National Instruments CFP-RLY-421 user manual

User manual for the device National Instruments CFP-RLY-421

Device: National Instruments CFP-RLY-421
Category: Electronic Accessory
Manufacturer: National Instruments
Size: 0.37 MB
Added : 4/20/2014
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments CFP-RLY-421. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments CFP-RLY-421.

For your convenience

If looking through the National Instruments CFP-RLY-421 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments CFP-RLY-421 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments CFP-RLY-421 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments CFP-RLY-421 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments CFP-RLY-421 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments CFP-RLY-421. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

FieldPoint Operating Instructions
CFP-RLY-421
Eight-Channel SPST Relay Module
These operating instructions describe how to install and use the
National Instruments cFP-RLY-421 relay module. For details on
configuring and accessing the cFP-RLY-421 over a network, refer
to the user manual for the FieldPoint network module you are
using.
Features
The cFP-RLY-421 is a Compact FieldPoint relay output module
with the following features:
• Eight single-pole single-throw (SPST) relay channels
 Swi

Summary of the content on the page No. 2

Before you configure a FieldPoint system that uses a cFP-RLY-421 module, calculate the total power consumption of the I/O modules on the FieldPoint bank. You can find the power requirement specification in the operating instructions for each I/O module. The maximum power the network module can supply is specified in the network module user manual. Make sure the total power requirement for all of the I/O modules in the bank is less than the maximum power available from the network module.

Summary of the content on the page No. 3

5 2 1 4 5 4 3 1 cFP I/O Module 4 Screw Holes 2 Captive Screws 5 cFP Backplane 3 cFP Controller Module Figure 1. Installing the cFP-RLY-421 Wiring the cFP-RLY-421 The cFP-CB-x connector block has connections for each of the eight cFP-RLY-421 relay channels and for an external supply to power field devices. If you are using the cFP-RLY-421 in a hazardous voltage application, you must use the cFP-CB-1 connector block or a suitable hazardous voltage cable. A hazardous voltage is a voltage grea

Summary of the content on the page No. 4

Table 1 lists the terminal assignments for the signals of each channel. Table 1. Terminal Assignments Terminal Numbers Channel NO IC 0 1 2 1 3 4 2 5 6 3 7 8 4 9 10 5 11 12 6 13 14 7 15 16 All of the COM terminals are connected internally and all of the V terminals are connected internally. NI does not recommend SUP using them with the cFP-RLY-421. Table 2. V and COM Terminal Assignments SUP V COM SUP 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Caution Cascading power between two modules

Summary of the content on the page No. 5

Connecting Loads to the cFP-RLY-421 Wire an external power supply to the load and IC terminal of the individual channel as shown in Figure 2. This method of wiring keeps the electrical connections of the cFP-RLY-421 within safe current limits. V C V SUP NO Sourcing + Load or IC – AC COM To next channel cFP-RLY-421 Figure 2. Connecting a Load The cFP-RLY-421 has eight SPST (Single-Pole-Single-Throw) electromechanical relays. The power-up state is off (open) to ensure safe installation. In

Summary of the content on the page No. 6

In addition, the cFP-RLY-421 has internal protection MOVs to prevent excessively high voltage from being applied across the contacts. The MOVs are located between the NO and IC contacts of each relay. However, National Instruments still recommends the use of a protection circuit across an inductive load. The flyback protection causes a small leakage current, which is detailed in the Specifications section. Guidelines for Selecting Contact 1 Protection Circuits Proper selection is critical

Summary of the content on the page No. 7

Diode Circuit Diagram Notes Use in DC applications only. Compared to RC type, circuit delays release time (2 to 5 times values stated in catalog). For larger voltages, use diode with reverse breakdown 10 times circuit voltage and forward load circuit. Load For smaller voltages, use reverse breakdown voltage of 2 to 3 times power supply voltage. CR Circuits Diagram Notes Circuit A is suitable for AC or DC applications, but if used with AC voltage, impedance of the load should be smalle

