 Time setting  Clock time can be set by the following procedure.  SET MONTH Pressing the      key sets the time    5  setting mode and message shown on the  by   /   KEY right appears.  Set month with            key, and fix it   △ ▽ APR with      key.   E  SET DATE in 2FIG The message on the right shows entering  April.  Next, enter da