ページ1に含まれる内容の要旨
Keypad Arming Station ELK-M1KPAS
APPLICATION
The ELK-M1KPAS is an easy to use, slim line keypad for use in arming
and disarming any of the M1 Family Cross Platform Controls. It fits into
a single gang electrical box and utilizes any standard decorator style
faceplate. It handles basic functionality and displays system status
using 3 LEDs: Green for "Ready", Yellow for "Trouble", and Red for
"Armed". The low cost and small footprint of the M1KPAS Arming
Station makes it ideal for use as an alt
ページ2に含まれる内容の要旨
INSTALLATION OF ELK-M1KPAS KEYPAD ARMING STATION The M1KPAS mounts into a standard electrical box. Depending upon local/state regulations it may be permissible to mount an M1KAS alongside other electrical devices provided that a special low voltage divider insert and/or low voltage combo box is utlized. Select a location ° ° ° with an ambient temperature range between 32 and 120 F (0° to +49 C). Avoid direct sunlight if possible. CAT5 or CAT6 wire (4 pair, 8 conductor) is highly recommended
ページ3に含まれる内容の要旨
Address and Enrollment Keypads and expander devices that operate on the RS-485 4-wire data bus must each have a unique address setting from 1 to 16 within their device TYPE. Keypads are device TYPE 1, input (zone) expanders are TYPE 2, output expanders are TYPE 3, etc. The purpose of device types is so that the address numbers can be re-used in each different device type. It is OK to have a Keypad, a Zone Expander, and a Output Expander all set to address 2 on the same data bus since each dev
ページ4に含まれる内容の要旨
Troubleshooting and Diagnostics Symptom Potential Cause Remedy (Things to try) No visual or audible feedback Keypad is not communicating with the Check wiring and plug connections. Verify power at when buttons are pressed. control. Power may be off or wiring connections using a voltmeter. unplugged. Ready, Trouble, Armed, Stay, and Keypad is communicating but it has not Use the bus module enrollment procedure to enroll the Exit LEDs are lighting in a been enrolled with the Control. keypad into
ページ5に含まれる内容の要旨
(Inside Fold Line) Using the Quick Arm Arming in the Away Mode Away mode arming is the highest arm level, intended for use when the premises is unoccupied. Both (Optional) If this feature was enabled by your installer, it will allow arming in either the perimeter and interior zones will be armed. The Ready light must be on or flashing for the alarm system to be Away or Stay modes without having to enter your user code. For security reasons however, a armed. user code is always required to
ページ6に含まれる内容の要旨
SYSTEM NOTES ARMING STATION OPERATION GUIDE Central Monitoring Station: _______________________________ Acct. # ______ Ready Light - Light is ON when all burglar zones are secure and the Installation Company: ________________________________________________ system is OK for arming. If this light is OFF, one or more zones are violated (not secure) and the system cannot be armed. If light is FLASHING it indicates that the system may be "Force Armed". Force Address: ____________________________