Résumé du contenu de la page N° 1 
                    
                        ®
PowerScan D8530
Reference Manual                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Résumé du contenu de la page N° 2 
                    
                                Datalogic Scanning, Inc.  959 Terry Street  Eugene, Oregon 97402  USA  Telephone: (541) 683-5700  Fax: (541) 345-7140        An Unpublished Work - All rights reserved. No part of the contents of this  documentation or the procedures described therein may be reproduced or  transmitted in any form or by any means without prior written per-mission of Datalogic  Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).  Owners of Datalogic products are hereby gr
                    
                    Résumé du contenu de la page N° 3 
                    
                                    CONTENTS        GENERAL VIEW .......................................................................................... v COMPLIANCE.............................................................................................. v  FCC Compliance...........................................................................................vi  Laser Safety..................................................................................................vi  WEEE Compliance ...................
                    
                    Résumé du contenu de la page N° 4 
                    
                        3.2 Wedge Interface Selection.......................................................................... 13  3.3 USB Interface Selection.............................................................................. 14  4 CONFIGURATION USING CODE SYMBOLS ........................................... 17  4.1 Default Settings........................................................................................... 18  4.2 Changing Default Settings .....................................................
                    
                    Résumé du contenu de la page N° 5 
                    
                        GENERAL VIEW      Cable Connector  LEDs    POWERSCAN® D8530 Reader      COMPLIANCE        Aiming System Imager    Beam Output Window           POWERSCAN® D8530 Reader Product Labels  v                                                                                                                                                                                                                                                                                                                            
                    
                    Résumé du contenu de la page N° 6 
                    
                        CE COMPLIANCE    This is a Class A product . In a domestic environment this product  may cause radio interference, in which case the user may be    required to take adequate measures.  WARNING     FCC COMPLIANCE    Modifications or changes to this equipment without the expressed written approval of  Datalogic could void the authority to use this equipment.    This device complies with Part 15 of the FCC Rules. Operation is subject to the  following two conditions: (1) This device may not cause h
                    
                    Résumé du contenu de la page N° 7 
                    
                        Aiming System    The PowerScan® D8530 aiming system meets the requirements for laser safety.    I D F E  LA LUCE LASER È DIE LASER- LE RAYON LASER EST LA LUZ LÁSER ES  VISIBILE ALL'OCCHIO STRAHLUNG IST FÜR VISIBLE À L'OEUIL NU VISIBLE AL OJO  UMANO E VIENE DAS MENSCHLICHE ET IL EST ÉMIS PAR HUMANO Y ES  EMESSA DALLA AUGE SICHTBAR UND LA FENÊTRE EMITIDA POR LA  FINESTRA INDICATA WIRD AM STRAHLAUS- DÉSIGNÉE SUR VENTANA INDICADA  NELLA FIGURA. TRITTSFENTSTER L'ILLUSTRATION DANS EN LA FIGURA.  AUSGE
                    
                    Résumé du contenu de la page N° 8 
                    
                        ITALIANO  Le seguenti informazioni vengono fornite dietro direttive delle autorità internazionali e  si riferiscono all’uso corretto del terminale.    NORMATIVE STANDARD PER LA SICUREZZA LASER  Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla data  di produzione: CDRH 21 CFR 1040 e EN 60825-1.  Non si rende mai necessario aprire l’appa-recchio per motivi di installazione, utilizzo  o manutenzione.    L'utilizzo di procedure o regolazioni differenti da quelle des
                    
                    Résumé du contenu de la page N° 9 
                    
                        NORMES DE SECURITE LASER  Ce produit est conforme aux normes de sécurité laser en vigueur à sa date de  fabrication: CDRH 21 CFR 1040 et EN 60825-1.  Il n’est pas nécessaire d’ouvrir l’appareil pour l’installation, l’utilisation ou l’entretien.    L'utilisation de procédures ou réglages différents de ceux donnés  ici peut entraîner une dangereuse exposition à lumière laser    visible.  ATTENTION    Le produit utilise une diode laser. Aucun dommage aux yeux humains n’a été  constaté à la suite d’
                    
                    Résumé du contenu de la page N° 10 
                    
                        WEEE COMPLIANCE    Waste Electrical and Electronic Equipment (WEEE) Statement        English  For information about the disposal of Waste Electrical and Electronic Equipment  (WEEE), please refer to the website at www.scanning.datalogic.com.    Italian  Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche  consultare il sito Web www.scanning.datalogic.com.    French  Pour toute information relative à l’élimination des déchets électroniques (WEEE),  veuillez consult
                    
