DMP Electronics Inc.LT-0229 (5 97) user manual

User manual for the device DMP Electronics Inc.LT-0229 (5 97)

Device: DMP Electronics Inc.LT-0229 (5 97)
Category: Home Security System
Manufacturer: DMP Electronics
Size: 1.11 MB
Added : 5/9/2013
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for DMP Electronics Inc.LT-0229 (5 97). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with DMP Electronics Inc.LT-0229 (5 97).

For your convenience

If looking through the DMP Electronics Inc.LT-0229 (5 97) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual DMP Electronics Inc.LT-0229 (5 97) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual DMP Electronics Inc.LT-0229 (5 97) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
DMP Electronics Inc.LT-0229 (5 97) User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual DMP Electronics Inc.LT-0229 (5 97) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to DMP Electronics Inc.LT-0229 (5 97). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

XR10/XR20 Command Processor Panels
Installation Guide
10/26 Zone Burglary/Fire/Access Control Panels with Built-in Communicator
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
LT-0229 (5/97)
Downloaded from: http://www.guardianalarms.net

Summary of the content on the page No. 2

MODEL XR10/XR20 COMMAND PROCESSOR INSTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed and used properly in strict accordance with the manufacturer's instructions, may cause interference with radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specification in Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection ag

Summary of the content on the page No. 3

TABLE OF CONTENTS Section Panel Specifications Power supply........................................................................................ 1.1 Communication .................................................................................... 1.2 Panel zones ......................................................................................... 1.3 Keypads ............................................................................................... 1.4 Outputs .......................

Summary of the content on the page No. 4

TABLE OF CONTENTS Section Reset Jumpers J16 Description ......................................................................................... 14.1 Universal UL Burglary Specifications Introduction ........................................................................................ 15.1 Wiring ................................................................................................. 15.2 Police station phone numbers ............................................................ 15.3

Summary of the content on the page No. 5

Introduction Panel Specifications 1.1 Power supply Transformer Input: 16.5 VAC 40VA (Models 320 wire-in or 321 plug-in) Standby Battery: 12 VDC 6.5Ah (40VA transformer charges up to 2 batteries) Auxiliary Output: 12 VDC at 500mA Bell Output: 12 VDC at 1.5 Amps Smoke Detector Output: 12 VDC at 100mA All circuits inherent power limited 1.2 Communication Built-in SDLC Digital Dialer communication to DMP Model SCS-1 Receivers Built-in 4-2 communication to non-DMP receivers. Built-in M2E (Radionics

Summary of the content on the page No. 6

Introduction 2.3 Before you begin Before installing the XR10/XR20, we recommend you read through the entire contents of this guide. Familiarize yourself with the features of the panel and the key points to remember during the installation. Be sure to read and understand all of the caution statements printed in bold italics. In addition to this installation guide, you should also read through and familiarize yourself with these other product documents: • XR10 Programming Guide (LT-0230) • XR20 P

Summary of the content on the page No. 7

Introduction System Components 3.1 Description The DMP XR10/XR20 system is made up of an alarm panel with built in communicator, an enclosure, a 16.5 VAC transformer, and a 12 VDC 6.5 Ah battery. You can add up to four Security Command keypads to the system and can also connect auxiliary devices to the panel's open collector outputs to expand the basic system. Combined current requirements of additional modules may require an auxiliary power supply. Refer to section 6.6 in this guide when calcul

Summary of the content on the page No. 8

Installation Installation 4.1 Mounting the enclosure The metal enclosure for the XR10/XR20 must be mounted in a secure, dry place to protect the panel from damage due to tampering or the elements. It is not necessary to remove the XR10/XR20 PC board when installing the enclosure. Dual 1/2" and 3/4" Conduit Knockouts J16 J11 1 Reset Jumper 2 3 4 J4 Phone Jack Connector U11 1 23 4 56 78 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 AC AC +B -B BELL GND RED YEL GRN BLK SMK Z1 GND Z2 Z3 GND Z

Summary of the content on the page No. 9

Installation 4.2 Mounting keypads Security Command keypads have removable covers that allow you to easily mount the base with keypad circuit board to a wall or other flat surface using the screw holes provided on each corner. Before mounting the base, connect the keypad wire harness leads to the 4-wire keypad data bus cable from the panel. Next, attach the keypad wire harness connector to the pin connector on the keypad circuit board, mount the base, and install the keypad cover making sure all

Summary of the content on the page No. 10

Installation 6.4 Discharge/recharge The XR10/XR20 battery charging circuit float charges at 13.9 VDC at a maximum current of 1.2 Amps using a 40VA transformer. The total current available is reduced by the combined auxiliary current draw from terminals 7, 11, and 25. The various battery voltage levels are listed below: Battery Trouble: Below 11.9 VDC Battery Restored: Above 12.6 VDC 6.5 Battery supervision The XR10/XR20 tests the battery once every hour when AC power is present. The test lasts f

