Instruction d'utilisation Bally Refrigerated Boxes s/Freezers/Warmers

Instruction d'utilisation pour le dispositif Bally Refrigerated Boxes s/Freezers/Warmers

Dispositif: Bally Refrigerated Boxes s/Freezers/Warmers
Catégorie: Refrigérateur
Fabricant: Bally Refrigerated Boxes
Dimension: 1.46 MB
Date d'addition: 10/30/2014
Nombre des pages: 36
Imprimez l'instruction

Téléchargez

Comment utiliser?

Notre objectif consiste à vous assurer le plus rapide accès au contenu de l'instruction d'utilisation du dispositif Bally Refrigerated Boxes s/Freezers/Warmers. En utilisant l'aperçu en ligne vous pouvez parcourir le sommaire et passer à la page où vous trouverez la résolution de votre problème avec Bally Refrigerated Boxes s/Freezers/Warmers.

Pour votre confort

Si regarder l'instruction Bally Refrigerated Boxes s/Freezers/Warmers directement sur la page n'est pas confortable pour vous, vous pouvez profiter de deux solutions possibles:

  • Exploration au mode de plein écran - pour analyser l'instruction d'une manière commode (sans l'avoir téléchargée sur votre ordinateur) vous pouvez utiliser le mode d'exploration en plein écran. Pour démarrer l'exploration de l'instruction Bally Refrigerated Boxes s/Freezers/Warmers en plein écran, utilisez le bouton Plein écran.
  • Téléchargement sur l'ordinateur - vous pouvez aussi télécharger l'instruction Bally Refrigerated Boxes s/Freezers/Warmers sur votre ordinateur et la sauvegarder dans vos ressources. Si vous n'avez pas envie de gaspiller votre espace disque, vous pouvez toujours télécharger cette instruction du ManualsBase dans l'avenir.
Bally Refrigerated Boxes s/Freezers/Warmers Manuel d'utilisation - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Version imprimée

Beaucoup de gens préfèrent de lire les documents dans la version imprimée et non pas sur l'écran. L'option d'impression de l'instruction est aussi prévue et vous pouvez en profiter en cliquant le lien ci-dessus - Imprimez l'instruction. Il n'est pas nécessaire d'imprimer toute l'instruction Bally Refrigerated Boxes s/Freezers/Warmers - on peut choisir des pages. Economisez le papier.

Résumés

Vous trouverez ci-dessous les annonces des contenus qui se trouvent sur les pages suivantes de l'instruction de Bally Refrigerated Boxes s/Freezers/Warmers. Si vous voulez parcourir rapidement le contenu des pages suivantes de l'instruction, vous pouvez en profiter.

Résumés du contenu
Résumé du contenu de la page N° 1











Operation, Installation and
Instruction Manual
for
Reach-In and Roll-In
Refrigerators, Freezers and Warmers













BMIL International, Inc.
A Division of BALMAC International, Inc.
61 Broadway, Suite 1900 • New York, NY 10006-2701
212-898-9699 • Fax: 212-514-9234 - bmil@bmil.com

Résumé du contenu de la page N° 2

Operators Manual Table of Contents Page RECEIVING YOUR NEW MODEL........................................................................1 GENERAL INFORMATION AND IMPORTANT OPERATING FACTS .................1 UNCRATING YOUR NEW MODEL ......................................................................2 INSTALLATION AND LOCATION.........................................................................2 CLEARANCES.................................................................

Résumé du contenu de la page N° 3

RECEIVING YOUR NEW MODEL Congratulations on your recent purchase of Bally refrigerator superior food equipment products! When your shipment arrives, please thoroughly examine the shipping crate for any punctures, dents, or signs of rough handling. It is in your best interest to partially remove or open the shipping container in order to examine the model for any concealed damages which may have occurred during shipment. If the model is damaged, it must be noted on the delivering carr

Résumé du contenu de la page N° 4

UNCRATING YOUR NEW MODEL The shipping container should remain on your model as protection against dents or scratches while transporting it to the actual set-up location. Remove the shipping container only at the last possible moment by following these simple steps: 1. Using a pry bar, pry off and remove crate end bottom staples. 2. Pry off and remove crate front and rear bottom staples. 3. Slide crate upward and remove it, being careful not to rub against cabinet. There are up to four (4)

