                        Q5RF SERIES 15 SEER
USER’s MANUAL & INSTALLATION INSTRUCTIONS
Single Package Heat Pump - 2 Stage, R-410A
IMPORTANT
Please read this information thoroughly and become familiar with the capabilities 
and use of your appliance before attempting to operate or maintain this unit. 
Keep this literature where you have easy access to it in the future. If a problem 
occurs, check the instructions and follow recommendations given. If these 
suggestions don’t eliminate your problem, call your Servicing Con
                    
                    Résumé du contenu de la page N° 2 
                    
                         Forced Defrost Mode (Field Test) .............12 USER INFORMATION  Anti Short Cycle Timer Test ......................12 About the Heat Pump ...................................3  Heating Mode ........................................12  Cooling Mode .........................................13  Operating Instructions ................................ 3  Cooling Operation ....................................3 Adjustment of Refrigerant Charge ............13  Heating Operation ........................
                    
                    Résumé du contenu de la page N° 3 
                    
                        USER INFORMATION ABOUT THE HEAT PUMP minutes following a previous operation or the  interruption of the main electrical power. Your heat pump is a unique, all weather comfort- control appliance that will heat and cool your  Emergency Heat home year round and provide energy saving  Some thermostats may include a system mode  comfort. It’s an unknown fact that heat is always  called EM HT or AUX HT, etc. This is a back- in the air, even when the outside temperature is  up heating mode that should 
                    
                    Résumé du contenu de la page N° 4 
                    
                        INSTALLER INFORMATION GENERAL INFORMATION SAFETY INFORMATION Single packaged heat pumps are ready for easy  and immediate installation and can be readily  connected into the high static duct system of a   WARNING: home. This unit is completely assembled, wired,  The information listed below  and run tested at the factory. This heat pump  is designed for outdoor installation only. The  must be followed during the  only connections needed for installation are the  installation, service, and operat
                    
                    Résumé du contenu de la page N° 5 
                    
                        Air Duct System Air ducts must be installed in accordance with  the standards of the National Fire Protection  Elbow Association “Standard for Installation of Air  Conditioning and Ventilation Systems” (NFPA  90A), “Standard for Installation of Residence Type  Warm Air Heating and Air Conditioning Systems”  (NFPA 90B), these instructions, and all applicable  codes. NFPA publications are avaialable by  writing to: National Fire Protection Association,  P-Trap Batterymarch Park, Quincy, ME 02269 o
                    
                    Résumé du contenu de la page N° 6 
                    
                        14” Duct Dimples Transition Duct Screws 12" 24" 12" 0" Supply Air Return Air Figure 3. Minimum Unit Clearances Figure 4. Return and Supply Air Fittings Installing Return & Supply Air Fittings The supply and return fi ttings are included with  2. Overlap the collar ends keeping the small  the unit and located in the supply duct. They  screw holes underneath. attach to the unit openings (Figure 4) with a fl ange  3. Align the holes in the crimped area and install  and bead arrangement and may be, se
                    
                    Résumé du contenu de la page N° 7 
                    
                        NOTE: The return air box with grille and fi lter Locating & Installing the Supply Damper(s) (Figure 6) should not be located in heavy traffi c  When locating the supply damper(s), carefully  areas like hallways or center of rooms. A good  check fl oor joists and frame members that could  spot is in a corner or under a table, if a minimum  interfere with the installation of the damper or  two inch clearance is available. fl exible duct. Ideally, the damper (Figure 7) should  be located in the bottom 
                    
                    Résumé du contenu de la page N° 8 
                    
                        ELECTRICAL CONNECTIONS � See the unit wiring label for proper high and low  voltage wiring. Make all electrical connections  in accordance with all applicable codes and   WARNING: ordinances. To avoid electric shock, personal  injury, or death, turn off the electric   CAUTION: power at the disconnect or the main  Label all wires prior to  service panel before making any  disconnection when servicing  electrical connections. controls. Wiring errors can  � Electrical connections must be in  cause 
                    
                    Résumé du contenu de la page N° 9 
                    
                        Overcurrent Protection Overcurrent protection must be provided at the   CAUTION: branch circuit distribution panel and sized as  shown on the unit rating label and according to  To avoid personal injury or  applicable local codes. Generally, the best fuse  property damage, make certain  or breaker for any heat pump is the smallest  that the motor leads cannot  size that will permit the equipment to run under  normal usage and provide maximum equipment  come into contact with any metal  protectio
                    
                    Résumé du contenu de la page N° 10 
                    
                        Demand Defrost Control Electric Heat Package (optional) The demand defrost board controls the defrost This heat pump is shipped without an auxiliary  cycle in response to ambient temperature,  electric heat kit installed. If electric heat is desired,  outdoor coil temperature and accumulated an accessory Heater Kit must be fi eld installed.  compressor run time. The heat pump is allowed to See Specifi cations Sheet for available kits and  operate in the heating mode until the combination their app
                    
                    Résumé du contenu de la page N° 11 
                    
                        COND FAN COND FAN AMBIENT AMBIENT M AMBIENT AMBIENT M SENSOR AMBG SENSOR PRESS AMBG DEMAND PRESS DEMAND COILG DEFROST CONTROL COIL COILG DEFROST CONTROL COIL SW BOARD SENSOR SW COIL BOARD SENSOR COIL REV REV TEST W2 W2 TEST W2 W2 LR C Y O IN OUT LR C Y O IN OUT VALVE VALVE Outdoor Thermostat Y1 = 1st Stage Heat Pump (optional) Y2 = 2nd Stage Heat Pump W1 = 1st Stage Auxillary Heat Green (from blower relay) G W1 R Accessory C Heat Plug Y1 1 Brown O 2 Orange 3 E 4 Y2 5 6 Blower Relay 7 Compressor 
                    