                    Résumé du contenu de la page N° 11 
                    
                        POWER SUPPLY    This device is intended to be supplied by a UL Listed or CSA Certified Power Unit  marked "Class 2" or "LPS" output rated 5-30  V, minimum 0.75 A which supplies  power directly to the scanner via the jack connector on the cable.        PATENTS      This product is covered by one or more of the following patents:    Design Pat.: AU 310201; AU 310202; CN 693980; HK 0602013.5M001; HK  0602013.5M002; JP 1305693; KR 30-0460940.    US Pat.: 6,478,226 B2; 6,512,218 B1; 6,808,114 B1; 6,8
                    
                    Résumé du contenu de la page N° 12 
                    
                          SERVICE AND SUPPORT    Datalogic provides several services as well as technical support through its website.  Log on to www.scanning.datalogic.com and click on the links indicated for further  information including:  • PRODUCTS  Search through the links to arrive at your product page where you can  download specific Manuals and Software & Utilities including:  - Datalogic Aladdin™ a multi-platform utility program that allows device  configuration using a PC. It provides RS-232 interface config
                    
                    Résumé du contenu de la page N° 13 
                    
                        INTRODUCTION  1 INTRODUCTION      1.1 POWERSCAN® D8530 FAMILY DESCRIPTION    The PowerScan® D8530 Family Hand-Held Reader packs a lot of performance into  an attractive, rugged, hand-held device. It operates in commercial and industrial  environments as well as the front office.    Omni-directional To read a symbol or capture an image, you simply aim the  Operating reader and pull the trigger. Since PowerScan® D8530 Family  is a powerful omni-directional reader, the orientation of the  symbol is
                    
                    Résumé du contenu de la page N° 14 
                    
                        POWERSCAN® D8530  1.3 CONFIGURATION METHODS    1.3.1 Reading Configuration Codes    This manual can be used for complete setup and configuration. If you wish to change  the default settings, you can configure the PowerScan® D8530 reader by reading the  programming code symbols in this manual. Configuration commands and their  relative arguments are read individually using the symbols in this manual. See  Appendix D.      1.3.2 Using Datalogic Aladdin™    The Datalogic Aladdin™ program, available
                    
                    Résumé du contenu de la page N° 15 
                    
                        INTRODUCTION    1.4 CABLE CONNECTION                                                      A. Rubber gasket  B. Plastic boot   C. Cable spacer  D. Cover  E. Strain relief    3                                                                                                                                                                                                                                                                                                                                      
                    
                    Résumé du contenu de la page N° 16 
                    
                        POWERSCAN® D8530  Follow the given procedure for correct cable insertion:    3  Align  2  5 1  6 Notch 4 7  Arrow  Tab         Slip the cover over the cable.   Push the plastic boot into the rubber gasket. Take care that the tab on the plastic  boot is aligned with the notch in the rubber gasket.   Push the plastic boot and gasket into the handle. Ensure that the “Front” marking  on the plastic boot is facing out, with the arrow pointing towards the front of the  scanner.   Insert the cable into
                    
                    Résumé du contenu de la page N° 17 
                    
                        USING POWERSCAN® D8530  2 USING POWERSCAN® D8530      2.1 AIMING SYSTEM    The PowerScan® D8530 reader uses an intelligent aiming system similar to those on  cameras. By partially pulling the trigger, the aiming system indicates a field of view to  be positioned over the code:        Figure 1 - Aiming System    When you pull the trigger completely a red beam illuminates the code. If the aiming  system is centered and the entire symbology is within the aiming system, you will get  a good read. Th
                    
                    Résumé du contenu de la page N° 18 
                    
                        POWERSCAN® D8530  The field of view indicated by the aiming system will be smaller when the  PowerScan® D8530 is closer to the code and larger when it is farther from the code.  Symbologies with smaller bars or elements (mil size) should be read closer to the  unit. Symbologies with larger bars or elements (mil size) should be read farther from  the unit. (See chapter 8 for further details).      2.2 NORMAL OPERATION    PowerScan® D8530 normally functions by capturing and decoding codes.     Poi
                    
                    Résumé du contenu de la page N° 19 
                    
                        USING POWERSCAN® D8530  You can use the aiming system to position the reader from the object (ensure the  reader is about centered over the target). Adjust the distance at which you are  holding the reader (see Figure 2).    If the RS-232 interface has been selected, the image will be transferred to the host  PC via XMODEM_1K protocol.    Image capturing is not available in Wedge and USB Keyboard  Emulation interfaces and is not compatible with Autoscanning nor    when the Software trigger type 
                    
                    Résumé du contenu de la page N° 20 
                    
                        POWERSCAN® D8530  2.3.2 Advanced Configuration Parameters      By default, for all Image Presets, the window has its origin coordinates equal to zero,  its width equal to 1280 pixels and its height to 1024 pixels.    Brightness Adjustment is available in the range from –100% up to 100%, in steps of  1%. Positive values shift the luminance up so that the image will result brighter.  Default value is 0%, meaning that no brightness adjustment is performed.    The same range of values (–100% up to 1