Samson 3222/5725 user manual

User manual for the device Samson 3222/5725

Device: Samson 3222/5725
Category: Automobile Parts
Manufacturer: Samson
Size: 0.44 MB
Added : 5/11/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Samson 3222/5725. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Samson 3222/5725.

For your convenience

If looking through the Samson 3222/5725 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Samson 3222/5725 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Samson 3222/5725 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Samson 3222/5725 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Samson 3222/5725 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Samson 3222/5725. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Electric Control Valves/
Controller with Electric Actuator
Type 3222/5724, Type 3222/5725 and Type 3222/5757
Type 3222/5757 Globe Valve mounted on
Type 3222/5725 Globe Valve mounted on
Controller with Electric Actuator
Controller with Electric Actuator
Mounting and
Operating Instructions
EB 5766 EN
Edition July 2008

Summary of the content on the page No. 2

Contents Contents Page 1 Design and principle of operation . . . . . . . . . . . . . . . . . . . 4 1.1 Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.1 Mounting position . . . . . . . . . . . .

Summary of the content on the page No. 3

General safety instructions General safety instructions The control valves may only be mounted, started up or serviced by fully  trained and qualified personnel, observing the accepted industry codes and practices. Make sure employees or third persons are not exposed to any danger. All safety instructions and warnings in these mounting and operating instructions, particularly those concerning assembly, start-up and maintenance, must be observed. The control valves fulfill the requirements of th

Summary of the content on the page No. 4

Design and principle of operation synchronous motor of the actuator and is 1 Design and principle of transferred over the connected gear as a operation positioning force onto the actuator stem. The control valves consist of a single-seated The Type 5757, Type 5724 and Type 5725 Type 3222 Globe Valve and either a are particularly suitable for DHW heating in Type 5757, Type 5757-7 or Type 5724 instantaneous heating systems and for fixed Controller with Electric Actuator or a Type set point control

Summary of the content on the page No. 5

Design and principle of operation 1 Valve body 2 Seat 3 Plug 4 Plug stem 5 Valve spring 6 Guide nipple 7 Balancing bellows 8 Balancing piston 10 Controller with electric actuator Type 3222/5724 Special version for temperatures up to 200 °C and Type 3222/5757 with plug balanced by a bellows Fig. 1 · Type 3222/5757 and Type 3222/5724 Electric Control Valves/Controller with Electric Actuator EB 5766 EN 5

Summary of the content on the page No. 6

Design and principle of operation 1.2 Technical data 1. Single-seated Type 3222 Globe Valve Nominal size DN 15 20 25 32 40 50 Version with threaded ends with flanges ������ as flanged body Thread size G ½¾ 1 ––– Version with female thread � � � – – – Nominal pressure PN 25 Seat/plug sealing Metal sealing for K ≤ 2.5 · Soft sealing for K ≥ 3.6 VS VS Rated travel mm 6 12 Rangeability 50 : 1 Leakage class acc. to DIN EN 1349 Class I (< 0.05 % of K coefficient) VS Version for water, oil and other li

Summary of the content on the page No. 7

Design and principle of operation Nominal size DN 15 20 25 32 40 50 Thread size G ½¾ 1 ––– K coefficients VS Version with female thread 3.6 5.7 7.2 – – – Version with male thread 4 6.3 8 16 20 25 0.1· 0.16 · 0.25 · 0.4 1.0 · 1.6 · 2.5 Reduced K coefficients VS ––– 5) 6) 0.63 · 1.0 · 1.6 · 2.5 4 · 3.6 Rated travel mm 6 12 1) Use an intermediate insulating piece for temperatures above 130 °C to protect the actuator 2) DN 15 to 25 with Type 5757 Actuator: Use an intermediate insulating piece for te