Résumé du contenu de la page N° 5

Important Note: To assure sufficient air supply and circulation to the condensing unit, a minimum clearance of 12" above the grill and 3" on each side and back of the cabinet must be provided (see figure 1). If necessary, special venting or air supply ducts must be installed by the installer for this purpose. Do not at any time obstruct the grill area in front of the cabinet in any way, and never place or store anything on top of the cabinet machine compartment. These rules are essential f

Résumé du contenu de la page N° 6

INSTALLING LEGS AND LEVELING REACH-IN MODELS Your new reach-in model is supplied with adjustable type legs for leveling purposes. Each single and two section model has four leg mounting holes on its case bottom, and three section models have six leg mounting holes. Legs are packed in the accessory carton from which they must be removed and installed on the cabinet case bottom (see figure 2). In order to install the legs, carefully tip the cabinet rearward adding four (4) 2" wood blocks und

Résumé du contenu de la page N° 7

Important Note: It is extremely important that your new reach-in or roll-in model is perfectly level for proper operation. If it is not level, the following adverse conditions will become apparent: 1. The door(s) will not be properly aligned and consequently will not provide a good seal. Roll-in door wiper(s) may bind. 2. Your model will run excessively due to improper door seal(s). 3. An excessive amount of ice will accumulate inside the cabinet, around the door opening(s) and especially

Résumé du contenu de la page N° 8

INSTALLING CONDENSATE EVAPORATOR No floor drains or plumbing connections are required since all models use an automatic condensate water evaporating system. All designer line models utilize a unique hot gas condensate water evaporating system which is completely self- contained and no further assembly or maintenance is required (these models are recognized by their evaporator coil which is located out of the food zone in an insulated plug-box housing next to the condensing unit). All value

Résumé du contenu de la page N° 9

REMOVAL OF DOORS AND DOOR ADJUSTMENT During installation, it may become necessary to remove the cabinet doors to facilitate passage through narrow doorways or hallways. To remove a door, pry off all hinge covers using a sharp tool or knife (see figure 5). Swing the door to the open-door position (90 degrees) and carefully lift the door upward, removing the door from the hinge bodies. If it is necessary to remove the hinge bodies from the cabinet face, be extremely careful not to lose the l

Résumé du contenu de la page N° 10

REMOVAL OF GRILL To remove the grill, loosen all four (4) grill mounting screws located on the backside of the grill one or two turns. Simply lift grill up off of its mounting screws and out. To replace the grill, line up the grill mounting screws with the keyhole slots located on the cabinet body, push in on the grill and down. Important note: If the model is provided with a digital or dial thermometer, the front grill cannot be completely removed from the cabinet without first removing

Résumé du contenu de la page N° 11

START-UP PROCEDURE ELECTRICAL CONNECTIONS To insure proper operation, your new model must be connected to an individual circuit that can supply the full voltage as stated on the cabinet serial data plate. For correct voltage, power draw, and wire accommodations, check the data on the serial data plate located on the inner right wall of your new model. Verify that this information exactly matches the electrical characteristics at the installation location. An electrical wiring diagram, l

Résumé du contenu de la page N° 12

START-UP CHECKLIST After your model has been installed, leveled, cleaned, and electrically connected in accordance with this manual, please take the time before start-up to observe the following precautions to assure troublefree operation: 1. Check that all exposed refrigeration lines are free of severe dents or kinks. 2. Check the condenser fan and evaporator fans for freedom to rotate without any obstructions 3. Make sure that the cabinet is properly leveled (see "leveling" under ins

Résumé du contenu de la page N° 13

OPERATION All cabinets must be given sufficient time to reach normal operating temperature before placing any food inside. Refrigerators are designed to maintain an ideal cabinet temperature of 38`f to 40`f (3.3`c to 4.4`c) and approximately 2 hours of operation are required to reach this temperature. Standard freezers are designed to maintain an ideal cabinet temperature of -2`f to 0`f (-18.9`c to -17.8`c) and approximately 4 hours of operation are required to reach this temperature. Low

Résumé du contenu de la page N° 14

that many degrees by pressing directly on the mylar display towards the left bottom. Once calibration is complete return to normal temperature mode by pressing once again on the mylar display towards the right center. Now, recheck the calibration. Example: the digital display reads 45`f and the internal thermometer reads 40`f so, the digital display must be increased by 5`. Press the right center of the display twice and the number -1 is displayed (this is the point of origin and could ha

