Master Lock E72 user manual

User manual for the device Master Lock E72

Device: Master Lock E72
Category: Door
Manufacturer: Master Lock
Size: 0.51 MB
Added : 4/18/2014
Number of pages: 21
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Master Lock E72. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Master Lock E72.

For your convenience

If looking through the Master Lock E72 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Master Lock E72 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Master Lock E72 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Master Lock E72 User manual - Online PDF
Advertisement
« Page 1 of 21 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Master Lock E72 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Master Lock E72. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.sdcsecurity.com
Visit our website for more information on
our complete product line, new product
announcements, pricing, installation
instructions and templates.
M:\INS\INST-E72 Prog. Guide 0701

Summary of the content on the page No. 2

Introduction T Add Group Schedule able of Contents Function 03 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Congratulations, you have just purchased the E72 EntryCheck by SDC, the most advanced stand-alone Battery Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv door lock and access control system on the market t

Summary of the content on the page No. 3

Before You Begin Battery Information KEYPAD INFORMATION Batteries The E72 EntryCheck keypad has two special keys: the Terminator and the Programming key. THE E72 IS SHIPPED WITH 4 AA ALKALINE BATTERIES. The life span of the batteries has been tested in • Terminator - This key functions like the “enter” key on a computer. Once the terminator is pressed, two different ways. the information entered is saved. The default terminator key for the E72 is “*”. • Programming key - This key is used wh

Summary of the content on the page No. 4

Function 03 Add Group Schedule Resetting the E72 Group Security Levels RESETTING THE E72 NOTE: GROUPS 02-09 ARE RESERVED FOR MANAGEMENT LEVEL PERSONNEL. There may be a time when you need to fully reset your E72 and start over. If you reset the E72, all SCHEDULING FUNCTIONS CANNOT RESTRICT THESE USERS. previous information in the lock memory will be lost. (This includes: users, scheduling, GGM code, E72 ID and lock settings.) Group Name Group No. Description Factory Code None Factory code “9

Summary of the content on the page No. 5

Function 03 Sample Function P Add Group Schedule rogramming Page Initialize Lock ID Level: Master Function Name Function Number Function 03 Group Schedule The LOCK ID INITIALIZATION process can be implemented ONLY using the FACTORY CODE. This occurs when: Level: Master Minimum Group Function Description • The lock is first installed Security Level Function schedules OPEN and CLOSE time/day for an established GROUP of • After the lock has been reset. (See page v.) Needed To users. This functi

Summary of the content on the page No. 6

Initialize Great Grand Master Function 12 Set Time Level: Master Level: Master When the Great Grand Master (GGM) is entered it has the two components that are found in all codes. TIME MUST BE SET PRIOR TO ACTIVATING SCHEDULING. 1. User ID (UID) 3 to 4 DIGITS This function SETS the INTERNAL TIME of the LOCK. The lock uses military time and is automatically 2. Pin Number (PIN) 3 to 6 DIGITS/ALPHA/MULTIPLE KEY DEPRESSIONS updated when the upload/download module (IDT) is used. Ex. 1530=3:30 p.m.

Summary of the content on the page No. 7

Set Date / Format Function 13 Function 01 User Maintenance Level: Master Level: Master DATE MUST BE SET PRIOR TO ACTIVATING SCHEDULING. This function creates NEW users or deletes EXISTING users. All USERS are REQUIRED to have a GROUP This function SETS the MONTH, DAY, YEAR and DAY OF THE WEEK. NUMBER (See page iii). GGM Code sets standard length format for all USER CODES. (See page iii.) ENTRIES VISUAL / AUDIO ENTRIES VISUAL / AUDIO 1. # Valid User Code 1. # Valid User Code 2. Function Number 0

Summary of the content on the page No. 8

Function 03 Group Schedule Basic Schedule Function 02 Level: Master Level: Master The BASIC SCHEDULE function is a powerful tool that recognizes those scheduling TIMES that GROUPS Function schedules OPEN and CLOSE time/day for an established GROUP (10-99) of users. This function have in COMMON. It was designed to give an overall framework to the lock effectively minimizing differs from the Basic Schedule (Func. 02), in that specific GROUPS can be granted access. scheduling under other more cumb

Summary of the content on the page No. 9

User Schedule Function 04 Function 05 Schedule Passage Mode Level: Master Level: Master Function schedules OPEN and CLOSE time/day for INDIVIDUAL user. This function is intended to work in Function SCHEDULES TIMES the lock will enter the PASSAGE MODE and when it will return to restricted conjunction with an existing group schedule. Ex. User “A” belongs to group “25” with access from 8 am-6 pm Valid User Code entry. For MANUAL PASSAGE MODE see Func. 30. Mon.-Fri. User “A” also comes in Sat.

Summary of the content on the page No. 10

Temporary User Schedule Function 06 Function 07 Change Group Association Level: Master Level: Master Function allows an existing USER to be flagged as a TEMPORARY USER. The TEMPORARY USER will This function allows a USER to be REMOVED from one group and ENROLLED in another existing group. function as a normal user and will have a schedule assigned to them for access rights. The TEMPORARY Once enrolled in the new group, the USER conforms to the new group schedule. USER CODE will become invalid

Summary of the content on the page No. 11

Change User PIN Function 08 Function 09 Holiday Maintenance Level: User Level: Master Function DENYS USERS ACCESS on an observed HOLIDAY. The lock views dates between the start date Function allows the USER to CHANGE their PIN. The change user PIN function adds overall security to the and the end date as one holiday no matter how many days might actually exist. locks by allowing users to change a compromised PIN at their discretion. Management can prevent PIN Ex.: Start Date 12/24, End Date

