ページ1に含まれる内容の要旨
I
i .......
+ , 1/4" Dim Conduit Access Hole* 1 1/4" Dia Conduit Access Hole*
5/8" Plywood Floor (Must Support 142 lbs) 5/8" Plywood Fioor (Must Support 142 lbs) ...........
__2 27" WALL OVEN DESCRIPTION 12 30" WALL OVEN DESCRIPTION ..........
DIMENSIONS DIMENSIONS
in cm in cm
A 27 MIN 68.58 MIN A 30 MIN 76.20 MIN ..............
B 24 MIN 60.96 MIN B 24 MIN 60.96 MIN
D 23 1/2 MIN 59.69 MIN D 23 1/2 MIN 59.69 MIN ..............
O 277/16±1/16 69.69 ±.16 C 277/16±1/16 69.69 ±.16
E 251/2±1/16 64.77 ±
ページ2に含まれる内容の要旨
i S ........................ ........................ i..... ' "Z i ........................... ............... • 1 1/4" Dia Conduit Access Hole--*-- 1 1 1/4" Dia Conduit Access Hole* 2 5/8" Plywood Floor (Must Support 250 Ibs) 2 5/8" Plywood Floor (Must Support 250 Ibs) DIMENSIONS DIMENSIONS ...... in cm in cm A 27 MIN 68.58 MIN A 30 MIN 76.20 MIN B 24 MIN 60.96 MIN B 24 MIN 60.96 MIN C 49 5/8 4-1/16 126.05 4-.16 C 49 5/84-1/16 126.05 ±.16 ..... D 23 1/2 MIN 59.69 MIN D 23 1/2 MIN 59,69 MIN ...
ページ3に含まれる内容の要旨
UNDERCOUNTER INSTALLATION .......................................... .... _ ...... i ................. ........................ i .......................... ! 27" WALL OVEN DESCRIPTION 30" WALL OVEN DESCRIPTION 1 1/4" Dia Conduit Access Hole* 1 1 1/4" Dia Conduit Access Hole* 5/8" Plywood Floor (Must Support 142 Ibs) 2 5/8" Plywood Ftoor (Must Support 142 [bs) - i ,,l DIMENSIONS DIMENSIONS _-. ..... ............ in cm in cm ............ 25 63.50 A 25 63.50 24 MIN 60.96 MIN B 24 MIN 60.96 MIN ...
ページ4に含まれる内容の要旨
ElectricalConnections Unit to be properlycircuit protected and wired accordingto local electrical code and National Electrical Code. It is advisable that the electrical wiring and hookuF C."'_ _ accomplished by a competent electrician. 120/240 VAC or 120/208 VAC 60 Hz. See serial plate on front of unit for power requirements. 1. Cut hole in cabinet to mount oven. Cutout in cabinet The neutral of this unit is grounded to the frame through the should be level and straight, green or solid grounding