Summary of the content on the page No. 11

Installation Bell Output 7.1 Terminals 5 and 6 Nominal 12 VDC is supplied by terminal 5 on the panel to power alarm bells or horns. The output is rated for a maximum output of 1.5 Amps. This output can be steady or pulsed depending upon the Bell Action specified in Output Options. Terminal 6 is the ground reference for the bell circuit. Keypad Data Bus 8.1 Description Terminals 7, 8, 9, and 10 of the XR10/XR20 panel are designated as the keypad data bus. In addition to keypads, the XR20 allows t

Summary of the content on the page No. 12

Installation 10.2 Operational parameters Each burglary protection zone detects three conditions: open, normal, and short. The parameters for each are listed below: Condition Resistance on zone Voltage on right terminal Open over 1300 ohms over 2.0 VDC Normal 600 to 1300 ohms 1.2 to 2.0 VDC Short under 600 ohms under 1.2 VDC 1K 1K 1K NORMALLY CLOSED CONTACTS NORMALLY OPEN CONTACTS COMBINATION: NORMALLY OPEN AND NORMALLY CLOSED CONTACTS Figure 3: Protection zone contact wiring 10.3 Zon

Summary of the content on the page No. 13

Installation Annunciator Outputs 12.1 Description The four annunciator outputs can be programmed to indicate the activity of the panel's zones or conditions occurring on the system. Annunciator outputs do not provide a voltage but instead switch to ground voltage from another source. The outputs can respond to any of the conditions listed below: 1) Activation by zone condition: Steady, Pulse, Momentary, or Follower 2) Manually from the Security Command keypad 3) Communication failure 4) Arme

Summary of the content on the page No. 14

Installation 13.4 Ground start To configure the XR10/XR20 for ground start operation, you must install the appropriate ground start module and program one of the panel's available annunciator outputs for Ground Start operation. Refer to the XR10/XR20 Programming Guide for complete programming information. Reset Jumpers J16 14.1 Description There are two reset jumpers located at the top right of the panel's circuit board labeled RESET. Momentarily shorting these jumpers allows you to reset the mi

Summary of the content on the page No. 15

Installation UNIVERSAL UL BURGLARY SPECIFICATIONS 15.1 Introduction The programming and installation specifications contained in this section must be completed when installing the XR10/XR20 panel in accordance with any of the UL burglary standards. Additional specifications may be required by a particular standard. 15.2 Wiring All wiring must be in accordance with NEC, ANSI/NFPA 70, UL 681, and UL 611 for all burglary installations. 15.3 Police station phone numbers The digital dialer telephon

Summary of the content on the page No. 16

Installation UL 1610 and 1076 SPECIFICATIONS Central-Station and Proprietary Burglar-Alarm Units 17.1 Opening/Closing reports The Opening/Closing Reports option must be programmed as YES. See section 5.2 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305). 17.2 Automatic bell test This option must be programmed as YES. See section 7.3 of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305). 17.3 Proprietary dialer The Model XR10/XR20 provides Grade

Summary of the content on the page No. 17

Installation 19.6 Mercantile Safe and Vault When the DMP Model 349A housing is used, the XR10/XR20 provides operation as a mercantile safe and vault alarm. Bell Supervision and wiring must be in accordance with UL 681. If the Model XR10/XR20 is mounted outside the safe or vault, tamper protection and the Sentrol Model 5402 or Potter EVD listed vibration detectors should be used. The XR10/XR20 does not provide operation as a Bank Safe and vault alarm. 19.7 Line security for Police Connect Basic l

Summary of the content on the page No. 18

Troubleshooting CALIFORNIA STATE FIRE MARSHAL SPECIFICATIONS 22.1 Bell output definition The bell output of the Model XR10/XR20 must be programmed to operate steady on burglary alarms and pulsed on fire alarms. See sections 7.4A and 7.4B of the XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305). Troubleshooting Section 23.1 Description This section of the XR10/XR20 Installation Guide provides troubleshooting information for use when installing or servicing an XR10/XR20 system


Alternative user manuals
# User manual Category Download
1 DMP Electronics Inc.Command Processor Panel User manual Home Security System 1
2 DMP Electronics DMP Command Processor Panel XR500 User manual Home Security System 97
3 DMP Electronics Inc.XR10 User manual Home Security System 0
4 DMP Electronics XR6 User manual Home Security System 3
5 DMP Electronics XR10 User manual Home Security System 1
6 DMP Electronics Security Control Receiver SCS-1R User manual Home Security System 20
7 3Com 1000BASE-T-GBIC User manual Home Security System 0
8 Sony BRCSDP12 User manual Home Security System 3
9 3Com TECHD-0000000122 User manual Home Security System 1
10 Sony SSC-M354 User manual Home Security System 3
11 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9
12 Sony SNC-RX SNC-CS50 User manual Home Security System 4
13 Sony SSC-M183/M183CE/M188CE SSC-M383/M383CE/M388CE User manual Home Security System 10
14 Sony CD-7226 User manual Home Security System 1
15 Sony Ssc-M383 User manual Home Security System 6