                        IMPORTANT FOR YOUR SAFETY    THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO  INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD  START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS  MANUAL.    POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN  THE EVENT THE SMELL OF GAS IS DETECTED.  THIS INFORMATION CAN BE  OBTAINED FROM THE LOCAL GAS SUPPLIER.        IMPORTANT  IN THE EVENT A GAS ODOR IS DETECTED, SHUT  DOWN UNITS AT MAIN SHUTOFF VALVE AND  CONTACT THE LO
                    
                    ページ3に含まれる内容の要旨 
                    
                        INSTALLATION, OPERATION AND CARE OF  GAS COUNTERTOP CHARBROILERS    GENERAL    Gas Countertop Charbroilers are designed for commercial use only and feature fast,  efficient gas heat.  Each burner is controlled by an adjustable gas valve. Cast radiants  are located directly above each burner to maintain uniform temperature. Radiants are  easily removed for cleaning when cool.    Heavy-duty, cast iron top grates are reversible to allow all or part of the cooking grid  surface to be level or sloped
                    
                    ページ4に含まれる内容の要旨 
                    
                        supply connection(s).  Provide 24" clearance at the front for cleaning, maintenance,  service and proper operation.    Minimum clearances to combustible construction are 12" to the back and 9" to the sides.  Minimum clearances to non-combustible walls are 3" to the rear and 3" to the sides.  INSTALLATION CODES AND STANDARDS  The Charbroiler must be installed in accordance with:  In the United States of America:  1. State and local codes.  2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest e
                    
                    ページ5に含まれる内容の要旨 
                    
                        Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting  the line to the unit.  Codes require that a gas shut-off valve be installed in the gas line ahead of the  charbroiler.  The gas supply line must be at least the equivalent of ¾” iron pipe.  72-inch  units should be connected to the gas supply on both the left and right sides to provide  adequate gas flow.    A pressure regulator is supplied and must be installed outside of the broiler when making  the gas
                    
                    ページ6に含まれる内容の要旨 
                    
                        CASTER EQUIPPED CHARBROILERS  Charbroilers mounted on stands with casters must use a flexible connector (not supplied)  that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69  • CSA 6.16 and a quick-disconnect device that complies with the Standard for Quick- Disconnect Devices for use With Gas Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate  means must be provided to limit movement of the broiler without depending on the  connector and the quick-disconnect dev
                    
                    ページ7に含まれる内容の要旨 
                    
                        The charbroiler is a free vented appliance.  All products of combustion and the heat  generated by the burners pass through the grates.  When meat is placed on the grates,  this blocks the venting and causes a temperature build-up.  The charbroiler operates most  1 efficiently with valves turned down to / or ½.  3   LIGHTING THE GAS PILOT (Fig. 3)  1.  Turn the individual burner gas valves  off and wait 5 minutes.  Pilot 2. Remove the Top Grates.  Turn the  incoming main gas supply valve on.   L
                    
                    ページ8に含まれる内容の要旨 
                    
                        MAINTENANCE  WARNING: THE CHARBROILER AND ITS PARTS ARE HOT.  USE CARE WHEN  OPERATING, CLEANING, OR SERVICING THE CHARBROILER.      VENT SYSTEM  At least twice a year the exhaust hood (venting system) should be examined and cleaned.      SERVICE  Contact your local Service Agency for any repairs or adjustments needed on this  equipment.    ACCESSORIES  STANDS  The charbroiler has an optional 24” high by 30” deep by 24”, 36”, 48”, 60” or 72” wide  stainless steel stand with casters or flanged le