ページ1に含まれる内容の要旨
Quiet-Vent
TS-174E
Owner’s Manual — Quiet-Vent Ventilation System
Installation, Operation & Service Instructions
Read and Save These Instructions
Quiet-Vent is a central exhaust ventilation system that replaces noisy, low output and
unreliable bath fans. With today’s tight homes, Quiet-Vent presents one of the best ways
to eliminate pollutants (i.e. normal household chemicals, outgasing from construction
materials, furniture and carpeting) by exhausting them out of the home. Quiet-Vent
a
ページ2に含まれる内容の要旨
Table of Contents 1 Specifications 1 Specifications ........................................................ Model: Quiet-Vent 2 Installation ............................................................ Electrical Specs: 0-0V ac, 60Hz, ph . Back-Drafting Open Combustion De vices ........... Max HACR Type Circuit Breaker or Fuse: 0A . Location of the Quiet-Vent ................................ Blower: Fasco 7090-806 0.65 Amps, Thermally Protected .3 Fresh Air Inlets ......
ページ3に含まれる内容の要旨
11” Hanger Strap (4 supplied) 6” Inlet 6” 4” Inlet Inlet 4” 4” Inlet Inlet 11” Hanger Strap (4 supplied) 6” Inlet 4” 6” Inlet Inlet 4” 4” Inlet Inlet be positioned in the home to minimize the amount of 14.5” duct and wire required for installation. The unit should 11” Hanger Strap be mounted and oriented to allow periodic blower oiling, (4 supplied) cleaning of the internal blower screen via the side mounted clean-out port, and adjustment of the 7-day timer (the timer can be remote mount
ページ4に含まれる内容の要旨
2.4 Hanging the Quiet-Vent Circuit to next timer in bath or kitchen The Quiet-Vent has four vibration absorbing straps for Timer switch Timer switch ground hanging from joists, rafters, or trusses (See Fig. & 3) ground and use (4) /4” diameter lag bolts or the equivalent. 115 Volt circuit/ground from Locate the unit to minimize the ducting from the baths and Quite-Vent to bath or kitchen kitchen to the Quiet-Vent inlets and from the Quiet-Vent outlet to the outside. Because the oiling
ページ5に含まれる内容の要旨
WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnect- ing means cannot be locked, securely fasten a prominent warning device, such as a tag, to
ページ6に含まれる内容の要旨
5.4 Fan Motor 5 Service If the blower motor fails to operate when voltage is present at its leads, the motor is defective and the blower must be replaced. CAUTION: Requires a qualified service person because electrical shock hazard is present. 5.5 Warranty The Quiet-Vent is guaranteed for two years from the date of 5.1 Circuit Breaker Trips installation against all manufacturing defects provided the Check For Short In Wiring: Quiet-Vent has been installed, operated, and maintained as state
ページ7に含まれる内容の要旨
QUIET-VENT Ventilating System Limited Warranty Warrantor: Therma-Stor LLC PO Box 8680 Madison, WI 53708 Telephone: -800-533-7533 Who Is Covered: This warranty extends only to the original residential end-user of the Quiet-Vent Ventilating System, and may not be assigned or transferred. Warranty: Therma-Stor LLC warrants that, for two () year s from the date of installation, the Quiet- Vent Ventilating System will operate free from any defects in materials and workmanship, provided the