Summary of the content on the page No. 1 
                    
                        Installation/Operation Manual with Service Replacement Parts
Undercounter
Dishwashers
(with pumped final rinse)
Models: 
201HT	 	 High temperature w/booster 	 	
201HTN	 	 High temperature w/o booster
201L T	 	 Low temperature chemical sanitizing
201HT
401HT		 High temperature w/booster
401HTN	 	 High temperature w/o booster
501HT	 	 High temperature w/booster 	
501HTN	 	 High temperature w/o booster
501L T  Low temperature chemical sanitizing
401HT
Dishwasher serial no.
501HT
Issue Date:  3.15.1
                    
                    Summary of the content on the page No. 2 
                    
                        For future reference,  record your dishwasher information in the box below. 	   Model Number__________________________   Serial Number_______________________ Voltage________________Hertz_____________ Phase__________________    Service Agent _________________________________________Tel:______________________ Moyer Diebel Parts Distributor _________________________________ Tel:______________________ National Service Department - Canada   National Service Department -USA Toll-free: 800/ 263-5798 To
                    
                    Summary of the content on the page No. 3 
                    
                        In	Canada	you	can 	 Register 	by	Postage	Paid	Mail:  Cut along the dashed lines, then complete the back of the postage paid card above and mail  immediately to validate your machine warranty. OR REGISTER 	 YOUR	PRODUCT	ONLINE Make sure you are connected to the internet then click or enter the address below. In	the	U.S.A http://www .moyerdiebel.com/register In	Canada http://www .championindustries.com/canada/register                                                                                 
                    
                    Summary of the content on the page No. 4 
                    
                        PRODUCT REGISTRATION CARD Model Serial # Date of Installation: Company Name: Address: (Street) Province Postal Code  Telephone #:   (        )               --- Contact: Installation Company: Address: Telephone #: Contact: FAILURE TO REGISTER YOUR PRODUCT MAY VOID YOUR WARRANTY IMPORTANT       IMPORTANT REGISTER 	 YOUR	PRODUCT	ONLINE Make sure you are connected to the internet then click or enter the address below. In	the 	U.S.A http://www .moyerdiebel.com/register In	Canada http://www .champion
                    
                    Summary of the content on the page No. 5 
                    
                        Revision	 History 		 Revision	 History 	 We reserve the right to make changes to this manual without notice and without incurring any liability by making the  changes. Equipment owners may request a revised manual, at no charge, by calling 1 (800) 858-4477 in the USA  or  by calling 1 (800) 263-5798 in Canada. Revision	 Revised	 Serial 	Number	 		 	 Revision	 	 	 	 	 	 	 	 	 	 	 	 	 			Date	 Pages	 Ef fectivity	 Description 	   9.15.06	 All	 W1 1948	 	 	 Released	 first 	 edition 	 3.22.07	 59	 
                    
                    Summary of the content on the page No. 6 
                    
                        Revision 	History Revision	History	 (continued) Revision	 Revised	 Serial 	Number	 	 		Revision	 												 			Date	 Pages	 Ef fectivity	 	 Description ii                                                                                                                                                                                                                                                                                                                                                        
                    
                    Summary of the content on the page No. 7 
                    
                        Blank	 Page This	Page 	 Intentionally 	 Left	Blank iii                                                                                                                                                                                                                                                                                                                                                                                                                                                              
                    
                    Summary of the content on the page No. 8 
                    
                        Limited	W arranty LIMITED WARRANTY Moyer Diebel, 3765 Champion Boulevard, Winston-Salem, North Carolina  27105, and P.O. Box 301, 2674 N. Service Road,   Jordan Station, Canada, L0R 1S0, warrants machines, and parts, as set out below.  Warranty of Machines: Moyer Diebel warrants all new machines of its manufacture bearing the name     "Moyer Diebel" and installed within the United States and Canada to be free from defects in material and workman   ship for a period of one (1) year after the date
                    
                    Summary of the content on the page No. 9 
                    
                        T able	of	 Contents 	 T able 	of	Contents Model	201, 	401,	501	Undercounter 	Dishwashers Revision	History	 	 ........................................................................................................... i Limited	W arranty	 	 ........................................................................................................... ii Model	Descriptions	 	 ........................................................................................................... iv Installation ...
                    
                    Summary of the content on the page No. 10 
                    
                        Model	Description Model Description 201-HT, 401-HT, and 501-HT Models Pumped final rinse high temperature sanitizing dishwasher with built-in 40°F rise stainless steel electric booster.  Single Phase to Three Phase Field Conversion. 201-HTN, 401-HTN, and 501-HTN Models Pumped final rinse high temperature sanitizing dishwasher without built-in 40°F rise stainless steel electric booster. 201-LT, 501-LT Model Pumped final rinse low temperature chemical sanitizing dishwasher with 3 built-in chemical
                    
