Omega FD6001 user manual

User manual for the device Omega FD6001

Device: Omega FD6001
Category: Automobile Parts
Manufacturer: Omega
Size: 2.01 MB
Added : 11/21/2014
Number of pages: 47
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega FD6001. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega FD6001.

For your convenience

If looking through the Omega FD6001 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega FD6001 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega FD6001 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega FD6001 User manual - Online PDF
Advertisement
« Page 1 of 47 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega FD6001 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega FD6001. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MADE IN
User’s Guide
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
FD6001, FD6002, FD6003
Ultrasonic Flowmeter
with Totalization

Summary of the content on the page No. 2

® OMEGAnet Online Service Internet e-mail omega.com info@omega.com Servicing North America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: ® U.S.A. and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA ® Customer Service: 1-800-622-23

Summary of the content on the page No. 3

PART 1 - TABLE OF CONTENTS Description Pages Quick Start Installation 1.2-1.3 Operating Theory 1.4 Product Limitations 1.5 Model Number Matrix 1.6 Specifications 1.7 Transducer Installation 2.1-2.5 Pre-Installation Functional Test 3.1-3.2 Transmitter Installation 3.3-3.4 Power Source Jumper Settings 3.5 Electrical Connections 3.5-3.6 Power Up and Configuration 3.7 Keypad Operations 3.8-3.19 Tro

Summary of the content on the page No. 4

PART 1 - QUICK START This manual contains detailed operating instructions for all General aspects of the FD6000 instruments. The following condensed instructions are provided to assist the operator in getting the instrument started up and running as quickly as possible. This pertains to basic operation only. If specific instrument features are to be used or if the installer is unfamiliar with this type of instrument, refer to the appropriate section in the manual for complete details.

Summary of the content on the page No. 5

PART 1 - QUICK START 3. TRANSDUCER/POWER CONNECTIONS A. Do not attempt to add additional cable to the transducers. B. Refer to the DIAGRAMS in Figure 1.2 for proper power and transducer connections. Verify proper jumper selections are in place for the power source. See Figure 3.4. 4. INITIAL SETTINGS AND POWER UP IMPORTANT! In order to successfully complete the configuration of the FD6000 Series flow meter, the transducer must be mounted on a pipe which is full of a flowing liquid

Summary of the content on the page No. 6

PART 1 - GENERAL The FD6000 Series flowmeter is designed to General measure the flow of liquids and slurries in full-pipe closed systems. The transmitter is field configured to measure flow on a variety of pipes and liquids. The standard product is typically used on pipe sizes ranging from 1 - 120 inch [ 25 - 1524 mm ] pipe I.D. (With the small pipe transducer option, the pipe size range is 0.25 - 1 inch [ 6 - 25 mm]). A variety of liquid applications can be accommodated

Summary of the content on the page No. 7

PART 1 - GENERAL The flowmeter is typically used as a unidirectional Measuring Limits meter and is most accurate when the transducer is mounted in the orientation detailed in this manual. But, the meter will measure flow in both directions — although flow direction will not be indicated or totalized properly. The flowmeter will operate from signals returned from turbulence alone (such as installation directly at pump discharges or downstream from elbows and valves); however, it sho

Summary of the content on the page No. 8

PART 1 - GENERAL The FD6000 Series employs modular construction and provides electrical safety for the operator. The display face contains voltages no greater than 9 Vdc and any exposed metal work is electrically connected to Earth Ground. The display face swings open to allow access to user connections. The serial number and complete model number of Serial Number your meter is located on the inside of the transmitter front cover. Should technical assistance be required,

Summary of the content on the page No. 9

PART 1 - GENERAL (Std) 115 or 230 VAC 50/60 Hz ±10% and 12 VDC. (Opt) Power consumption less than 12 VA. 1-7

Summary of the content on the page No. 10

NOTES

Summary of the content on the page No. 11

PART 2 - TRANSDUCER INSTALLATION The following list outlines how to install the Transducer Mounting transducer for optimal performance, highest reliability Locations and greatest accuracy: 1. Select a transducer site at least 10 pipe diameters downstream from bends, or fittings and 5 pipe diameters upstream. A symmetrical flow pattern is necessary for accuracy and repeatability over the 1 Table 2.1 1 The system will provide repeatable measurements on piping systems that do not

Summary of the content on the page No. 12

PART 2 - TRANSDUCER INSTALLATION operating range of the meter. Down stream from pump or orifices, etc., locate at least 20 diameters. See Table 2.1 Transducer Cable 2. On horizontal pipe, select a position that is between 2 and 4 o’clock on the pipe, with 12 o’clock representing the top. If the transducer is to be mounted on a vertical pipe, select a section of pipe where the flow is moving from bottom to top (flow moving vertically down a pipe tends to FLOW cavitate and provide u