                    Résumé du contenu de la page N° 12 
                    
                        STARTUP & ADJUSTMENTS temperature selector below the existing room  temperature. Allow the cooling system to operate  Pre-Start Checklist for several minutes and check for the discharge  The following check list should be observed prior  of cool air at the supply registers. to starting the unit.  Is the unit level? Unit should be level or slightly  Short Cycle Protection slanted toward the drain for proper condensate  The control circuit is equipped with a time-delay  drainage.  feature for pro
                    
                    Résumé du contenu de la page N° 13 
                    
                        Cooling Mode Charging an R-410A Unit in Heating Mode When the TEST pins are shorted together for  1. Evacuate the refrigerant system. more than 1 second, the Anti Short Cycle Timer  2.  Weigh in the proper charge as shown on the  will be bypassed. unit rating plate and use the Heating Charging  Tables 2 & 3 (pages 16 & 17) as a guide. Tables  Adjustment of Refrigerant Charge refl ect conditions at high speed operation. Unit  charge MUST be verifi ed in cooling season. 3.  Verify the unit is operat
                    
                    Résumé du contenu de la page N° 14 
                    
                        Refrigerant Charging Charts for Cooling Mode of Operation Q5RF-X24K CHARGING CHART 600 575 550 525 500 Remove refrigerant when above curve 475 450 425 400 375 350 325 Add refrigerant when below curve 300 275 250 225 200 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 LIQUID TEMPERATURE (F) Figure 11. Charging Chart for 2 ton Units Q5RF-X36K CHARGING CHART 600 575 550 525 500 Remove refrigerant when above curve 475 450 425 400 375 350 325 Add refrigerant when below curve 300 275 250 225 200
                    
                    Résumé du contenu de la page N° 15 
                    
                        Refrigerant Charging Charts for Cooling Mode of Operation - Continued Q5RF-X48K CHARGING CHART 600 575 550 525 500 Remove refrigerant when above curve 475 450 425 400 375 350 325 Add refrigerant when below curve 300 275 250 225 200 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 LIQUID TEMPERATURE (F) Figure 13. Charging Chart for 4 ton Units Q5RF-X60K COOLING CHARGING CHART 600 575 550 525 500 Remove refrigerant when above curve 475 450 425 400 375 350 325 Add refrigerant when below curve
                    
                    Résumé du contenu de la page N° 16 
                    
                        16 Refrigerant Charging Chart Legend for Heating Mode of Operation:  Shaded boxes indicate fl ooded conditions.  Rated design values. The suction pressure will vary from design value if outdoor air fl ow, entering dry bulb, or entering wet bulb temperatures  vary. 1. All pressures are listed psig and all temperatures in °F 2. Discharge temperatures greater than charted values indicate an undercharged system. Q5RF-X24K OUTDOOR TEMPERATURE (DEG. F) 0 102030405060 Suc. Liquid Disch. Suc. Liquid Disch
                    
                    Résumé du contenu de la page N° 17 
                    
                        17 Refrigerant Charging Chart Legend for Heating Mode of Operation:  Shaded boxes indicate fl ooded conditions.  Rated design values. The suction pressure will vary from design value if outdoor air fl ow, entering dry bulb, or entering wet bulb temperatures  vary. 1. All pressures are listed psig and all temperatures in °F 2. Discharge temperatures greater than charted values indicate an undercharged system. Q5RF-X48K OUTDOOR TEMPERATURE (DEG. F) 0 102030405060 Suc. Liquid Disch. Suc. Liquid Disch
                    
                    Résumé du contenu de la page N° 18 
                    
                        Figure 15. Q5RF/PPH2RF Series Wiring Diagram - 2 & 3 Ton Units 18 3. Not sutiable on systems that exceed 150V to ground. WIRING DIAGRAM 4. For replacement wires use conductors suitable for 105°C. Q5RF/PPH2RF SERIES SMALL PACKAGE H/P W/DEMAND DEFROST 208/230V 60HZ/SINGLE PHASE 2 TON AND 3 TON 1. Couper le courant avant de faire letretine. NOTES: 2. Employez uniquement des conducteurs en cuiver. 1. Disconnect all power before servicing. SEE TABLE FOR FACTORY  3. Ne convient pas aux installations d
                    
                    Résumé du contenu de la page N° 19 
                    
                        Figure 16. Q5RF/PPH2RF Series Wiring Diagram - 4 & 5 Ton Units 19 WIRING DIAGRAM 60HZ/SINGLE PHASE Q5RF/PPH2RF SERIES SMALL PACKAGE H/P W/DEMAND DEFROST 208/230V 4 TON AND 5 TON 1. Couper le courant avant de faire letretine. NOTES: 2. Employez uniquement des conducteurs en cuiver. 1. Disconnect all power before servicing. 3. Ne convient pas aux installations de plus de 150V a la terre. SEE TABLE FOR FACTORY 2. For supply connections use copper conductors only. SET BLOWER WIRING 3. Not sutiable o
                    
                    Résumé du contenu de la page N° 20 
                    
                        COMPONENT FUNCTIONS High Pressure Switch The high pressure switch is factory installed  Low Pressure Switch and located in the compressor discharge line  The low pressure switch is factory installed and  internal to the unit. The switch is designed to de- located in the suction line internal to the unit. The  energize the system when very high pressures  switch is designed to protect the compressor if a  occur during abnormal conditions. Under normal  loss of charge occurs. Under normal conditio