ページ1に含まれる内容の要旨
SAM-V8M 8-Port Voice Module
User Guide
1001 East Hwy 212 Toll Free: 1-800-852-8662
Hector, MN 55342 Local: 1-320-848-6711
www.suttlesoho.com Fax: 320-848-2361
ページ2に含まれる内容の要旨
1. Introduction Features • Conforms to UL standards. • Accommodates up to 4 telephone service lines. • Alarm interface is configured for use on service line 1. • Centralized test port, to verify incoming phone service. • Supports up to 8 home run terminations. • Installer-friendly push-lock pin mounting. Package Contents • 8 Port Voice Module • 3” Jumper Cord (do not discard) 3” Jumper • User Guide Cord User Guide 8-Port Voice Module Compare the c
ページ3に含まれる内容の要旨
2. Module Installation Mounting: Align the mounting pins with the grid holes on the back of the enclosure. With the mounting pin plungers in the “out” position, press the unit into the grid in the desired location, secure by pushing the plungers in. Terminate Incoming Service Lines: Run twisted pair cable from the telephone company demarcation point to the 110 IDC labeled “LINE IN” on the SAM-V8M. 110 IDC Termination Procedure Strip 3 in. of outer jacket from the cable. Place
ページ4に含まれる内容の要旨
Terminate Premise Wiring: Direct Distribution Run twisted pair cable from the telephone jacks throughout the premise to the numbered distribution jacks. Terminate modular 8 position plugs to the horizontal cables using the 568A wire standard. Patch Panel Distribution Run twisted pair cable from the telephone jacks throughout the premise to the 110 IDCs of a SAM-D8 patch panel using the termination procedure above. Connect the numbered distribution ports of the SAM-V8M to the desi
ページ5に含まれる内容の要旨
Wiring Diagram:
ページ6に含まれる内容の要旨
3. Testing Test Incoming Service Lines: To test the incoming service lines, disconnect the jumper cord from the “TEST” jack, which will deactivate the “OUT” jack and all distribution ports. Plug the tester into “TEST” jack to verify phone service. Reconnect the jumper cord between the “TEST” jack and “OUT” jack to restore service to the distribution ports. Test Distribution Cabling: To test the distribution cabling, disconnect the jumper cord from the “OUT” jack, which will deacti
ページ7に含まれる内容の要旨
Important Information: • Read and understand all instructions. Follow all warnings and instructions marked on the product. • Do not use this product near water,--e.g., near a bath tub, wash basin, kitchen sink, wet basement, or near a swimming pool. • Never push objects of any kind into this product through openings, as they may contact dangerous voltages. • SAVE THESE INSTRUCTIONS. Safety Information: • Never install communications wiring or components during a lightning storm. • N
ページ8に含まれる内容の要旨
100970-00 Rev..A 1001 East Hwy 212 Toll Free: 1-800-852-8662 Hector, MN 55342 Local: 1-320-848-6711 www.suttlesoho.com Fax: 320-848-2361