Summary of the content on the page No. 13

PART 2 - TRANSDUCER INSTALLATION permanently mounted. Under flowing liquid conditions, adequate signal is indicated when the Signal Strength indicates between 000125 and 000200 counts. Acoustic Couplant For proper operation, there cannot be air voids between the traducer face and pipe. The space must Types be filled with a material which is a good transmitter of sound energy such as: SILICONE GREASE: Dow Corning 111 R or comparable (-100 to +450 F.) The material must be suitable

Summary of the content on the page No. 14

PART 2 - TRANSDUCER INSTALLATION Installations requiring intrinsic safety should refer to Intrinsic Safety the Appendix drawings covering these applications. Installations 1. Pipe Preparation: For permanent silicone adhesive mounting, after determining the transducer location, some attention must be given to the pipe condition. Before the transducer head is bonded to the pipe surface, an area slightly larger than the flat surface to the transducer head (black rectangle) must be clean

Summary of the content on the page No. 15

PART 2 - TRANSDUCER INSTALLATION adhesive (Dow-732). Spread a bead of the adhesive on the flat surface of the transducer face, covering well. Now spread a bead to the prepared pipe surface and press the head lightly to the pipe. Let the adhesive flow enough to fill in all the area beneath the head. At the same time, clamp (clamp supplied) into place until the silicone has set up. Taping along the edges of the head will hold the adhesive in place. A pad of adhesive must be formed b

Summary of the content on the page No. 16

NOTES

Summary of the content on the page No. 17

PART 3 - PRE-INSTALLATION CHECKOUT After unpacking, it is recommended to save the shipping Unpacking carton and packing materials in case the instrument is stored or re-shipped. Inspect the equipment and carton for damage. If there is evidence of shipping damage, notify the carrier immediately. The FD6000 Series flowmeter can be checked for basic Functional Test functionality using the following Bench Test procedure. It is recommended that this operation be performed before permanent

Summary of the content on the page No. 18

PART 3 - PRE-INSTALLATION CHECKOUT forth with your thumb using moderate pressure. The cycle time should be 1-2 times per second. 8. Verify that signal strength increases with frequency of the rubbing. Typical increases will range from 20-30 counts. 9. Verify that signal strength decreases when rubbing ceases. Bench Test is Complete 3-2

Summary of the content on the page No. 19

PART 3 - TRANSMITTER INSTALLATION PART 2 - ELECTRICAL CONNECTIONS 1. Place the transmitter in a location that is: Transmitter Installation ♦ Where little vibration exist. ♦ Protected from falling corrosive fluids. ♦ Within ambient temperature limits - 22 to 122°F [-30 to 50°C] ♦ Out of direct sunlight. Direct sunlight may increase temperatures within the transmitter to above maximum limit. 2. Mounting: Refer to Figure 3.3 for enclosure and mounting dimension details. Ensure

Summary of the content on the page No. 20

PART 3 - TRANSMITTER INSTALLATION PART 2 - SERVICE AND MAINTENANCE 1.45 [36.8] 3.88 [98.5] FD-5000 Shown FIGURE 3.3 NOTE: The transducer cable carries low level signals. Important ! Do not attempt to add additional cable to the factory supplied transducer cable. 3-4


Alternative user manuals
# User manual Category Download
1 Omega FMA 1500 User manual Automobile Parts 0
2 Omega FD6002 User manual Automobile Parts 0
3 Omega FC-21 User manual Automobile Parts 1
4 Omega FD6003 User manual Automobile Parts 0
5 Omega FLOWMETER FL-1500A User manual Automobile Parts 1
6 Omega FL46300 User manual Automobile Parts 0
7 Omega FMA 1400 User manual Automobile Parts 0
8 Omega FMA 4000 User manual Automobile Parts 8
9 Omega FPDM1000 User manual Automobile Parts 0
10 Omega FTB-1000 User manual Automobile Parts 1
11 Omega FTB500 User manual Automobile Parts 0
12 Omega HHT21A User manual Automobile Parts 0
13 Omega HHT13 User manual Automobile Parts 9
14 Omega ETTE HHT-1500 User manual Automobile Parts 0
15 Omega ETTE HHT=1501 User manual Automobile Parts 2
16 Sony BP-GL95 User manual Automobile Parts 25
17 Sony BP-GL65 User manual Automobile Parts 2
18 Philips Epic 50PF9966 User manual Automobile Parts 3
19 Philips HTS3011 User manual Automobile Parts 2
20 Philips SDJ6040W User manual Automobile Parts 1