Résumé du contenu de la page N° 1
EVERFOCUS
1/3” 560 TVL High Resolution
Color Rugged Dome Camera
Operation Instructions
Model No. EHD350
Please read this manual first for correct installation and operation. This manual should be retained
for future reference. The information in this manual was current when published. The
manufacturer reserves the right to revise and improve its products. All specifications are therefore
subject to change without notice.
PRECAUTIONS
1. Do not install the camera near elec
Résumé du contenu de la page N° 2
the camera body. Use lens tissue or a cotton swab and ethanol to clean the sensor and the camera lens. 7. Do not operate the camera beyond the specified temperature, humidity or power source ratings. Use the camera at temperatures within –40℃ ~ 50℃ (-40F ~122F) and humidity between 20%~ 80%. The input power source is 12VDC/24VAC. PREFACE The most technically advanced EHD series are the newest vandal-resistant Color Rugged Dome Camera from EverFocus Electronics. The Color Rugged Dom
Résumé du contenu de la page N° 3
Desiccant Pack x 1 Manual x 1 Optional Accessory Wall Mount Bracket (BA-EHD) SPECIFICATIONS Pickup Device 1/3'' SONY Super HAD CCD Video Format NTSC or PAL NTSC: 525 TV lines, 60 fields/sec Scanning System PAL: 625 TV lines, 50 fields/sec Picture Elements 768 x 494(NTSC) ; 752 x 582(PAL) Horizontal Resolution 560TVL Sensitivity 0.5Lux/F=1.2 S/N Ratio Over 48dB(AGC off) Electronic Shutter 1/50(1/60)~1/100,000 Vari-focal lens, Auto Iris f=2.9~10mm, F=1.2 Lens Type f=3.8~9
Résumé du contenu de la page N° 4
24VAC: 20.5VA max. (heater ON ) 12VDC: 3.5W max. (heater OFF ) 12VDC: 11W max. (heater ON ) 130mm(W) x 98.8mm(H) x 130mm(D); Dimensions 5.1"(W) x 3.9"(H) x 5.1"(D) Weight 1.7kg ; 3.7lbs Operating Temperature -40°C~50°C ; -40°F~122°F (20%~80% Humidity) Certifications FCC/CE DIMENSIONS INSTALLATION 1. Loosen the 4 fix screws on the housing cover by using the attached wrench (Figure 1). Carefully uncap the housing cover as the direction shown below (Figure 2), ple
Résumé du contenu de la page N° 5
2. Remove the camera. Vari-Focal Lens Heater Locking Screws Figure 3 To remove the camera, first unplug the wire connection on the back of the camera. Then loosen the 2 locking screws on the camera base, push the camera base to the right (toward heater direction, as shown in Figure 3), remove the camera from the mounting base. Reinstall the camera and the cable while the base mounting is completed. 3. Mounting the base. Side conduit entry Conduit plug setscrew Back
Résumé du contenu de la page N° 6
Attach the base to the wall or ceiling, fix the base by the 4 setscrews attached in the accessory pack. The dome is weighted 1.7kg, please make sure if the mounting is strengthened enough to support it, if not, please reinforce the mounting according to the environment. Note: The diameter of the screw hole isψ4.7mm. Back conduit entry (PF1/2) The camera comes with a conduit plug pre-installed in the PF 1/2 conduit entry on the side. The screw can be removed and installed i
Résumé du contenu de la page N° 7
4. Re-assemble Camera 1. When mounting COLOR RUGGED DOME CAMERA on the wall, please aim the “Wall” in line with the triangle “ ” marked on the lead frame. (Factory default) Figure 6-1 “Wall” 2. When mounting COLOR RUGGED DOME CAMERA on the ceiling, please aim the “Ceiling” in line with the triangle “ ” marked on the lead frame. Figure 6-2 “Ceiling” 6 6
Résumé du contenu de la page N° 8
5. Wire Connection Termination Board Micro Switch for Alarm trigger Power In (+) GND Alarm COM Video Power In (-) Alarm NO V. Phase Adjustment VR Alarm NC Figure 7 Connect the power supply cable (AC24V/DC12V), video output and alarm output to the proper connectors shown as Figure 7. The V. Phase adjustment screw is located on the termination board. The vertical phase may require adjustment to synchronize the vertical phase of the camera with other cam
Résumé du contenu de la page N° 9
6. View Angle Adjustment The camera can be rotated 360° horizontally, 140° vertically and 60° 3’rd axis view angles (as shown in Figure 8). Adjust the proper camera view angle as needed. If a vari-focal lens is used, you may adjust the focus and zoom of the lens to bring the object in focus. Be sure to loosen the locking screws on the lens before you make adjustment. Lens fixing Screws 140° 360° 60° Figure 8 8
Résumé du contenu de la page N° 10
DIP SWITCH FUNCTION Vari-Focal Lens LL (Line-Lock) OFF/ON To select the sync mode between Internal Sync.(LL off) and Line-Lock (LL on). Set the line-lock off, the camera will synchronize to the internal time base. Set the line-lock ON, the camera’s vertical synchronization can be driven by the AC signal in the power lines. Note: Line-Lock sync mode operation is possible only when used with an AC power source; it is not possible with a DC power source. The default
Résumé du contenu de la page N° 11
BLC (Back Light Compensation) ON/OFF When BLC is turned on, the AGC, ES and IRIS operating points are determined by averaging over the center area instead of entire field-of-view, so that a dimly-lit foreground object at center area can be clearly distinguished from brightly-lit backgrounds. BLC should not be used unless it is needed to compensate for back-lit. The default setting is OFF. FL (Flickerless Function) ON/OFF When picture flicker fiercely, turn FL on, then the camera will
Résumé du contenu de la page N° 12
SIMPLE INSTRUCTIONS FOR THE DESICCANT PACK Due to the camera lens blurred from the humidity inside the camera. The desiccant pack absorbs the humidity; please refer to the easy instruction as follows: 1. Adjust all settings first and place the desiccant pack on the horizontal rod, then bend the horizontal rod and fix it. 2. Install the outer cover and tighten the screws. Installation steps for the EHD series: Step 1 Horizontal rod Desiccant pack Step 2 Be
Résumé du contenu de la page N° 13
EverFocus Electronics Corp. Head Office: Europe Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Albert-Einstein-Strasse 1 Hsi-Chih, Taipei, Taiwan D-46446 Emmerich, Germany TEL: +886-2-26982334 TEL: 49-2822-9394-0 FAX: +886-2-26982380 www.everfocus.de www.everfocus.com.tw China Office: Room 609, Technology Trade Building, USA L.A. Office: Shangdi Information Industry Base, Haidian 1801 Highland Ave. Unit A District, Beijing,China 10085 Duarte, CA 91010, U.S.A. TEL: +86-10-6297