Summary of the content on the page No. 1 
                    
                        DINION capture 5000/7000
VER Series
en Installation Manual                                                                                                                                                                                                                                                                                                                                                                                                                                                          
                    
                    Summary of the content on the page No. 2 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Summary of the content on the page No. 3 
                    
                        DINION capture 5000/7000 Table of Contents | en 3 Table of Contents 1Safety 5 1.1 Safety precautions 5 1.2 Important safety instructions 6 1.3 Important notices 9 1.4 FCC & ICES compliance 13 1.5 Bosch notices 15 2 Description 16 2.1 Parts List 16 3 Installing the DINION capture 17 3.1 Determining the Range 17 3.2 Determining the Angle 18 3.3 Mounting the DINION capture 20 3.4 Preparing the Wiring 23 3.4.1 Power Input Connections 23 3.4.2 Video Connections 23 3.5 Making the Connections 24 3.6 Au
                    
                    Summary of the content on the page No. 4 
                    
                        4 en | Table of Contents DINION capture 5000/7000 4.5.6 Color submenu  (Overview Camera - DINION capture 7000 only) 43 4.5.7 VMD submenu 44 4.6 Install menu structure 45 4.6.1 Language submenu 46 4.6.2 Lens Wizard submenu 46 4.6.3 Alarm I/O submenu 47 4.6.4 Connections submenu 48 4.6.5 Test signal submenu 49 4.6.6 Camera ID submenu 50 4.6.7 Privacy masking submenu 51 4.6.8 Defaults submenu 51 A Dimensional Drawings 52  | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.             
                    
                    Summary of the content on the page No. 5 
                    
                        DINION capture 5000/7000 Safety | en 5 1Safety 1.1 Safety precautions DANGER!  High risk: This symbol indicates an imminently hazardous  situation such as "Dangerous Voltage" inside the product. If not avoided, this will result in an electrical shock, serious  bodily injury, or death. WARNING!  Medium risk: Indicates a potentially hazardous situation. If not avoided, this could result in minor or moderate bodily  injury. CAUTION!  Low risk: Indicates a potentially hazardous situation. If not avo
                    
                    Summary of the content on the page No. 6 
                    
                        6 en | Safety DINION capture 5000/7000 1.2 Important safety instructions Read, follow, and retain for future reference all of the following  safety instructions. Heed all warnings on the unit and in the  operating instructions before operating the unit. 1. Cleaning - Unplug the unit from the outlet before cleaning.  Follow any instructions provided with the unit. Generally,  using a dry cloth for cleaning is sufficient but a moist, fluff- free cloth or leather shammy may also be used. Do not use
                    
                    Summary of the content on the page No. 7 
                    
                        DINION capture 5000/7000 Safety | en 7 8. Power disconnect - Units have power supplied to the unit  whenever the power cord is inserted into the power  source. The power cord plug is the main power disconnect  device for switching off the voltage for all units. 9. Power sources - Operate the unit only from the type of  power source indicated on the label. Before proceeding,  be sure to disconnect the power from the cable to be  installed into the unit. – For external power supplied units, use on
                    
                    Summary of the content on the page No. 8 
                    
                        8 en | Safety DINION capture 5000/7000 12. Replacement parts - Be sure the service technician uses  replacement parts specified by the manufacturer, or that  have the same characteristics as the original parts.  Unauthorized substitutions may cause fire, electrical  shock, or other hazards. 13. Safety check - Safety checks should be performed upon  completion of service or repairs to the unit to ensure  proper operating condition. 14. Installation - Install in accordance with the manufacturer's 
                    
                    Summary of the content on the page No. 9 
                    
                        DINION capture 5000/7000 Safety | en 9 1.3 Important notices Accessories - Do not place this unit on an unstable stand,  tripod, bracket, or mount. The unit may fall and cause serious  injury and/or serious damage to the unit. Use only with the  cart, stand, tripod, bracket, or table specified by the  manufacturer. When a cart is used, use caution and care when  moving the cart/apparatus combination to avoid injury from  tip-over. Quick stops, excessive force, or uneven surfaces may  cause the c
                    
                    Summary of the content on the page No. 10 
                    
                        10 en | Safety DINION capture 5000/7000 The Exposure Hazard Value for the product (ratio of the  Exposure level to the Exposure limit) is up to 1.8 at a test  distance of 200 mm or 8 inches. The Hazard Distance (distance  beyond which the product falls into the exempt/safe group) is  at most 350 mm or 14 inches. Note that typical operating  distances for license plate capture (3.8 m or 12.5 feet and  greater) are much greater than the Hazard Distance. When servicing the unit, physically disconne
                    
                    Summary of the content on the page No. 11 
                    
                        DINION capture 5000/7000 Safety | en 11 Environmental statement - Bosch has a strong commitment  towards the environment. This unit has been designed to  respect the environment as much as possible. Electrostatic-sensitive device - Use proper CMOS/MOS-FET  handling precautions to avoid electrostatic discharge. NOTE: Wear required grounded wrist straps and observe proper  ESD safety precautions when handling the electrostatic- sensitive printed circuit boards. Fuse rating - For protection of the 
                    