                    Summary of the content on the page No. 11 
                    
                        Installation Receiving   NOTE: The installation of your dishwasher must be performed by qualified service personnel.   Problems due to improper installation are not covered by the Warranty.  1. Inspect the outside of the dishwasher carton for signs of damage. 2. Remove the carton and inspect the dishwasher for damage. 3. Check for any accessories that may have shipped with your dishwasher. 4. Turn to the front of this manual and follow the instructions to register your machine online. 5. Move th
                    
                    Summary of the content on the page No. 12 
                    
                        Installation Electrical Connections  For Model 201HT, 401HT, and 501HT machines beginning with S/N 14236 and above 1. Refer to the connection diagrams below. 2. Models 201HTN /LT, 401HTN,  501HTN /LT are equipped with a    4 ft. power cord/plug and only require a 115VAC,15A receptacle. 3. Models 201HT, 401HT, and 501HT  1 PH machines require a   3-wire plus ground supply which includes a current carrying neutral. 4. Models 201HT, 401HT, and 501HT  3 PH machines   require a 4-wire plus ground sup
                    
                    Summary of the content on the page No. 13 
                    
                        Installation Electrical Connections  For machines built prior to S/N 14236 WARNING: Electrocution or serious injury may result when working on an  energized circuit.   Disconnect power at the main breaker or service disconnect  switch before working on the circuit.   Lock-out and tag the breaker to indicate that work is being  performed on the circuit.  ATTENTION  A qualified electrician must connect the main incoming power to the dishwasher in accordance with all local  codes and regulations or
                    
                    Summary of the content on the page No. 14 
                    
                        Installation Electrical Connections (continued) For Models 201HT, 401HT, and 501HT beginning with S/N 14236 and above WARNING: Electrocution or serious injury may result when working on an  energized circuit.   Disconnect power at the main breaker or service disconnect  switch before working on the circuit.   Lock-out and tag the breaker to indicate that work is being  performed on the circuit.  Booster Heater Element  Field Conversion from Single to Three Phase Operation   Dishwashers shipped f
                    
                    Summary of the content on the page No. 15 
                    
                        Installation Booster Heater Element  Field Conversion from Single to Three Phase Operation (continued)   Main Terminal Block (MTB) ATTENTION ELECTRICIAN: No power when booster heater is connected for 1 PH The Main Terminal Block (MTB) is a 4-wire  connection block which includes a current-carrying  neutral. The block can be connected for 3PH or 1PH  depending on how the booster  heater is wired (  see the previous page). Refer to the diagram to the  L1 L2 L3 N right and connect the main incoming
                    
                    Summary of the content on the page No. 16 
                    
                        Installation Water Connections    NOTE Plumbing connections must comply with national, local plumbing and sanitary codes. IMPORTANT  Make sure that the flexible water supply and drain hoses are not kinked. 1. All models have a 6 ft./1.8m flexible hot water fill hose with a 3/4" female garden hose  connector.  2. A 1/2" or larger main incoming supply line should be installed to the dishwasher.    3. A 1/2" or larger shut-off valve should be installed in the main water supply as close to the  dish
                    
                    Summary of the content on the page No. 17 
                    
                        Installation Drain Connections  ATTENTION Do not connect the drain hose to a disposer. The dishwasher will not drain correctly. NOTE The dishwasher drains in 8 seconds and drain water exits the hose with considerable force. 1. All models have a 6 ft. 5/8" I.D. drain hose. The maximum drain height connection  must not exceed  3 ft.[0.9 m].   2. The drain hose is located at the rear of the dishwasher. A 5/8" hose-barb fitting is  strapped to the drain hose to connect the drain hose. 3. The drain h
                    
                    Summary of the content on the page No. 18 
                    
                        Initial Start-up Filling the Booster For Models 501HT, 401HT, and 201HT Note: The dishwasher contains a built-in booster heater that was drained prior to shipment   and must be filled with water before operating the dishwasher.  Booster Fill Switch The booster heater is filled using the Booster  Fill Switch. It is located behind the lower front  access panel in the center of the bracket that  holds the chemical dispensing pumps (see the  photos to the right). Fill the booster heater: 1. Make sur
                    
                    Summary of the content on the page No. 19 
                    
                        Initial Start-up Check List All Models 1. Remove any protective film from dishwasher.    2. Check the interior for foreign material.   3. Make sure the dishwasher is permanently located.  4. Make sure all utility connections are complete.  5. Make sure the flexible drain hose and the hot water fill hose are not kinked.  6. Make sure that the chemical supply containers are full and the chemical pick-up tubes  are installed in the proper containers.  7. Make sure the scrap screen is in place.  8. 
                    
                    Summary of the content on the page No. 20 
                    
                        Initial Start-up Chemical Dispensing Pumps Models 501HT, 501HTN, 401HT, 401HTN, 201HT, 201HTN 1. Models 201HT, 201HTN, 401HT, 401HTN, 501HT, and 501HTN: are equipped with a built-in detergent dispensing pump and a rinse-aid dispensing pump. The pumps are located behind the lower front access panel.                                   Chemical Injection Point    Chemical Dispensing Pumps for     Chemical Pick-up Tubes,  High Temperature HT and HTN   stiffener tubes & line  Models. strainers.      2