Summary of the content on the page No. 8

In-Rush Current The type of load and its in-rush current characteristics, together with switching frequency, can cause contact welding. For loads with in-rush current, measure the steady state current and in-rush current to determine the proper relay. Some typical types of loads and the in-rush current they create are summarized in the following chart. Type of Load In-Rush Current Resistive load Steady-state current Solenoid load 10 to 20 times the steady-state current Motor load 5 to 10 ti

Summary of the content on the page No. 9

Upgrading the FieldPoint Firmware You may need to upgrade the FieldPoint firmware when you add new I/O modules to the FieldPoint system. For information on determining which firmware you need and how to upgrade the firmware, go to ni.com/info and enter fpmatrix. Isolation and Safety Guidelines Caution Read the following information before attempting to connect the cFP-RLY-421 to any circuits that may contain hazardous voltages. This section describes the isolation of the cFP-RLY-421 and its

Summary of the content on the page No. 10

Do not share the external supply voltages (the V and C terminals) with other devices (including other FieldPoint devices), unless those devices are isolated from human contact.  You must connect the protective earth (PE) ground terminal on the cFP-BP-x backplane to the system safety ground. The backplane PE ground terminal has the following symbol stamped beside it: . Connect the backplane PE ground terminal to the system safety ground using 14 AWG (1.6 mm) wire with a ring lug. Use the

Summary of the content on the page No. 11

Specifications The following specifications are typical for a range of –40 to 60 °C unless otherwise noted. Relay Characteristics Number of channels..........................8 Relay type .........................................1 SPST, nonlatching Maximum switching capacity (resistive load) –40 to 60 °C AC ........................................1.5 A at 250 VAC DC........................................1.5 A at 0 to 35 VDC 1 A at 55 VDC 0.4 A at 120 VDC Minimum switching load.................

Summary of the content on the page No. 12

Physical Indicators ..........................................Green POWER and READY indicators, 8 green output state indicators Weight cFP-RLY-421..............................130 g (4.5 oz) Power Requirements Power from network module ............1,700 mW Isolation Voltage Maximum isolation voltage ..............250 V rms Channel-to-channel isolation............No isolation between channels Transient overvoltage........................2,300 V rms Environmental FieldPoint modules are intende

Summary of the content on the page No. 13

Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use:  IEC 61010-1, EN 61010-1  UL 3121-1, UL 61010C-1  CAN/CSA C22.2 No. 1010.1 For UL, hazardous location, and other safety certifications, refer to the product label or to ni.com. Electromagnetic Compatibility CE, C-Tick, and FCC Part 15 (Class A) Compliant Emissions..........................................EN 55011 Class A at 10

Summary of the content on the page No. 14

Where to Go for Support For more information about setting up the FieldPoint system, refer to these National Instruments documents:  FieldPoint network module user manual  Other FieldPoint I/O module operating instructions  FieldPoint connector block operating instructions Go to ni.com/support for the most current manuals, examples, and troubleshooting information. For telephone support in the United States, create your service request at ni.com/ask and follow the calling instructions or


Alternative user manuals
# User manual Category Download
1 National Instruments EIGHT CHANNEL SPST RELAY MODULE User manual Electronic Accessory 0
2 National Instruments NI-845x Software and Hardware User manual Electronic Accessory 0
3 National Instruments NI-845x User manual Electronic Accessory 1
4 Sony In-car Cradle User manual Electronic Accessory 0
5 Sony 7011458 User manual Electronic Accessory 1
6 Agilent Technologies U1251A User manual Electronic Accessory 33
7 Samsung HL-P5067W User manual Electronic Accessory 0
8 Samsung HL-P6167W User manual Electronic Accessory 1
9 Samsung HL-P5667W User manual Electronic Accessory 0
10 Behringer EURODESK MX9000 User manual Electronic Accessory 57
11 Black Box AC504A User manual Electronic Accessory 1
12 Black Box ACX1000-MS User manual Electronic Accessory 3
13 Black Box ACX1000-CM User manual Electronic Accessory 0
14 Black Box ICS02A User manual Electronic Accessory 0
15 Black Box ACX1000 User manual Electronic Accessory 0