ページ1に含まれる内容の要旨
Order No: PHAAM1111087C1
Indoor Unit Outdoor Unit
CS-E9NKUAW CU-E9NKUA
CS-E12NKUAW CU-E12NKUA
Please file and use this manual together with the service manual for Model No. CU-2E18NBU, Order No. PHAAM1111120A1.
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a pro
ページ2に含まれる内容の要旨
12.3 Outdoor Fan Motor Operation ....................31 12.4 Airflow Direction..........................................31 12.5 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)...............................................32 12.6 Quiet Operation (Heating) ..........................32 12.7 Powerful Mode Operation...........................33 12.8 Timer Control..............................................33 12.9 Auto Restart Control...................................33 12.10 Indic
ページ3に含まれる内容の要旨
1. Safety Precautions Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction
ページ4に含まれる内容の要旨
19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping and valves at opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.). 20. During pump down operation, stop the compressor before remove the refrigeration piping. (Removal of refrigeration piping while compressor is operating and valves are opened condition
ページ5に含まれる内容の要旨
2. Specification Indoor CS-E9NKUAW CS-E12NKUAW Model Outdoor CU-E9NKUA CU-E12NKUA Performance Test Condition ARI ARI Phase, Hz Single, 60 Single, 60 Power Supply V 208 230 208 230 Min. Mid. Max. Min. Mid. Max. Min. Mid. Max. Min. Mid. Max. kW 1.20 2.49 3.00 1.20 2.49 3.00 1.20 3.51 3.90 1.20 3.51 3.90 Capacity BTU/h 4100 8500 10200 4100 8500 10200 4100 12000 13300 4100 12000 13300 Running Current A - 3.5 - - 3.1 - - 5.2 - - 4.7 - Input Power W 250 650 850 250 650 850 250 1.00k 1.15k
ページ6に含まれる内容の要旨
Type Propeller Propeller Material PP PP Motor Type DC (8 poles) DC (8 poles) Input Power W - - Output Power W 40 40 Speed Hi rpm C: 830 H: 780 C: 830 H: 780 Moisture Removal L/h (Pt/h) 0.6 (1.3) 1.2 (2.5) Cooling : 5.42 (191) Cooling : 5.30 (187) 3 3 QLo m /min (ft /min) Heating : 6.49 (229) Heating : 8.75 (309) Cooling : 6.51 (230) Cooling : 6.98 (246) 3 3 Lo m /min (ft /min) Heating : 7.53 (266) Heating : 9.78 (345) Cooling : 8.80 (3 11) Cooling : 9.49 (335) 3 3 Indoo
ページ7に含まれる内容の要旨
DRY BULB WET BULB DRY BULB WET BULB Maximum 89.6 73.4 89.6 73.4 Indoor Operation Range (Cooling) Minimum 60.8 51.8 60.8 51.8 Maximum 109.4 78.8 109.4 78.8 Outdoor Operation Range (Cooling) Minimum 5.0 - 5.0 - Maximum 86.0 - 86.0 - Indoor Operation Range (Heating) Minimum 60.8 - 60.8 - Maximum 75.2 64.4 75.2 64.4 Outdoor Operation Range (Heating) Minimum 5.0 3.2 5.0 3.2 1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°
ページ8に含まれる内容の要旨
3. Features Inverter Technology o Wider output power range o Energy saving o Quick Cooling o More precise temperature control Environment Protection o Non-ozone depletion substances refrigerant (R410A) Long Installation Piping o CS/CU-E9/12NK, long piping up to 20 meters Easy to use remote control Quality Improvement o Random auto restart after power failure for safety restart operation o Gas leakage protection o Prevent compressor reverse cycle o Inner protector to
ページ9に含まれる内容の要旨
4. Location of Controls and Components 4.1 Indoor Unit 4.2 Outdoor Unit 4.3 Remote Control 9
ページ10に含まれる内容の要旨
5. Dimensions 5.1 Indoor Unit 10
ページ11に含まれる内容の要旨
5.2 Outdoor Unit 11
ページ12に含まれる内容の要旨
6. Refrigeration Cycle Diagram 12
ページ13に含まれる内容の要旨
7. Block Diagram 13
ページ14に含まれる内容の要旨
8. Wiring Connection Diagram 8.1 Indoor Unit 14
ページ15に含まれる内容の要旨
8.2 Outdoor Unit 15
ページ16に含まれる内容の要旨
9. Electronic Circuit Diagram 9.1 Indoor Unit 16
ページ17に含まれる内容の要旨
9.2 Outdoor Unit 17
ページ18に含まれる内容の要旨
10. Printed Circuit Board 10.1 Indoor Unit 10.1.1 Main Printed Circuit Board 18
ページ19に含まれる内容の要旨
10.1.2 Power Printed Circuit Board 10.1.3 Indicator Printed Circuit Board 19
ページ20に含まれる内容の要旨
10.2 Outdoor Unit 10.2.1 Main Printed Circuit Board 20