Honeywell VISTA-10SE user manual

User manual for the device Honeywell VISTA-10SE

Device: Honeywell VISTA-10SE
Category: Home Security System
Manufacturer: Honeywell
Size: 0.2 MB
Added : 5/26/2014
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell VISTA-10SE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell VISTA-10SE.

For your convenience

If looking through the Honeywell VISTA-10SE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell VISTA-10SE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell VISTA-10SE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell VISTA-10SE User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell VISTA-10SE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell VISTA-10SE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Security
Security
System
System
User's Manual
VIA-30PSE, VISTA-10SE
®
N7229V2 Rev B. 1/97

Summary of the content on the page No. 2

TABLE OF CONTENTS SYSTEM OVERVIEW...................................................................................... 3 ARMING ALL PROTECTION (MAXIMUM)............................................. 19 General.......................................................................................................... 3 DISARMING THE SYSTEM AND SILENCING ALARMS 20 ..................... Zones.............................................................................................................

Summary of the content on the page No. 3

SYSTEM OVERVIEW General Congratulations on your ownership of an Ademco Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today, including microcomputer technology to monitor all system status. Ademco is the world's largest manufacturer of security systems and millions of premises are protected by Ademco systems. Basically, this system offers you three forms of protection: burglary, fire and emergency. Your system may consi

Summary of the content on the page No. 4

SYSTEM OVERVIEW Alarms When an alarm occurs, both the keypad and external sounders will sound, and a message at the keypad will identify the zone(s) causing the alarm. In addition, if your system is connected to a central monitoring station, an alarm message will be sent. To stop the alarm sounding, you simply disarm the system. Fire Protection When an alarm or trouble condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm or tr

Summary of the content on the page No. 5

ABOUT THE KEYPADS General Your keypads allow you to control all system functions. The keypads feature a telephone style (digital) keys and a Liquid Crystal Display (LCD) which shows the nature and location of all occurrences. The keypads feature a built-in sounder which emits alarm sounds during alarm and trouble conditions, and produces warning tones during entry and exit, delay periods (if so- programmed). The sounder also provides acknowledgment tones when keys are pressed, and confirmation t

Summary of the content on the page No. 6

ABOUT THE KEYPADS Fixed-Word Keypad Displays AWAY All burglary zones, interior & perimeter, are armed. NO AC STAY Perimeter burglary zones, such as windows and AWAY CHIME STAY doors are armed. 00 00 00 BAT INSTANT ALARM INSTANT Perimeter burglary zones armed and entry delay is BYPASS CHECK turned off. FIRE NOT READY BYPASS One or more burglary protection zones have been STYLE A bypassed. NOT READY Appears when burglary portion of the system is not ready for arming (due to one or more open NO AC

Summary of the content on the page No. 7

ABOUT THE KEYPADS KEYPADS WITH FLIP-DOWN KEY COVERS ARE SHOWN WITH COVER REMOVED ARMED READY OFF AWAY STAY 2 1 3 MAX TEST BYPASS 4 5 6 INSTANT CODE CHIME 7 89 READY 0 # * PANIC 6139 ALPHA KEYPAD AWAY NO AC NO AC AWAY ARMED STAY ARMED CHIME 00 BYPASS INSTANT BAT NOT READY ALARM BYPASS ALARM STAY CHIME BAT CHECK READY READY CHECK INSTANT FIRE NOT READY FIRE OFF AWAY STAY OFF AWAY STAY 2 A 1 3 12 3 MAX TEST BYPASS MAX TEST BYPASS 4 5 6 B 45 6 INSTANT CODE CHIME INSTANT CODE CHIME 7 89 C 7 8 9 R

Summary of the content on the page No. 8

FUNCTIONS OF THE KEYPAD 1 DISPLAY WINDOW. Alpha Keypads: A 2-line, 32- 10. CHIME KEY: Turns CHIME mode on and off. When on, the character Liquid Crystal Display (LCD). Displays protection opening of windows or doors while the system is disarmed point identification, system status, and messages. Fixed- will sound 3 beeps at the keypad(s). Word Keypads: Display protection zone ID and system    11.    READY KEY: Displays all open protection zones. status messages using pre-designated words (see pa

Summary of the content on the page No. 9

1 5 2 3 4 6 ARMED READY OFF 7 A OFF AWAY AWAY STAY STAY A 1 2 3 1 2 3 15 MAX TEST BYPASS 9 B MAX TEST BYPASS 4 5 6 14 B 4 5 6 C INSTANT INSTANT CODE CODE CHIME CHIME SHOWN WITH 10 7 8 9 C 7 89 FLIP-DOWN 16 KEY COVER READY D READY REMOVED 0 # 0 # * 12 * PANIC 17 8 11 13 TYPICAL ALPHA KEYPAD Fixed-Word Keypads are functionally similar, except for screen displays (see page 6). IMPORTANT!: When entering codes and commands, sequential key depressions must be made within 2 seconds of one another. If 2

Summary of the content on the page No. 10

SECURITY CODES General At the time of installation, your installer programmed a personal four-digit Master code, known only to you and yours. This code is used to perform most system functions, including arming and disarming of the system. As an additional safety feature, temporary User Codes can be assigned for use by those not having a need to know the Master code. Note that the Master code remains in effect even when other user codes are assigned. IMPORTANT! When performing any of the proced

Summary of the content on the page No. 11

SECURITY CODES (Continued) Duress Code To program a Duress code: (Continued) Enter your Master Code + 8 + 8 + [desired 4-digit duress code]. The keypad will beep once. Note: The Duress code must differ from the Master Code or any other User’s Code. To change the Duress code: Enter Master Code + 8 + 8 + [new 4-digit duress code]. To delete the Duress code: Enter your Master Code + 8 + 8, and then stop. When the keypad beeps once it signifies that the code has been deleted. To Change Your Master