                    Summary of the content on the page No. 12 
                    
                        12 en | Safety DINION capture 5000/7000 11-30 VDC / 24 VAC power source: This device is intended to  operate with a limited power source; this power source must  comply with EN60950. The device is designed to operate at  either 11-30 VDC or 24 VAC (if PoE is not available). User  supplied wiring must be in compliance with electrical codes  (Class 2 power levels). If 24 VAC is used, do not ground the  24 VAC supply at the terminals or at the device's power supply  terminals. Connections: The unit
                    
                    Summary of the content on the page No. 13 
                    
                        DINION capture 5000/7000 Safety | en 13 1.4 FCC & ICES compliance FCC & ICES Information (U.S.A. and Canadian Models Only) This device complies with part 15 of the FCC Rules. Operation is  subject to the following conditions: – this device may not cause harmful interference, and – this device must accept any interference received,  including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply  with the limits for a Class A digital device, pur
                    
                    Summary of the content on the page No. 14 
                    
                        14 en | Safety DINION capture 5000/7000 – cet appareil ne peut pas provoquer d'interférence nuisible  et – cet appareil doit pouvoir tolérer toutes les interférences  auxquelles il est soumit, y compris les interférences qui  pourraient influer sur son bon fonctionnement. AVERTISSEMENT: Suite à différents tests, cet appareil s’est  révélé conforme aux exigences imposées aux appareils  numériques de Classe A en vertu de la section 15 du règlement  de la Commission fédérale des communications des 
                    
                    Summary of the content on the page No. 15 
                    
                        DINION capture 5000/7000 Safety | en 15 1.5 Bosch notices Video loss Video loss is inherent to digital video recording; therefore,  Bosch Security Systems cannot be held liable for any damage  that results from missing video information. To minimize the  risk of lost digital information, Bosch Security Systems  recommends multiple, redundant recording systems, and a  procedure to back up all analog and digital information. Copyright This manual is the intellectual property of Bosch Security  Sys
                    
                    Summary of the content on the page No. 16 
                    
                        16 en | Description DINION capture 5000/7000 2 Description The DINION capture is a specialty camera designed to capture  consistent, high-quality images of vehicle license plates.  Available in IP and analog versions, it is ideal for monitoring  parking lots, public areas, and for controlling vehicle access. The DINION capture overcomes the problems encountered  when using conventional surveillance cameras in vehicle  identification and automatic license plate recognition  applications. The Nigh
                    
                    Summary of the content on the page No. 17 
                    
                        DINION capture 5000/7000 Installing the DINION capture | en 17 3 Installing the DINION capture This section provides instructions for mounting and wiring the  DINION capture. CAUTION!  The selected mounting location should not place the camera in  a situation where its environmental specifications could be  exceeded. Ensure the selected location is protected from falling objects,  accidental contact with moving objects, and unintentional  interference from personnel. Follow all applicable buildi
                    
                    Summary of the content on the page No. 18 
                    
                        18 en | Installing the DINION capture DINION capture 5000/7000 Model Capture Optimal HFOV VFOV Range Distance VER-x2R1-1 3.8–6.4 m 4.9 m 31.9° 24.2° (12.5–21.0 ft) (16.0 ft) VER-x2R1-2 23.0° 17.3° VER-x2R2-1 5.5–9.1 m 7.1 m 22.3° 16.8° (18–30 ft) (23.1 ft) VER-x2R2-2 16.0° 12.0° VER-x2R3-1 7.9–13.7 m 10.2 m 15.6° 11.8° (26–45 ft) (33.5 ft) VER-x2R3-2 11.1° 8.3° VER-x2R4-1 11.3–19.5 m 14.8 m 10.8° 8.1° (37–64 ft) (48.4 ft) VER-x2R4-2 7.7° 5.8° VER-x2R5-1 16.5–28.0 m 21.3 m 7.5° 5.6° (54–92 ft) (7
                    
                    Summary of the content on the page No. 19 
                    
                        DINION capture 5000/7000 Installing the DINION capture | en 19 Figure 3.1 Recommended Vertical and Horizontal Mounting Angle 1 DINION capture 2 Capture Range 3 Vertical Mounting Angle 4 Horizontal Mounting Angle If the maximum range is exceeded, then the letters become  smaller and more difficult to read. At the maximum range and  angle the width of the number plate covers approximately 12%  of the width of the screen.  NOTICE!  The Capture Range is the distance from the license plate  camera to
                    
                    Summary of the content on the page No. 20 
                    
                        20 en | Installing the DINION capture DINION capture 5000/7000 3.3 Mounting the DINION capture CAUTION!  Installation should only be performed by a qualified service  professional in accordance with the National Electrical Code or  applicable local codes. For a secure mounting installation, bolts should extend through  the mounting surface and be secured with nuts, washers, and  lock washers on the opposite side. If studs are used, they  should be anchored in concrete or welded to a steel backer