Résumé du contenu de la page N° 15

REFRIGERATOR SYSTEM AND ADJUSTMENT All self-contained value line and designer line refrigerators are designed and factory set to maintain an average cabinet temperature of 38`f. The temperature control is accessible from the top of the electrical console box located on the cabinet top behind the front grill (see figure 6). If an adjustment is necessary to maintain the above temperature range only, place a screwdriver into the thermostat slot and turn clockwise for a colder cabinet temperat

Résumé du contenu de la page N° 16

FREEZER SYSTEM AND ADJUSTMENT All self-contained value line and designer line standard freezers and low- temperature freezers are designed and factory set to maintain an average cabinet temperature of 0` f and -15`f respectively. All freezers are designed for the purpose of holding pre-frozen food and although they are capable of freezing small quantities of fresh food, they are not to be used as fast or blast freezers. Do not attempt to freeze bulk quantities of fresh foods. The temperatur

Résumé du contenu de la page N° 17

After defrost, the fan delay control prevents the evaporator fans from operating until the evaporator coil has reached a temperature of 32°f (approximately 20 minutes) thus, minimizing warm air circulation inside the cabinet. Therefore, during initial start-up, and after each defrost cycle, the fans will not turn on immediately. FIGURE 8 DEFROST TIMER SETTING WARMER SYSTEM AND ADJUSTMENT All designer line warming cabinets are designed with an operatin

Résumé du contenu de la page N° 18

EVAPORATOR ASSEMBLY All value line and designer line refrigerators and freezers have an easily accessible, easily serviceable, performance rated, forced-air evaporator assembly which utilizes a plasticized fin coil for extended life. There are two different types of evaporator assembly systems used throughout the value line and designer line models as shown in figures 9 and 10: LOW-PROFILE,CEILING-MOUNT EVAPORATOR ASSEMBLY The low-profile evaporator system is comprised of a generous siz

Résumé du contenu de la page N° 19

PLUG-TYPE,TOP-MOUNT EVAPORATOR ASSEMBLY The plug-type evaporator system is a unique system in which the evaporator coil and air circulating fans are contained within a concealed plug-type insulated housing, readily accessible on the top of the cabinet and separate from the food storage zone. The entire plug system is fully charged with refrigerant and mounted on a steel rail type base which can be easily removed from the cabinet if a field conversion (refrigerator to freezer or vice versa)

Résumé du contenu de la page N° 20

INTERIOR REACH-IN ACCESSORIES The standard interior accessory package that is supplied from the factory with your new value line and designer line reach-in consists of standard pilaster strips with pilaster clips (four (4)clips per shelf), three (3) epoxy coated shelves per section, and four (4) epoxy coated shelves per section on glass door models only. SHELVING INSTALLATION Pilaster strips which support the shelving are secured to the cabinet walls with special pilaster screws which a


Instructions pareilles
# Instruction d'utilisation Catégorie Téléchargez
1 2JANE Surround Sound System HTS-GS1 Manuel d'utilisation Refrigérateur 4
2 3Com Phaser 7750 Manuel d'utilisation Refrigérateur 1
3 3Com iQ 10 Manuel d'utilisation Refrigérateur 0
4 3Com PowerDual iQ 10 iQ 10C Manuel d'utilisation Refrigérateur 1
5 3Com PowerDual iQ 10 iQ 10P Manuel d'utilisation Refrigérateur 2
6 3Com Dell D-Family Battery Charger CHRG01L Manuel d'utilisation Refrigérateur 0
7 3Com PowerDual iQ 10 iQ 10PC Manuel d'utilisation Refrigérateur 0
8 3Com Preface Firmware Version 1.07 VFD-D D Manuel d'utilisation Refrigérateur 0
9 3D Connexion Infinity Systems Interlude IL120s Manuel d'utilisation Refrigérateur 1
10 3D Connexion Cisco Catalyst Blade Switch 3040 for FSC Hardware OL-10694-01 Manuel d'utilisation Refrigérateur 0
11 3D Connexion 42" SNOW THROWER LST42B Manuel d'utilisation Refrigérateur 0
12 3D Connexion Cisco SCA BB SNMP Real Time Monitoring OL-12491-01 Manuel d'utilisation Refrigérateur 0
13 3D Connexion Primergy ServerView Suite TivoII Manuel d'utilisation Refrigérateur 0
14 3D Innovations The Xerox DocuPrint Color Laser Printer NC60 Manuel d'utilisation Refrigérateur 0
15 3G Green Green Globe Automatic Transfer Switch ZTS Series Manuel d'utilisation Refrigérateur 0