Summary of the content on the page No. 1 
                    
                        Household  
Massage Lounger
Sillón de Masaje Doméstico
Fauteuil vibromasseur
Operating Instructions
Instrucciones de Uso
Mode d’emploi
Model No./Nº de Modelo/Nº de modèle  EP30004
Before operating this unit, please read these instructions completely.
Antes de utilizar esta unidad, lea compleatamente estas instrucciones y guárdelas para referencia futura.
Avant d’utiliser cet appareil, nous vous recommandons de lire l’ensemble de ces instructions et de les ranger dans 
un endroit accessible pour 
                    
                    Summary of the content on the page No. 2 
                    
                        IMPORTANT SAFETY INSTRUCTIONS Basic precautions should always be followed when using an electrical unit, including the following. Please ensure that you read all instructions before using the Household Massage Lounger. DANGER – To reduce the risk of electric shock:  1. Always unplug this unit from the electrical outlet immediately after using and before cleaning. WARNING – To reduce the risk of burns, fire, electric shock, or injury to persons: 1. Always insert the power plug all the way into th
                    
                    Summary of the content on the page No. 3 
                    
                        SAFETY PRECAUTIONS CAUTION: To avoid the risk of injury: 1. Persons with any of the conditions listed below or who are undergoing medical treatment or suffer from medical  conditions should consult with their physicians before using the unit: a) Pregnant women, people who are ill, in poor physical shape. b) People suffering from back, neck, shoulder, or hip pain. c) People who have a pacemaker, defibrillator, or other personal medical devices prone to electronic  interference. d) People sufferin
                    
                    Summary of the content on the page No. 4 
                    
                        OPERATING PRECAUTIONS WARNING: To avoid damaging the chair, follow these precautions: 1. The chair is designed for a maximum user weight of 264 lbs (120 kg). Exceeding the maximum weight may  cause permanent damage to the massage mechanism and/or other components of the unit. Any such damage  is deemed to be user abuse and is not covered under the Limited Warranty. 2. Do not sit on or drop the control panel. Do not pull the control panel cord or the power cord. Be careful not to  catch the cord 
                    
                    Summary of the content on the page No. 5 
                    
                        GROUNDING INSTRUCTIONS This product must be grounded.  If it should malfunction or break down, grounding provides a path of least  resistance for electric current to reduce the risk of electric shock.  This product is equipped with a cord having an  equipment-grounding conductor and a grounding plug.  The plug must be plugged into an appropriate outlet that is  properly installed and grounded in accordance with all local codes and ordinances. DANGER Improper connection of the equipment-grounding
                    
                    Summary of the content on the page No. 6 
                    
                        Part names and functions Main unit Front 3 4 5 6 7 8 2 9 10 11 12  Legrest Legrest Slide Lever Armrest 1 3 10 • Extendable length to approx. 5 in.   Leg/Sole massage section Hand/Arm massage section 2 11 (12 cm) • Includes air massage function • Includes integrated air massage   Control Panel function 4 See page 7 to 8  Control Panel Stand Covers 12  Retracted position of massage • On both the left and right sides 5 heads  Back Cushion 6  Pillow 7 Sole Reflexology Plates  Backrest 8 • Removable 
                    
                    Summary of the content on the page No. 7 
                    
                        Back 13 14 15 16 12 17 18 19 20 21  Back Cover Power Supply Box 13 21  Control Panel Holder 14 Lock Switch Power Switch  Child Safety Decal 15  Control Panel Stand 16  Power Plug 17  Power Cord 18  Safety Precaution Label 19  Wheels 20 Lock Switch Key Lock Switch Key Tag • For preventing children from  swallowing it by accident  6 EP30004.indb   6 2007/07/19   13:07:33                                                                                                                                 
                    
                    Summary of the content on the page No. 8 
                    
                        Control Panel Cover closed 13 Cover open 14 15 17 16  Off/On Voice Guidance Volume Stretch 1 8 14 • See page 36 • See page 33  Quick Stop 2 • Press this button to stop the  Ultra Knead Air Massage Controls 9 15 massage immediately. • “Ultra Knead” is the name of the • Selection of the areas to be air  massage actions. massaged  User Memory 3 • See page 26 to 27 • See page 30 • See page 38 to 40  Repeat Self-Program/Manual Operation  10 16  Program Selection 4 • See page 27 Controls • See page 18
                    
                    Summary of the content on the page No. 9 
                    
                        Display * This illustration simulates when all lights are illuminated.  Voice Guidance Volume Display Pressure Display  Massage Area Display 1 5 11 • See page 36 • Displays the pressure applied by • Flashes to indicate areas  the massage heads currently being massaged Off • In the Massage Area Display,   Massage Style Display 6 positions are estimated.  • Displays the current massage  Soft Therefore, there may be some  style differences between the actual  Medium sensation and the display. Thumb
                    
                    Summary of the content on the page No. 10 
                    
                        Setting up the massage lounger Where to use the unit 1 Keep at least 4" (10 cm) away from the wall. Ensure there is adequate space to recline. Caution Approx. 77" (195 cm) • Do not use the unit in areas with high humidity,  Width approx. 33" (84 cm) such as the bathroom, because this can lead to  Approx. 12" (30 cm) electric shock or other accidents. • Place the unit on a totally flat surface.  Approx. 14"   Failure to do so may result in the unit tipping over. (35 cm) • Do not expose the massag
                    
