Finisar AN-2030 user manual

User manual for the device Finisar AN-2030

Device: Finisar AN-2030
Category: Home Security System
Manufacturer: Finisar
Size: 0.24 MB
Added : 8/16/2014
Number of pages: 35
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Finisar AN-2030. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Finisar AN-2030.

For your convenience

If looking through the Finisar AN-2030 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Finisar AN-2030 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Finisar AN-2030 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Finisar AN-2030 User manual - Online PDF
Advertisement
« Page 1 of 35 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Finisar AN-2030 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Finisar AN-2030. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r
1
2 Application Note AN-2030
3 Digital Diagnostic Monitoring Interface
4 for SFP Optical Transceivers
5
6 1. Scope and Overview
7
8 This document defines an enhanced digital diagnostic monitoring interface available in
9 Finisar SFP and GBIC optical transceivers. The interface allows real time access to
10 device operating parameters, and it includes a sophisticated system of alarm and
11 war

Summary of the content on the page No. 2

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 2 3. Enhanced Digital Diagnostic Interface Definition 3 4 Overview 5 6 The enhanced digital diagnostic interface is a superset of the MOD-DEF interface 7 defined in the SFP MSA document dated September 14, 2000. The 2-wire interface pin 8 definitions, hardware, and timing are clearly defined there, as well as in Section 4 9 below. This section describes an extension to the memory map defined

Summary of the content on the page No. 3

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 2 Figure 3.1: Digital Diagnostic Memory Map 3 2 wire address 1010000X (A0h) 2 wire address 1010001X (A2h) 4 5 0 0 6 Alarm and Warning 7 Thresholds (56 bytes) Serial ID Defined by 8 55 SFP MSA (96 bytes) 9 Cal Constants 10 (40 bytes) 95 11 95 Real Time Diagnostic 12 Vendor Specific 13 Interface (24 bytes) (32 bytes) 14 119

Summary of the content on the page No. 4

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 Table 3.1 Serial ID: Data Fields – Address A0 Size Data Name of (Bytes) Description of Field Address Field BASE ID FIELDS 0 1 Identifier Type of serial transceiver (see table 3.2) 1 1 Ext. Identifier Extended identifier of type of serial transceiver 2 1 Connector Code for connector type (see table 3.3) 3-10 8 Transceiver Code for electronic compatibility or optical compatibility (see table

Summary of the content on the page No. 5

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 Identifier 2 The identifier value specifies the physical device described by the serial information. 3 This value shall be included in the serial data. The defined identifier values are shown in 4 table 3.2. Finisar SFP modules have this byte set to 03h. Finisar GBIC modules have 5 this byte set to 01h. 6 TABLE 3.2: Identifier values 7 Value Description of physical device 00h Unknown or unsp

Summary of the content on the page No. 6

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 2 TABLE 3.3: Connector values Value Description of connector 00h Unknown or unspecified SC 01h Fibre Channel Style 1 copper connector 02h Fibre Channel Style 2 copper connector 03h BNC/TNC 04h Fibre Channel coaxial headers 05h 06h FiberJack 07h LC 08h MT-RJ 09h MU 0Ah SG 0Bh Optical pigtail 0C-1Fh Reserved 20h HSSDC II 21h Copper Pigtail 22h-7Fh Reserved 80-FFh Vendor specific 3

Summary of the content on the page No. 7

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 Transceiver 2 The following bit significant indicators define the electronic or optical interfaces that are 3 supported by the transceiver. At least one bit shall be set in this field. For Fibre Channel 4 transceivers, the Fibre Channel speed, transmission media, transmitter technology, and 5 distance capability shall all be indicated. The SONET Compliance Codes are described 6 in more detail in tab

Summary of the content on the page No. 8

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 The SONET compliance code bits allow the host to determine with which specifications 2 a SONET transceiver complies. For each bit rate defined in Table 3.5 (OC-3, OC-12, 3 OC-48), SONET specifies short reach (SR), intermediate reach (IR), and long reach 4 (LR) requirements. For each of the three bit rates, a single short reach (SR) 5 specification is defined. Two variations of intermediate reach (I

Summary of the content on the page No. 9

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 BR, nominal 2 The nominal bit rate (BR, nominal) is specified in units of 100 Megabits per second, 3 rounded off to the nearest 100 Megabits per second. The bit rate includes those bits 4 necessary to encode and delimit the signal as well as those bits carrying data 5 information. A value of 0 indicates that the bit rate is not specified and must be 6 determined from the transceiver technology. The a

Summary of the content on the page No. 10

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 transceiver technology. It is common for the transceiver to support both 50 micron and 2 62.5 micron fiber. 3 4 Length (Copper) 5 This value specifies the minimum link length that is supported by the transceiver while 6 operating in compliance with the applicable standards using copper cable. The value is 7 in units of 1 meter. A value of 255 means that the transceiver supports a link length 8 gre

Summary of the content on the page No. 11

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 Vendor Rev 2 The vendor revision number (vendor rev) is a 4-byte field that contains ASCII 3 characters, left-aligned and padded on the right with ASCII spaces (20h), defining the 4 vendor’s product revision number. A value of all zero in the 4-byte field indicates that 5 the vendor rev is unspecified. All legacy Finisar transceivers contain zero in all 4 bytes 6 or ASCII space (20h) in all four byt