Summary of the content on the page No. 8

Design and principle of operation 2. Controllers with electric actuators 5757 5724 5725 Type 5757-7 5757 -10 -13 -20 -23 -10 -13 -20 -23 Nominal size DN 15 to 25 15 to 25 15 to 25 32 to 50 15 to 25 32 to 50 DHW heating in instantaneous heating systems, Scope of application Heating fixed set point control circuits in mechanical engineering Safety function Without Without With Rated travel mm 6 6 6 12 12 6 6 12 12 Transit time for rated travel s 20 35 18 70 35 35 18 70 35 Transit time upon fail-sa

Summary of the content on the page No. 9

Installation Install a strainer (SAMSON Type 2 NI)  2 Installation upstream of the control valve to prevent any sealing parts, weld spatter or other Caution! foreign matter carried along by the pro- Versions designed to handle temperatures cess medium from impairing the proper up to 200 °C must be fitted with the dark functioning of the valve, in particular, the gray graphite supplied with the valve. Do tight shut-off. not use the UDP seals available as accesso- The valve must be installed free

Summary of the content on the page No. 10

Attaching the actuator to the valve 3 Attaching the actuator to the 3.2 Type 5724/5725 Controller valve with Electric Actuator If the actuator has not already been Type 5724 mounted on the valve by the manufacturer 1. Turn the handwheel (see section 5.2) or when the original actuator on a valve is counterclockwise to retract the actuator to be replaced with a controller with electric stem as far as it will go. actuator, proceed as follows. 2. Place the actuator on the connection piece and secure

Summary of the content on the page No. 11

Electrical connections 4 Electrical connections 4.1 Type 5757-7 Controller with Electric Actuator Upon installing the electrical cables, Heating application: The controller with you are required to observe the regula- electric actuator requires a Pt 1000 temper- tions concerning electrical power in- ature sensor to be connected to measure the stallations according to DIN VDE 0100 flow temperature. Depending on the control as well as the regulations of your local task, an outdoor sensor or a room

Summary of the content on the page No. 12

Electrical connections The default setting (WE) is configured for an application with a Pt 1000 flow temperature VS RüS AS 230 V, 50 Hz sensor and water flowmeter (see Fig. 3). 4.3 Type 5724/5725 Controller * with Electric Actuator 1L 2 34 5 6 NL´ Domestic hot water heating in instanta- neous heating system: The electric wiring or ye rd br blk gr br bl blk options are the same as for the Type 5757 Controller with Electric Actuator, (see Fig. 2 · Wiring of Type 5757-7 (default) section 4.2). In a

Summary of the content on the page No. 13

Manual override Type 5725 5 Manual override The direction of action and travel can be Caution! read off the travel indication scale. The actuator is live! 5.1 Type 5757/-7 Controller 1. Undo the front cover and place a 4 mm with Electric Actuator hex screwdriver onto the red actuating shaft. Caution! 2. Turn the screwdriver counterclockwise Only activate the handwheel when the actu- only, and only until the travel final value ator is disconnected from the power supply. is reached at the maximum,

Summary of the content on the page No. 14

Operation 6 Operation The controllers with electric actuators are adapted to the required control task by configuration and parameterization per- formed in TROVIS-VIEW Operator Interface: Type 5757-7: TROVIS-VIEW  6661-1066 Type 5757: TROVIS-VIEW 6661-1062  Type 5724 and Type 5725: TROVIS-  VIEW 6661-1060 Note! Instructions on how to operate the TROVIS-VIEW Operator Interface as well as on the function and parameter settings are contained in the Mounting and Operating Instructions EB 5757-7 E

Summary of the content on the page No. 15

Maintenance 7 Maintenance The control valve is subject to natural wear. Depending on the conditions the valve is op- erated in, it needs to be checked at regular intervals. If leakage to the atmosphere occurs, remove the valve from the pipeline and replace the damaged parts. Warning! For maintenance work on the valve, make sure the relevant section of the pipeline is depressurized and, depending on the process medium, drained as well. For high medium temperatures, allow the section of the pipeli

