Anton/Bauer LOGIC Series user manual

User manual for the device Anton/Bauer LOGIC Series

Device: Anton/Bauer LOGIC Series
Category: Battery Charger
Manufacturer: Anton/Bauer
Size: 0.28 MB
Added : 4/30/2013
Number of pages: 23
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Anton/Bauer LOGIC Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Anton/Bauer LOGIC Series.

For your convenience

If looking through the Anton/Bauer LOGIC Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Anton/Bauer LOGIC Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Anton/Bauer LOGIC Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Anton/Bauer LOGIC Series User manual - Online PDF
Advertisement
« Page 1 of 23 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Anton/Bauer LOGIC Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Anton/Bauer LOGIC Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1






DIGITAL BATTERY SYSTEM







Digital ProPac 14
Digital Trimpac 14


OWNER’S MANUAL

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS IMPORTANT..............................................................................1 INTRODUCTION .......................................................................2 FEATURES................................................................................2 HIGH VOLTAGE DESIGN .........................................................4 APPLICATIONS.........................................................................5 DIGITAL PROPAC.............................

Summary of the content on the page No. 4

Summary of the content on the page No. 5

IMPORTANT The Logic Series DIGITAL battery has been specifically designed to be charged with the Anton/Bauer Logic Series InterActive Chargers ONLY (any InterActive 2000 PowerCharger, MP-4D, Quad, Dual, MP-2, Q2, ABC-800H or CPS-2). These Chargers were developed in anticipation of the DIGITAL battery and include the proper DIGITAL interface circuitry. Since all programming is contained on one single EPROM chip, earlier Logic Series Charger models already in the field may not contain t

Summary of the content on the page No. 6

INTRODUCTION The Logic Series Digital Battery System couples the most advanced NiCad battery and charging technology with the first and only capacity measurement system in the industry. The Anton/Bauer DIGITAL battery uses InterActive Logic Series technology which includes sensors, a microprocessor controller and data circuits in the battery to communicate with an Anton/Bauer charger as well as video cameras for precise and dependable performance. The microprocessor actually allows th

Summary of the content on the page No. 7

3. Viewfinder Fuel Gauge Display - The DIGITAL battery was developed in cooperation with all the major equipment manufacturers including Sony, Ikegami, Panasonic, JVC, BTS, and Hitachi. Cameras and camcorders are now available that feature Anton/Bauer compatible InterActive systems that connect with the DIGITAL battery “Fuel Computer” and display an accurate “Fuel Gauge” of remaining battery capacity in the viewfinder. 4. Battery Management Data - The built-in two level LCD in the Lo

Summary of the content on the page No. 8

8. Gold Mount Interface - The solid metal “H” design mounting studs assure a smooth, precise mounting for the life of the battery. The Logic Series connector assembly features multiple gold plated, self aligning contacts and is compatible with all existing Anton/Bauer camera mounts and accessories. 9. Individual Computer Testing - Like all professional Anton/Bauer batteries, the Logic Series DIGITAL battery has been individually computer tested. For assurance of optimum capacity, vol

Summary of the content on the page No. 9

APPLICATIONS Virtually all cameras, camcorders, and other video field equipment specifies a maximum voltage of 18 volts. The 14.4 volt DIGITAL battery will provide superior performance and greater run time on that equipment. CAUTION: Certain older equipment is not designed to accept 14.4 volt NiCad batteries. The 14.4 volt DIGITAL battery could damage such equipment. Check with the equipment manufacturer or the Anton/Bauer Customer Support Group prior to using a 14.4 volt battery.

Summary of the content on the page No. 10

HIGH RATE DISCHARGE For a given size and battery type, higher discharge currents will reduce overall life expectancy while lower discharge currents will enhance overall battery life. The DIGITAL battery incorporates a unique feature that will flash the “LCD” display when a high rate discharge current (equipment load) is applied to the battery. The LCD indicator will resume normal operation when the high rate discharge current is either reduced below the rating or completely removed.

Summary of the content on the page No. 11

CHARGING WITH LOGIC SERIES CHARGERS Charge this battery fully before using. Allow the battery to reach a steady green (Lifesaver) mode before using. Charging is automatic on all Logic Series chargers. The flashing red and green lights indicate the charger and battery are establishing communications. The following are the standard indications on any Logic Series Lifesaver Charger (Please refer to the Charger manual for complete Charger instructions): • Alternating red and green: Eva

Summary of the content on the page No. 12

OVER-DISCHARGED BATTERIES An “over-discharged” voltage state is caused by leaving a battery operated device unattended and allowing the battery to drain beyond the low voltage warning point of the equipment and/or the “Flashing 15 minute segment” indication on the LCD of the DIGITAL battery. Low voltage over-discharged batteries can also be caused by allowing batteries to remain off the charger for extended periods. Returning batteries to the Logic Series Lifesaver Charger as soon as p