Summary of the content on the page No. 12

ENTRY/EXIT DELAYS General Information Your system has preset time delays, known as exit delay and entry delay. When you arm your system, exit delay gives you time to leave through the entry/exit door without setting off an alarm. Entry delay gives you time to disarm the system when you re-enter through the entry/exit door. The system must be disarmed, however, before the entry delay period ends, or an alarm will occur. The keypad will beep slowly during the entry de- lay period, reminding you t

Summary of the content on the page No. 13

CHECKING FOR OPEN ZONES Using the Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING PROTECTION ZONES section), otherwise       READY Key the keypad will display a "Not Ready" message, and if your keypad has a READY indicator light, it will not be lit. The READY key can be used to display all faulted zones, making it easier for you to secure any open zone. To display faulted zones, simply press and release the READY [ ] ke

Summary of the content on the page No. 14

BYPASSING PROTECTION ZONES Using the This key is used when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first.    6   BYPASS Key 1. Enter your security code and press the BYPASS key. LIMITATION 2. Enter the zone number(s) for the zone(s) to be bypassed (e.g., 06, 10, 13, etc.). The system will not Single digit zone numbers must be preceded by a zero (e.g. 05, 06). allow fire zones to 3. When finished, the keypad will momentarily displa

Summary of the content on the page No. 15

BYPASSING PROTECTION ZONES (Continued) Quick Bypass If your system supports "Quick Bypass", it allows you to easily bypass all open (faulted) zones without having to enter zone numbers individually. This feature is useful if, for Ask your installer if example, you routinely leave certain windows open when arming at night. "Quick Bypass" is active for your system, and if To use this feature, enter your security code, press the BYPASS key, then stop. In a few so, check here:     moments, all open

Summary of the content on the page No. 16

ARMING PERIMETER ONLY WITH ENTRY DELAY ON Using the Use this key when staying inside, but expect someone to use an entry/exit door later.    3   STAY Key 1. Enter your security code and press the STAY key. 2. The keypad beeps three times and displays the armed STAY message. The red ARMED indicator lights. Note that there is an exit delay in effect before arming actually BEFORE ARMING, takes place. See the note below. close all doors and windows (see CHECKING FOR OPEN 3. After arming, an alarm s

Summary of the content on the page No. 17

ARMING PERIMETER ONLY WITH ENTRY DELAY OFF Use this key when staying inside and do not expect anyone to use an entry/exit door. Using the  7  INSTANT Key 1. Enter your security code and press the INSTANT key. 2. The keypad beeps three times and displays the armed message. The red ARMED indicator lights. Note that there is an exit delay in effect before arming actually takes BEFORE ARMING, place. See the note below. close all doors and windows (see CHECKING FOR OPEN 3. After arming, an alarm sou

Summary of the content on the page No. 18

ARMING ALL PROTECTION WITH ENTRY DELAY ON Using the Use this key when no one will be staying inside.    2    AWAY Key 1. Enter your security code and press the AWAY key. 2. The keypad beeps twice and displays the armed message. The red ARMED indicator lights. BEFORE ARMING, close all doors and windows 3. You may leave through an entry/exit door during the exit delay period without causing (see CHECKING FOR OPEN an alarm. ZONES on page 13) After the exit delay expires, the system arms and sounds

Summary of the content on the page No. 19

ARMING ALL PROTECTION WITH ENTRY DELAY OFF Using the Use this key when the premises will be vacant for extended periods of time such as vacations, etc., or when retiring for the night and no one will be moving    4    MAXIMUM Key through protected interior areas. 1. Enter your security code and press the MAXIMUM (MAX) key. BEFORE ARMING, close all doors and windows 2. The keypad beeps twice and displays the armed MAXIMUM message. The red (see CHECKING FOR OPEN ARMED indicator lights. ZONES on pa

Summary of the content on the page No. 20

DISARMING THE SYSTEM AND SILENCING ALARMS Using the The OFF key is used to disarm the system and to silence alarm and trouble sounds.    1    OFF Key To Disarm the System Enter your security code and press the OFF key. IMPORTANT: The "Ready" message will be displayed, and the keypad will emit a single tone to confirm If you return and the that the system is disarmed. main burglary sounder is To Silence a Burglary Alarm on, DO NOT ENTER, but CONTACT THE POLICE from a SEE IMPORTANT NOTE AT LEFT! n


Alternative user manuals
# User manual Category Download
1 Honeywell ADEMCO LYNXR Series User manual Home Security System 47
2 Honeywell ADEMCO LYNXR-EN User manual Home Security System 45
3 Honeywell ADEMCO VISTA VISTA-15PSIA User manual Home Security System 22
4 Honeywell ADEMCO VISTA VISTA-20P User manual Home Security System 533
5 Honeywell ADEMCO VISTA VISTA-15P User manual Home Security System 115
6 Honeywell EQUIPMENT MONITORING SYSTEM W8710A User manual Home Security System 3
7 Honeywell ADEMCO VISTA VISTA-20PSIA User manual Home Security System 14
8 Honeywell EKZ008200B User manual Home Security System 16
9 Honeywell GEH User manual Home Security System 1
10 Honeywell Galaxy 16 User manual Home Security System 30
11 Honeywell Galaxy 16 Plus User manual Home Security System 6
12 Honeywell GALAXY 16103 User manual Home Security System 4
13 Honeywell GES User manual Home Security System 1
14 Honeywell GEC User manual Home Security System 0
15 Honeywell HCD544 User manual Home Security System 1
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9