Summary of the content on the page No. 12

Deny/Restore Access To Selected Groups Function 10 Function 11 Set Access Level Level: Master Level: Master This function allows RESTRICTED ACCESS to SELECTED USER GROUPS without erasing the group/groups ACCESS is DENIED to ALL GROUPS with access levels LOWER than the ENTERED GROUP. In order to from memory. Once access has been denied to a group/groups then access must be restored using this restore access to all groups this function must be used by a manager with a security level equal to or

Summary of the content on the page No. 13

Clear Memory Function 16 Function 17 Battery Status Check Level: Grand Master Level: Security Guard Group This function will CLEAR the MEMORY of the lock and/or CLEAR ALL SCHEDULES, DATE AND TIME. Function DISPLAYS the BATTERY STATUS using the LED DISPLAY on the keypad as shown below. This makes regular maintenance as easy as possible. Battery status will also be displayed on audit trail. Enter "0" to CLEAR ALL USERS, DATE, TIME, SCHEDULES & FUNCTIONS. (EXCEPT GGM and LOCK ID.) DO NOT USE LITHI

Summary of the content on the page No. 14

Define Open Time Function 18 Function 30 Manual Passage Mode Level: Master Level: Master This function SETS the time the lock will REMAIN OPEN to allow access. The time INTERVAL may vary Manual Passage Mode is designed to allow free access to the door. between 1-9 SECONDS. Shorter open times help to prevent tailgating. If user opens the door within the set There are two types of passage mode: time, access will be granted. 1. Entered at the door. 2. Schedule Passage Mode. (See Func. 05.) E

Summary of the content on the page No. 15

First Supervisor to Arrive Function 31 Function 32 Pin Only Entry Level: Grand Master Level: Grand Master This function will override the set schedule, denying USERS access until a user with a MINIMUM ACCESS Function allows a SHORTER LENGTH OF CODE to be entered by the user to gain access. OF SUPERVISOR (02-04) enters their code. After a supervisor enters their code, the schedule will resume When ENABLED, user enters their PIN number FOLLOWED BY “ ”. * from that point. The POSSIBLE PROBLEMS t

Summary of the content on the page No. 16

Double Code Entry Function 33 Function 34 Lock Audio Level: Grand Master Level: Master The function REQUIRES 2 VALID USER CODES to be entered in order to gain access. For higher security LOCK AUDIO is designed to give an audio feedback from internal sounding unit. The lock keypad has an restrictions, this function can also be set to require one of the codes to be of Management Level. When set audible click which sounds at all times with every keystroke. for this option, the first user will e

Summary of the content on the page No. 17

Fail Secure Function 36 Function 37 Set Alternative Terminator Level: Grand Master Level: Grand Master THIS FUNCTION IS ONLY INTENDED FOR USE IN BATTERY POWERED UNITS. This function increases the SECURITY of the lock by REVERSING the TERMINATOR and PROGRAMMING In case the low battery warning goes unnoticed, (See Battery Information page iv) and the lock runs out of KEYS. This reversal adds another level of complexity to any attempt at hacking codes. (For more power, this function ensures that

Summary of the content on the page No. 18

Upload Lock Information Function 14 Function 15 Download Audit Trail Level: Security Guard Level: Security Guard This function will take the information stored in the IDT and upload and update the E72’s memory. Any Function will DOWNLOAD the E72 audit trail to the IDT. The number of events downloaded are user defined changes made at the door via the keypad and not updated in the computer will be lost once the update is but limited to your upgrade option. For the standard E72, the maximum num

Summary of the content on the page No. 19

Lock Upgrade Function 20 Function 35 IR Interrupt Level: Master Level: Grand Master This function is used to upgrade the memory of your E72. Here are the steps. This function PREVENTS IR transmission between the lock and the IDT Upload/Download device for extra security. 1. Obtain the lock serial number. The serial number is printed on the exterior backplate of the E72. To DISABLE the IR Interrupt, enter "0". Or, using the IDT, the serial number appears on the IDT display, as well as, on the he

Summary of the content on the page No. 20

Glossary Military Time Conversion Chart Access code Numeric or alphanumeric data which when correctly entered into a keypad, allows Standard Time Military Time authorized entry into a controlled area without causing an alarm condition. Access control The control of persons, vehicles and materials through entrance and exit of a protected 1:00 a.m..................................0100 area utilizing hardware systems specialized procedures to control and monitor the 2:00 a.m........................


Alternative user manuals
# User manual Category Download
1 Master Lock BUILT-IN COMBINATION LOCKS 1651MKMDADA User manual Door 3
2 Master Lock BUILT-IN COMBINATION LOCKS 1651MKADA User manual Door 2
3 Master Lock BUILT-IN COMBINATION LOCKS 1652MD User manual Door 0
4 Master Lock BUILT-IN COMBINATION LOCKS 1653MD User manual Door 0
5 Master Lock BUILT-IN COMBINATION LOCKS 1656MKADA User manual Door 0
6 Master Lock BUILT-IN COMBINATION LOCKS 1656MKMDADA User manual Door 0
7 Master Lock BUILT-IN COMBINATION LOCKS 1652 User manual Door 0
8 Master Lock BUILT-IN COMBINATION LOCKS 1653 User manual Door 0
9 Master Lock Masterlock 1500HD User manual Door 13
10 Master Lock dialSpeed Electronic Combination Lock 1500eD User manual Door 32
11 Sony SCHLAGE LINK BE369 User manual Door 6
12 3Com TECHD-0000000050 User manual Door 1
13 Ace Hardware User manual Door 1
14 American Standard 6034.STE2 User manual Door 0
15 American Standard 6000.STE1 User manual Door 1