Summary of the content on the page No. 12

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 Options 2 The bits in the option field shall specify the options implemented in the transceiver as 3 described in table 3.6. StandardFinisar SFP transceivers do not implement TX_FAULT 4 or RATE_SELECT, so byte 65 set to 00010010b. 5 6 Table 3.6: Option values Data Bit Description of option Address 64 7-0 Reserved 65 7-6 Reserved 65 5 Indicates if RATE_SELECT is implemented. Finisar does not

Summary of the content on the page No. 13

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 2 Date Code 3 The date code is an 8-byte field that contains the vendor’s date code in ASCII 4 characters. The date code is mandatory. The date code shall be in the format specified 5 by table 3.7. 6 Table 3.7: Date Code 7 Data Description of field Address ASCII code, two low order digits of year. (00 = 2000). 84-85 ASCII code, digits of month (01 = Jan through 12 = 86-87 Dec) ASCII code,

Summary of the content on the page No. 14

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 Table 3.8: Diagnostic Monitoring Type Data Address Bits Description 92 7 Reserved for legacy diagnostic implementations. Must be ‘0’ for compilance with this document. 92 6 Digital diagnostic monitoring implemented (described in this document). Must be ‘1’ for compliance with this document. 92 5 Internally Calibrated 92 4 Externally Calibrated 92 3 Received power measurement type 0 = OMA,

Summary of the content on the page No. 15

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 Enhanced Options 2 “Enhanced Options” is a 1 byte field with 8 single bit indicators which describe the 3 optional digital diagnostic features implemented in the transceiver. Since transceivers 4 will not necessarily implement all optional features described in this document, the 5 “Enhanced Options” bit field allows the host system to determine which functions are 6 available over the 2 wire serial

Summary of the content on the page No. 16

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 2 Table 3.10: I/O Timing for Soft Control & Status Functions Parameter Symbol Min Max Units Conditions 1 TX_DISABLE assert time t_off 100 ms Time from TX_DISABLE bit set until optical output falls below 10% of nominal TX_DISABLE deassert time t_on 100 ms Time from TX_DISABLE bit 1 cleared until optical output rises above 90% of nominal Time to initialize, including t_init 300 ms From power o

Summary of the content on the page No. 17

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 2 Diagnostics 3 2 wire serial bus address 1010001X (A2h) is used to access measurements of 4 transceiver temperature, internally measured supply voltage, TX bias current, TX output 5 power, received optical power, and two additional quantities to be defined in the future. 6 The values are interpreted differently depending upon the option bits set at address 92. 7 If bit 5 “internally calibrated” i

Summary of the content on the page No. 18

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 calibrated to absolute units using the most representative fiber output type. 2 Accuracy is ±3dB. Data is not valid when the transmitter is disabled. 3 5) Measured RX received average optical power in mW. Represented as a 16 bit 4 unsigned integer with the power defined as the full 16 bit value (0 – 65535) with LSB 5 equal to 0.1 µW, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm). 6

Summary of the content on the page No. 19

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 External Calibration 2 Measurements are raw A/D values and must be converted to real units using calibration 3 constants stored in EEPROM locations 56 – 95 at 2 wire serial bus address A2h (see 4 Table 3.15). Calibration is valid over specified device operating temperature and 5 voltage. Alarm and warning threshold values should be interpreted in the same manner 6 as real time 16 bit data. 7 1) In

Summary of the content on the page No. 20

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers F i n i s a r 1 5) Measured received optical power. Received power, RX_PWR, is given in µW by 2 the following equation: 4 3 Rx_PWR (µW) = Rx_PWR(4) * Rx_PWR (16 bit unsigned integer) + AD 3 2 4 Rx_PWR(3)*Rx_PWR (16 bit unsigned integer)+ Rx_PWR(2)*Rx_PWR (16 bit AD AD 5 unsigned integer)+ Rx_PWR(1) *Rx_PWR (16 bit unsigned integer) + Rx_PWR(0) AD 6 The result is in units of 0.1µW yielding a total range o


Alternative user manuals
# User manual Category Download
1 3Com 1000BASE-T-GBIC User manual Home Security System 0
2 Sony BRCSDP12 User manual Home Security System 3
3 3Com TECHD-0000000122 User manual Home Security System 1
4 Sony SSC-M354 User manual Home Security System 3
5 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9
6 Sony SNC-RX SNC-CS50 User manual Home Security System 4
7 Sony SSC-M183/M183CE/M188CE SSC-M383/M383CE/M388CE User manual Home Security System 10
8 Sony CD-7226 User manual Home Security System 1
9 Sony Ssc-M383 User manual Home Security System 6
10 Sony Snc Df50n User manual Home Security System 1
11 Sony SNC-RX SNC-RZ50 User manual Home Security System 20
12 Sony BLUETOOTH MEX-BT2500 User manual Home Security System 10
13 4XEM IPCAMW40 User manual Home Security System 1
14 ABC Office 24501 User manual Home Security System 0
15 ABC Office KT7060 User manual Home Security System 0