                        0311   A  OI
GT-2C-L/GT-2C
	
GT-2H-L/GT-2H
Apartment Intercom System
Master Monitor Station/Sub Master Monitor Station
GT-2C-L/GT-2C
Master monitor station
GT-2H-L/GT-2H
Sub master monitor station
OPERATION MANUAL                                                                                                                                                                                                                                                                                  
                    
                    ページ2に含まれる内容の要旨 
                    
                        PRECAUTIONS  General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions WARNING General Precautions 1. Keep the unit more than 1 m away from radio or TV set. (Negligence could result in death or serious injury.) 2. This unit is for indoor use only. Do not use outdoors.  1. High voltage is present internally. Do not open the case. Electric shock could result. 3. In areas where broadcasting station antennas are close by, intercom system m
                    
                    ページ3に含まれる内容の要旨 
                    
                                                                                                                                                                                                                                                                                                            - 3 -                                                                                                                                                                                                                           
                    
                    ページ4に含まれる内容の要旨 
                    
                        NAMES  1  Master monitor station (GT-2C-L/GT-2C) Screen brightness control Color LCD video   0  10  monitor Speaker Adjust the LCD screen brightness. Hearing aid T-mode  *1 compatibility symbol (GT-2C-L only) Receive volume control *5 MENU button  0  10  CALL button ADJUST button Adjust the receive volume during  MONITOR button ZOOM/WIDE  communication. REC/PLAY button button At "0", no sound is output. PAN/TILT button  Call tone volume Indicated with  STATUS LED (orange) *2  0  10       TON
                    
                    ページ5に含まれる内容の要旨 
                    
                        VIEWING THE SCREEN (MASTER MONITOR STATION)  2  Displays during recording or playing  Recording  Play Door release operations are indicated. (This does not exactly  correspond to the door release status of the entrance station.) The status is displayed. "CALLING ENTRANCE1": When there is a call from entrance 1 "IN-USE ENTRANCE1": During communication with entrance 1 Displays while screen is being adjusted. CALLING ENTRANCE1 MAY/26 18:45  Backlight adjustment 1, Backlight adjustment 2  Night adju
                    
                    ページ6に含まれる内容の要旨 
                    
                        3-1 Turning off the screen display  is displayed on the screen while video images are played. Press    
 
 the [ MENU] button to turn off all items displayed on the screen  (date, time, etc.) so that the entire picture is visible. 3-2 Setting the date and time 1 In the standby mode, press the [ MENU] button. 3 In the "DATE/TIME" screen, press the [] or [] button to select the  • When the time is set to the initial setting, skip step 2 and go to step 3. "Month". 2 Press 
                    
                    ページ7に含まれる内容の要旨 
                    
                        RECEIVING CALLS  4  The unit used in the example pictures is a master monitor station. 4-1 Answering a call 1 When a call is received from an entrance station, security guard sta- 3 When you are done talking, press the [ OFF] button. tion, or door station, a call tone will sound and the STATUS LED   The STATUS LED will go off. blinks. If the station has a camera, a picture will be displayed on the  monitor. If the station has a doorbell, a call tone sounds. (Communica- tion is not possible.) 2 P
                    
                    ページ8に含まれる内容の要旨 
                    
                        4-2 Door release 1 Press the [ ] button while in communication with the entrance sta- 2 Door release is activated at the entrance station.  is displayed  tion. for approx. 5 sec. at the master monitor station. (This does not exactly  correspond to the door release status of the entrance station.) • If the station has a camera, the door release will also activate during calling. Depending on the electric door release system that you use, door re- lease may be active only while the door release bu
                    
                    ページ9に含まれる内容の要旨 
                    
                        CALLING  5  The unit used in the example pictures is a master monitor station. 5-1 Calling security guard stations 2 Move the cursor to the security guard station to be called and press the  1 When calling all of the security guard stations, press the [ GUARD]  [ MENU] button. The STATUS LED blinks and calls the indicated  button while in the standby mode. security guard station. 1 When calling one of the security guard stations, press the [ MENU]  • If there is no answer, a call record will be 
                    
                    ページ10に含まれる内容の要旨 
                    
                        MONITORING  6  The unit used in the example pictures is a master monitor station. 1 In the standby mode, press the [ MONITOR] button to display the  NOTES: 1. If there is an operation such as a call, monitoring ends and the call   video image from an individual door station. Audio can heard at the  operation begins. same time. The STATUS LED will light up. 2. If the monitor b utton of a residential station at another residence is  pressed, monitoring of the entrance station switches to the monit
                    
                    ページ11に含まれる内容の要旨 
                    
                        OPERATION DURING COMMUNICATION AND MONITORING  7  The unit used in the example pictures is a master monitor station. 7-1 ZOOM/WIDE switching 1 Press the [ ZOOM/WIDE] button when a picture is displayed. • Switching between zoom  wide occurs each time the button is pressed. [Wide picture] [Zoom picture] NOTES: 1. When the caller is not sho wn in the center of the picture, the zoom  picture can be moved up, down, left, and right. (Refer to section 7-2.)  2.  For an individual door, when the display
                    