                    Summary of the content on the page No. 11 
                    
                        Confirm that the main unit and the accessories are in the box. Main unit Width: Approx. 27" (68 cm) Height: Approx. 26" (66 cm) Length: Approx. 63" (160 cm) Accessories • Control Panel Stand • Pillow • Armrests (Right/Left) Control panel  holder Fixing screw Left/Right indication Clip • Control Panel Stand Covers Air plug Small holes on the inside fabric are an intentional  part of the functional design. • Sole Reflexology Plates • Allen Key — 1 (Cross-section) This is installed on the sole  0.2
                    
                    Summary of the content on the page No. 12 
                    
                        Assembly Attaching the  Groove Armrest 1 armrests  (On both the right and left  sides) 1. Insert the armrest into the  unit. • Be careful to avoid pinching  (2)  Fasten the armrest with  your fingers. (1)  Align the the attachment screws. Right/Left  position Main unit indication Pipe 2. Fasten the armrest with the Attachment  Turn screws  attachment screws. Screw clockwise to  tighten. Set the two attachment  screws in place by hand  first and then tighten  firmly with the allen key. Use this S
                    
                    Summary of the content on the page No. 13 
                    
                        Attaching the control panel stand to the right or left side panel of the unit 3 (Diagram shows attachment to right armrest.) 1. Insert the attachment screw into the lower hole first  The position of the control panel when seated can be  and then tighten lightly by hand. selected by choosing the appropriate hole for the screw. 2. Securing the stand with the attachment screws. Near Approx.   Tighten the two screws for the remaining two holes  20˚ lightly by hand and then tighten firmly with the al
                    
                    Summary of the content on the page No. 14 
                    
                        When removing the control panel stand cover 1. Insert the head of a flat-tip screwdriver in the gap  Gap under the mark (O). 2. Push the bottom tab of the cover up to lift the cover. 3. Perform the same procedures as 1 and 2 above for  the other gap. 4. Pull the cover up diagonally. 2 Flat-tip  screwdriver • Performing this procedure with the allen key or a  (Not included in  Phillips screwdriver could damage the unit. the standard  configuration) 1 2 Raising the backrest to the  5 upright posit
                    
                    Summary of the content on the page No. 15 
                    
                        Moving the control panel cord to the left side (when control panel stand is on left  side) Legrest 1. Press the  button on the control panel to turn on the power. 2. Press the  button on the control panel and hold until the legrest  has risen far as it will go. Continue pressing until a “beep-beep-beep” sound is heard. 3. Remove the control panel cord from the cord-holder groove. 4. Move the control panel cord under the legrest to the left side. 5. Fasten the control panel cord at two points in 
                    
                    Summary of the content on the page No. 16 
                    
                        2. Fasten the control panel cord using the clip. Lift the control panel to remove. Clip Fasten the cord so that the  portion under the clip is  Control panel cord not slack. Attaching the pillow 7 1. Attach the pillow to the velcro fasteners. • See page 37 for a guide to the position of the pillow Pillow Velcro  fasteners 15 EP30004.indb   15 2007/07/19   13:07:39                                                                                                                                      
                    
                    Summary of the content on the page No. 17 
                    
                        Before sitting down Check the following before using the unit Check the surrounding area 1 Make sure there are no objects, people, or pets in the vicinity of the unit. Check the power cord and the power plug 2 Warning • Remove dust from the power plug periodically.  Failure to observe this precaution may result in  Check defective insulation of the cord due to moisture.  Clean dust from the cord using a dry cloth. • Do not damage the power cord and the power  plug.  (Do not damage, expose to hea
                    
                    Summary of the content on the page No. 18 
                    
                        2. Make sure there is no foreign objects on  the chair. Caution • Sit on the unit after confirming there is  no foreign matter between the parts of  Hand/Arm  the unit. (Check for foreign objects on  massage section the backrest, leg/sole massage section  or hand/arm massage section.)  Failure to observe this precaution may result  in accident or injury. Leg/Sole massage  section 3. Make sure the massage heads are in the retracted position. Caution • Sit on the unit after confirming the massage 
                    
                    Summary of the content on the page No. 19 
                    
                        Program Massages Pre-Program Quick Massage   Press the  button to turn on the power. 1 • The power will turn off automatically if the massage does not start within 3 minutes after turning on the power. Press one of the flashing buttons ( ) to select the  2 program. Pre-Program and Quick Massage Characteristics (Upper Body) • See page 21 for an overview of the respective programs. SHIATSU: Uses mainly shiatsu massage to loosen STRETCH: Uses mainly compression to slowly  up deep-seated knots of te
                    
                    Summary of the content on the page No. 20 
                    
                        1. Body scanning will commence when the program is selected. The body scanning will properly detect height ranges between approximately 4'7" and 6'8" (140 and 185 cm). Sit as far back in the seat as The unit will automatically  possible with your head on the recline to the correct  Reclined  pillow. measuring position. approx. 12˚ Correct Massage  Position 1 2 Adjust the pillow  3 height so that the  bottom edge of the  4 pillow is at ear level. See page 37. Raised  approx. 55˚ 1 NECK (Neck) 2 S