Summary of the content on the page No. 16

Dimensions in mm and weights 8 Dimensions in mm and weights Nominal size DN 15 20 25 32 40 50 Thread size G ½¾ 1 ––– Pipe Ød 21.3 26.8 33.7 42 48 60 Thread size R G ¾ G 1G 1¼ G 1¾G 2G 2½ Width across flats SW 30 36 46 59 65 82 Length L 65 70 75 100 110 130 Length with welding ends L1 210 234 244 268 294 330 Height H2 45.5 94 Versions for temperatures up to 200 °C 140 185 and with intermediate insulating piece Height H3 30 55 Weight without actuator approx. kg 1.4 1.8 2.3 4.0 4.4 6.8 Versions for

Summary of the content on the page No. 17

Dimensions in mm and weights Weights of controllers with electric actuators Type 5757/-7 5724 5725 Weight without valve, approx. kg 0.7 1.1 1.3 Intermediate insulating piece Type 3222/5757(-7), only up to DN 25 Types 3222/5724 Types 3222/5725 Version with Flanged valve flanges body version Version with Version with female thread threaded ends Fig. 6 · Top: Valve dimensions (version with welding ends) · Bottom: Other valve versions EB 5766 EN 17

Summary of the content on the page No. 18

Appendix 9 Appendix 9.1 Wiring for Type 5757-7 (refer to EB 5757-7 EN) Note! The pump output L´ is non-floating (230 V~). Note: Terminals at point of installation, not included in scope of delivery blk black · bl blue · br brown · gr green · or orange · rd red · ye yellow Application with flow, return flow, and outdoor sensors as well as binary input to switch between VS RüS AS operating modes = Default setting (WE) 230 V, 50 Hz Functions WE Configuration Control w. reference variable 1 F01 - 1

Summary of the content on the page No. 19

Appendix Application with flow, return flow, and outdoor sensors as well as a potentiometer for adjusting the set points VS RüS AS 230 V, 50 Hz Functions WE Configuration Control w. reference variable 1 F01 - 1 Outdoor sensor 0 F02 - 0 Potentiometer/binary input 0 F05 - 1 Remote adjuster 0 F06 - 1 1L 2 34 5 6 NL´ BA as pump control output 0 F09 - 0 or ye rd br blk gr br bl blk Return flow sensor 1 F11 - 1 Application with flow, return flow, and room sensors with operating mode switchover and set

Summary of the content on the page No. 20

Appendix 9.2 Wiring for Type 5757 (refer to EB 5757 EN) Note: Terminals at point of installation, not included in scope of delivery 1) Water flowmeter 2) Flow switch blk black · bl blue · br brown · gr green · or orange · rd red · ye yellow Operation with Pt 1000 sensor and water flowmeter = Default setting (WE) Pt 1000 1) Functions WE Configuration 230V, 50Hz Hot water tapping recognition 1 F01 - 1 Water flowmeter 1 F02 - 1 5V GND L N Current input 0 F05 - 0 or ye rd br gr blk Operation with Pt


Alternative user manuals
# User manual Category Download
1 Samson 3222/5724 User manual Automobile Parts 0
2 Samson 3222/5757 User manual Automobile Parts 4
3 Samson Electri Actuator Type 3374 EB 8331-1 EN User manual Automobile Parts 56
4 Sony BP-GL95 User manual Automobile Parts 25
5 Sony BP-GL65 User manual Automobile Parts 2
6 Philips Epic 50PF9966 User manual Automobile Parts 3
7 Philips HTS3011 User manual Automobile Parts 2
8 Philips SDJ6040W User manual Automobile Parts 1
9 Philips SWA2151W User manual Automobile Parts 0
10 Philips Vortex Flow Meter F-2200 Series User manual Automobile Parts 3
11 A4 Tech. Sun StorageTekTM 4Gb FC Dual GbE HBA SG-XPCIE2FCGBE-E-Z User manual Automobile Parts 0
12 Aetna SATINELLE ICE HP6492 User manual Automobile Parts 0
13 Accel 140025 User manual Automobile Parts 15
14 Actron Cylinder Leakage Tester Kit 2509 User manual Automobile Parts 18
15 Actron 2501 User manual Automobile Parts 0