                    ページ12に含まれる内容の要旨 
                    
                        7-4 Night illumination At night, the illuminator LED lights up during an entrance station or indi- vidual door station call. Also, the LED can be made to light up during  monitoring of a individual door station. When a call is made from an entrance station or individual door Lighting up the illuminator LED when monitoring an individual door  station station 1 When the [ TALK] button is pressed during monitoring, com- 1 If the call button of the entrance station or individual door station is  mun
                    
                    ページ13に含まれる内容の要旨 
                    
                        RECORDING AND PLAYING (MASTER MONITOR STATION)  8  8-1 Automatic recording If call is received from an entrance station or individual door station, re- Zoom pictures (from 1st shot to 6th shot) cording starts automatically. During recording, the  symbol blinks on  1st shot the screen. 2nd shot • Recording starts approximately 2 seconds after the CALL button of an entrance  station or individual door station is pressed. A maximum length of approximate- ly 6 seconds (6 shots) can be recorded, with
                    
                    ページ14に含まれる内容の要旨 
                    
                        8-3 Playing recorded pictures If there are automatically recorded pictures, such as those taken while you  were out, the STATUS LED blinks with a long interval during standby  mode. * In addition, the operations shown below are also possible in the play-waiting  screen. • [ MONITOR] button:  To display the next (more recent date/time) picture.  When the button is pressed for 1 second or more, the first picture of the set  will display and then the other pictures can be checked in succession in th
                    
                    ページ15に含まれる内容の要旨 
                    
                        8-4 Saving recorded pictures 10 images can be saved from the recorded images (maximum of 40 images). 2 Press the [ MONITOR] button. Saved pictures are not overwritten.     1 Display the picture that you want to save in the play-waiting screen.  (Refer to section 8-3.)  Press the [ MENU] button to display the save/erase selection screen.     3  is displayed when saving is performed. If the picture has already  been saved, the save is canceled.  Each time the [ MONITOR] button is pressed, the oper
                    
                    ページ16に含まれる内容の要旨 
                    
                        ALARMS AND RELATED INFO.  9  The unit used in the example pictures is a master monitor station. 9-1 OPTION button Pressing the [ OPTION] button allows for operation of connected units  to be performed such as turning lights on and off. 9-2 Emergency alarm 4 Press the [ TALK] button to communicate with the security guard  1 Press and lock the emergency alarm switch (or when there is a line -  station. The STATUS LED will light up. After communication, the  off trouble). emergency alarm will begin
                    
                    ページ17に含まれる内容の要旨 
                    
                        9-3 External calls 1 When a separately-installed sensor is activated or the CALL button is 2 Press the [ OFF] button or [ REC/PLAY] button ([ OFF] but- pressed, the alarm sounds, and the warning screen displays on the  ton for GT-2H-L/GT-2H) to stop the alarm sound. monitor and blinks. • Only the alarm sounds at sub master monitor stations.  
$%  NOTES: 1.  The alarm sound time is set in the external settings. (Refer to sec- tion 10-5.)   The initial setting is 10 minute.  2. 
                    
                    ページ18に含まれる内容の要旨 
                    
                        9-5 Canceling security setting after arrival (master monitor station) 1 When the ABSENCE SECURITY setting in 9-4 is set, if an individu- 3 Restoration occurs when the security PIN is correct. al door is opened, a screen will display and the alarm will sound. • If the security PIN is not correct, "WRONG SECURITY PIN." will display. • There is no limit to the number of times the PIN can be entered, but if a cor- • At this time, operation other than an emergency alarm cannot be performed.  rect sec
                    
                    ページ19に含まれる内容の要旨 
                    
                         CHANGING SETTINGS (MASTER MONITOR STATION)  10 The screen may vary depending on the equipment being used. 10-1 Using the MENU 1 In the standby mode, press the [ MENU] button. 3 Press the [], [], [], and [] buttons in the "SETTINGS" screen  to select the item to be confirmed, and press the [ MENU] button. 2 Press the [] or [] button to select "SETTINGS", and press the  [ MENU] button.         "        
                    
                    ページ20に含まれる内容の要旨 
                    
                        10-3 CALL TONE switching Separate sounds can be selected for entrance stations, individual door sta- 3 In the separate "CALL TONE" screens for "ENTRANCE/DOOR/ tions, and security guard stations from 5 sound types. GUARD", select the desired call tones. The selected call tone sounds,  enabling you to check the sound. Press the [ MENU] button to  1 After performing steps 1 and 2 in section 10-1, select "CALL TONE"  complete the settings. in the "SETTINGS" screen and press the [ MENU] button. • The