ページ1に含まれる内容の要旨
RC300
IntelliFire Plus™ Multifunction Remote Control
Installation & Operating Instructions
FCC Requirements
Hearth & Home Technologies disclaims any responsibility for,
WARNING! Risk of Fire! Changes or modifi cations to
and the warranty will be voided by, the following actions:
this unit not expressly approved by the party responsible
• Installation and use of any damaged system component.
for compliance could void the user’s authority to operate
• Modifi cation of the system component.
the
ページ2に含まれる内容の要旨
4. Place remote control inside housing. See Figure 3. Changing Temperature Scale To change the temperature display between Celsius and Fahrenheit, remove the battery cover from the back of the remote control and slide the switch to your desired tem- perature scale (see Figure 1). The screen will automati- cally change the indicators on the room temperature and set temperature portion. Figure 3. Remote in Housing 5. Close the housing door. See Figure 4. Figure 1. Temperature scale Inst
ページ3に含まれる内容の要旨
Fan Installation • Insert the 3 prong plug from the fan into the receptacle located in the AUX300 module. See Figure 6. REMOTE POSITION REMOTE POSITION • Insert 3 prong plug from AUX300 module into REM/AUX receptacle of fi replace junction box. A AUX 300 MODULE UX 300 MODULE Figure 7. Programming RC300 F FA AN CORD N CORD Figure 6. Plug Fan into AUX300 Module Programming the RC300 to the Control Module CAUTION! Risk of burns! DO NOT program the remote control to the control module when fi re
ページ4に含まれる内容の要旨
RC300 4.5V DC (AAA X 3) FLAME IGNITER SENSE TO JUNCTION 6V DC BOX (120V) SUPPLY 3 PRONG 120VAC CONTROL MODULE I AUX300 MODULE S FAN FLAME AUX 1 AUX 2 TO JUNCTION MODULATION BOX 120VAC BATTERY PACK TO OPTIONAL 6V DC COMPONENTS RED ORANGE GREEN BLACK (PILOT) (MAIN) BROWN BROWN/RED OPTIONAL ON/OFF SWITCH GROUND Figure 8. RC300 Wiring Diagram 4 Hearth & Home Technologies • RC300 Multifunction Remote Control • 2166-393 Rev. C • 9/10 WHITE ORANGE
ページ5に含まれる内容の要旨
Display Screen Idle When Remote is in ON Mode The remote control will go into an idle mode if no but- THERMOSTAT DESIRED FIREPLACE STATUS tons are pressed within 5 seconds. Press any button to TEMP SETTING resume full functionality. In idle mode only active func- tions will show on the screen. THERMOSTAT CHILD LOCK FLAME HEIGHT INDICATOR FAN SPEED TRANSMISSION INDICATOR ADJUSTABLE AUXILIARY LOW BATTERY ADJUSTABLE INDICATOR OUTPUT (ON/OFF) CONSTANT PILOT FUNCTION LEVEL INDICATOR ROOM TEMP
ページ6に含まれる内容の要旨
About ON Mode Adjusting Fan Speed • All functions can be accessed when the remote control • Press the MENU button to activate the menu. is in the ON mode. • Using the UP and DOWN arrows highlight the FAN icon • Only active functions will be displayed when the remote and press SELECT. control is in the ON mode. For example: if the fan is the • Use the UP and DOWN arrows to adjust the FAN SPEED, only function that’s active, the fan icon and fl ame will be then press SELECT. The FAN SPEED can b
ページ7に含まれる内容の要旨
Adjusting Thermostat Power Outage • Press the MENU button to activate the menu. • If fi replace battery backup system IS installed at time of power outage, fi replace operation will not be interrupted. • Using the UP and DOWN arrows highlight the THERMO icon and press SELECT. • If fi replace battery backup system IS NOT installed at time of power outage, fi replace will shut off. To resume • Use the UP and DOWN arrows to turn the THERMO ON fi replace operation, install battery backup. or OFF, t
ページ8に含まれる内容の要旨
Frequently Asked Questions/Troubleshooting Symptom Possible Cause Corrective Action Batteries Verify batteries are functional and installed correctly. Remote control is in Child Disengage Child Lock mode. Remote control will not transmit Lock mode Buttons not being pressed Press button fi rmly for one to two seconds to ensure transmis- fi rmly sion to module. Control module is not in Ensure module switch is set to REMOTE. “REMOTE” mode Control module and remote The control module will beep when