Summary of the content on the page No. 13

LIQUID CRYSTAL DISPLAY (LCD) The “RealTime” LCD display provides on-the-fly remaining run time estimates in 15 minute increments as well as simultaneously providing remaining capacity information using the traditional “Fuel Gauge” approach. No special adapters or set up is required. RealTime automatically calculates the load and displays capacity information and battery status at all times. Remaining Runtime Hours Minutes The large numbers 1, 2 or 3 indicate remaining hours un

Summary of the content on the page No. 14

If the INTERACTIVE segment flashes, this indicates the battery has requested to be fully charged and discharged in order to update its “learned capacity”. This “learning” or “calibration” should typically occur during normal equipment operation. However, if the battery has not been fully charged and discharged for some time, this indication will appear. To remove the flashing INTERACTIVE segment, fully charge the battery (STEADY GREEN indication) on the InterActive 2000 charger. Then

Summary of the content on the page No. 15

RealTime Display Indications • When the battery is being charged no remaining runtime is displayed. • Remaining run time is calculated using the present available battery capacity and a constantly updated accurate measurement of the present load on the battery. • If no load is detected, or if the battery is removed from the charger before any discharge load is applied, the default assumed power for remaining run time calculations is 20 Watts. • When the battery determines that a l

Summary of the content on the page No. 16

PREVENTATIVE MAINTENANCE The DIGITAL battery incorporates unique battery management features. Together with Anton/Bauer diagnostic accessories, an effective preventative maintenance program can easily be created to optimize the return on battery investment and greatly simplify battery management operations. The PowerCharger, coupled with a DDM (Diagnostic Discharge Module), will provide a complete battery management system. The PowerCharger will allow you to run diagnostic evaluations

Summary of the content on the page No. 17

GUIDELINES FOR OPTIMUM PERFORMANCE AND MAXIMUM LIFE 1. Keep batteries cool or at room temperatures whenever possible. Sustained elevated temperatures are the primary reason for premature failure of NiCad batteries: a. Charging - Charge batteries at room temperature. In warm climates keep chargers in air conditioned rooms that are maintained between 65°F to 85°F for best performance. b. On assignment - Do not leave batteries in a hot vehicle trunk or out in direct sunlight unnecessar

Summary of the content on the page No. 18

5. Discharging the battery for diagnostic purposes should only be performed on an occasional basis (once every 6-8 weeks at most). Unnecessary discharging only detracts from overall life. 6. Periodic cleaning of both the charger terminals and battery terminals will ensure continued reliable operation. Dirty terminals may cause the battery to indicate a steady red (“Hold”) mode on the charger. Cleaning the terminals with a pencil eraser or lightly scraping the surface with a blunt ins

Summary of the content on the page No. 19

SERVICE In the unlikely event a DIGITAL battery fails to deliver acceptable performance, it must be returned to the Anton/Bauer Service Department, the only facility qualified and equipped to service the Logic Series DIGITAL batteries and calibrate the electronic components and sensors. Any attempt by the user or any other unauthorized persons to service this battery will surely result in improper calibration of the electronic components resulting in severe battery damage and/or safe

Summary of the content on the page No. 20

SPECIFICATIONS DIGITAL DIGITAL PROPAC 14 TRIMPAC OUTPUT 14.4v Nominal 14.4v Nominal 12 ~ 16.8v Operating 12 ~ 16.8v Operating VOLTAGE CAPACITY 65 WH Nominal 45 WH Nominal (CELL CAPACITY) (4 AH Rated) (2.5 AH Rated) @ 15w - 4 Hrs. @ 10w - 4 Hrs. TYPICAL @ 20w - 3 Hrs. @ 13w - 3 Hrs. RUN-TIME @ 30w - 2 Hrs. @ 20w - 2 Hrs. WEIGHT 5.25 lbs. 2.75 lbs. Replacement fuses for the Digital ProPac are valued at 12.5 amps/125 volts. - 16 -


Alternative user manuals
# User manual Category Download
1 Anton/Bauer QUAD 2702 User manual Battery Charger 8
2 Anton/Bauer TITAN T2 User manual Battery Charger 24
3 Anton/Bauer INTERACTIVE 2000 2400 User manual Battery Charger 35
4 Anton/Bauer Twin Two Position Charger User manual Battery Charger 3
5 Anton/Bauer TITAN 70 User manual Battery Charger 0
6 Anton/Bauer Nexus Phantom Battery Package User manual Battery Charger 0
7 Anton/Bauer INTERACTIVE 2000 2700 User manual Battery Charger 26
8 Anton/Bauer ElipZ 10K User manual Battery Charger 16
9 Anton/Bauer DUAL 2702 User manual Battery Charger 5
10 Craftsman 950138 User manual Battery Charger 1
11 Sony AC-L200 User manual Battery Charger 23
12 Sony AC VQ800 User manual Battery Charger 11
13 Sony AC SQ950D User manual Battery Charger 9
14 Sony AC V700A User manual Battery Charger 11
15 Sony AC ADAPTOR AC-V700 User manual Battery Charger 58