Honeywell ML6425 user manual

User manual for the device Honeywell ML6425

Device: Honeywell ML6425
Category: Automobile Parts
Manufacturer: Honeywell
Size: 0.82 MB
Added : 3/27/2013
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell ML6425. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell ML6425.

For your convenience

If looking through the Honeywell ML6425 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell ML6425 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell ML6425 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell ML6425 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell ML6425 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell ML6425. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ML6425, ML7425 Spring Return
Electric Linear Valve Actuators
PRODUCT DATA
FEATURES
ML6425 and ML7425
• Accurate valve positioning.
• Quick and easy installation.
• No separate linkage required.
• On power failure:
ML6425A and ML7425A drive valve stem down.
ML6425B and ML7425B draw valve stem up.
• Conduit connector is standard.
• No adjustments required.
• True spring return on power failure.
• Low power consumption.
• High close-off ratings.
• Force-limiting end switches.
• Direct/reverse acti

Summary of the content on the page No. 2

ML6425, ML7425 SPRING RETURN ELECTRIC LINEAR VALVE ACTUATORS SPECIFICATIONS Models: Storage: -40° to +158° F (-40° to +70° C). Maximum Valve Medium: 300° F (149° C). Model Spring Return Action Description ML6425A Drive valve stem down on power Electric Humidity: 5 to 95 percent relative humidity, noncondensing. failure Linear Valve ML7425A Actuator Close-off Pressure Ratings: Refer to Table 1. ML6425B Draw valve stem up on power failure Protection Standard: IP54. ML7425B Approvals: Dimensions:

Summary of the content on the page No. 3

ML6425, ML7425 SPRING RETURN ELECTRIC LINEAR VALVE ACTUATORS Table 1. Close-off Ratings for ML6425, ML7425 Electric Linear Valve Actuators and Honeywell Valves (psi). Type Valve 1/2 in. 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. 3 in. FlangeV5011A — ———— —28 16 V3350/ 3351/ 3450/ 3451 — ———— —21 14 a a V5013B, C; V3360/ 3361/ 3460/ 3461 — ———— — 21 14 b b b b NPT V5011F, G 77 49 28 16 150 150 134 150 V5011H, J 150 150 150 145 — — — — V5011N1xxx, V5011N3xxx, V5013N 230 230 163 104 67 37 —

Summary of the content on the page No. 4

ML6425, ML7425 SPRING RETURN ELECTRIC LINEAR VALVE ACTUATORS M6629 Fig. 5. Removing Spring Retaining Clip and Releasing Manual Spring Handle. M6632 Fig. 2. Attaching Actuator to Valve Collar. WIRING CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. All wiring must comply with local electrical codes, ordinances and regulations. Voltage and frequency of the transformer used with the actuator must

Summary of the content on the page No. 5

ML6425, ML7425 SPRING RETURN ELECTRIC LINEAR VALVE ACTUATORS ML6425A,B WIRING T6984 (FLOATING CONTROLLER) ML7425 4 2 STRIP WIRING MOTOR OPEN 2 B STRIP MOTOR CLOSE INPUT F W F (FEEDBACK) 24 Vac OUTPUT + + COMMON – 3 – T2 T1 T5 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS T1 O1 AND OVERLOAD PROTECTION AS REQUIRED. O2 2 ALL WIRING BLOCKS HAVE THE SAME TS NUMBER OF TERMINALS (8), BUT THE ONLY 1 TERMINALS THAT ARE ACTIVE ON THIS 3 T L1 BLOCK ARE T1, T5, W, AND B. (HOT) Y 3 THE T-Y-G TERMINALS ARE

Summary of the content on the page No. 6

ML6425, ML7425 SPRING RETURN ELECTRIC LINEAR VALVE ACTUATORS SENSOR ML7425 ML7425 SENSOR WIRING WIRING 1 2 3 4 5 6 1 2 3 4 5 6 STRIP STRIP 1 1 F L1 F L1 (HOT) + (HOT) + L2 L2 – – SINGLE SINGLE TRANSFORMER T2 T2 TRANSFORMER 3 2 1 2 1 40 VA 24 VAC 3 T1 40 VA 24 VAC T1 O1 O1 500 OHM O2 RESISTOR O2 T775 T775 (WITH 2-10 VDC OUTPUT) TS TS (WITH 4-20 MA OUTPUT) 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS M7895 AND OVERLOAD PROTECTION AS REQUIRED. M7897 AND O

Summary of the content on the page No. 7

ML6425, ML7425 SPRING RETURN ELECTRIC LINEAR VALVE ACTUATORS ML7425 W3 W2 W1 Signal Input (+) The analog input signal (+) range is set at the factory to 0 to 10 Vdc. Changing the position of the W2 selector plug sets the 0% 50% 100% range to 2 through 10 Vdc. Selector plugs W1, W2, and W3 are positioned on the back side of the printed circuit board. Refer to Fig. 15 for location of the selector plugs. Signal Input Failure Using the potentiometer, the actuator can be set to run to any positi

Summary of the content on the page No. 8

ML6425, ML7425 SPRING RETURN ELECTRIC LINEAR VALVE ACTUATORS up on decreasing signal. When the valve stem is up, the Direction of Action (ML7420/ML7425 only) output signal from the feedback (F) function is 0 or 2 Vdc. The The direction of actuator action can be changed using the output of the signal does not change when W3 is used to pushbutton and LED, which is factory set so that the actuator reverse the action of the actuator (see Fig. 15). drives the valve stem down on increasing signal


Alternative user manuals
# User manual Category Download
1 Honeywell 500 User manual Automobile Parts 22
2 Honeywell EXCEL 10 W7751H User manual Automobile Parts 99
3 Honeywell HERCULINE 2000 User manual Automobile Parts 59
4 Honeywell ALF502L User manual Automobile Parts 2
5 Honeywell ALF502R User manual Automobile Parts 2
6 Honeywell V4055F User manual Automobile Parts 0
7 Honeywell LF507 User manual Automobile Parts 0
8 Honeywell 2000 User manual Automobile Parts 1
9 Honeywell M7410F User manual Automobile Parts 3
10 Honeywell M6410A User manual Automobile Parts 5
11 Honeywell C7150B User manual Automobile Parts 1
12 Honeywell V4055G User manual Automobile Parts 0
13 Honeywell ML7425 User manual Automobile Parts 4
14 Honeywell M8405 User manual Automobile Parts 10
15 Honeywell M847D User manual Automobile Parts 58
16 Sony BP-GL95 User manual Automobile Parts 25
17 Sony BP-GL65 User manual Automobile Parts 2
18 Philips Epic 50PF9966 User manual Automobile Parts 3
19 Philips HTS3011 User manual Automobile Parts 2
20 Philips SDJ6040W User manual Automobile Parts 1