Chamberlain LIFTMASTER MUGAPLM user manual

User manual for the device Chamberlain LIFTMASTER MUGAPLM

Device: Chamberlain LIFTMASTER MUGAPLM
Category: Intercom System
Manufacturer: Chamberlain
Size: 0.68 MB
Added : 4/11/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Chamberlain LIFTMASTER MUGAPLM. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Chamberlain LIFTMASTER MUGAPLM.

For your convenience

If looking through the Chamberlain LIFTMASTER MUGAPLM user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Chamberlain LIFTMASTER MUGAPLM on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Chamberlain LIFTMASTER MUGAPLM to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Chamberlain LIFTMASTER MUGAPLM User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Chamberlain LIFTMASTER MUGAPLM but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Chamberlain LIFTMASTER MUGAPLM. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Model MUGAPLM
Multi-Unit Gate Access Panel
®
MUGAPLM Installation &
Assembly
Overview
Step 1
The Multi-Unit Gate Access Panel (MUGAPLM) uses
a digitally secure intercom link that allows it to control
up to four gate operators and other accessories. It
can be used with up to 63 homes and program up to
120 remote control transmitters.
The MUGAPLM is compatible with various LiftMaster
Wireless Products.
Choose mounting location for MUGAPLM. Remove
Carton Inventory
the back panel and attach i

Summary of the content on the page No. 2

NOTE: If there is already an existing receiver proceed to Pre-Installed LiftMaster Receiver Within 20 seconds enter Master PIN Number on (315Mhz Only) section. MUGAPLM: Gate Control Unit (GCU) ? ? ? ? (not provided) Followed by GCU Identity as determined in Step 3: Assemble 3 4 1 OR OR OR 2 Step 1: Remove GCU cover. “BEEP” “BEEP” The GCU LED will blink 3 times indicating programming is successful. NOTE: The relay will engage. If error tone is heard or GCU LED emits 3 double blinks, then p

Summary of the content on the page No. 3

Pre-Installed LiftMaster Programming Accessories Receiver (315Mhz Only) Indoor Multi-Unit Telephone Interface Program (MUOTIU) Indicator Light Step 1: Pry open the front Learn Button panel of the receiver case with a coin or a screwdriver. Step 2: Press and release the Learn button on the receiver. The Indicator Light will light for 30 seconds indicating that receiver is in Learn NOTE: The MUOTIU acts as a wireless remote Mode. autodialer in a dedicated line system. Step 3: Within 30 s

Summary of the content on the page No. 4

Repeater Set Remote Control Transmitter Step 1: On ONE repeater, set Dipswitch #1 to ON. All Each numbered button on a remote control other Dipswitches should remain OFF. transmitter must be programmed separately as each Step 2: Press Learn button on both Repeaters (within button controls one of four GCU’s. 5 seconds of each other). LED will light. Step 1: Enter Master PIN Number on MUGAPLM. Step 3: Within 20 seconds, enter Master PIN Number Step 2: Press “8”. on MUGAPLM. Step 3: Then enter

Summary of the content on the page No. 5

Operation & Features Change Master PIN Number Adding PIN Numbers Enter Master PIN Number on MUGAPLM: The MUGAPLM can support up to 99 PIN Numbers. ? ? ? ? Enter Master PIN Number on MUGAPLM: ? ? 0 9 ? ? “BEEP” 9 # # # “BEEP” Enter new Master PIN Number: Enter new PIN Number: “BEEP” “BEEP” If the new PIN Number applies only to a certain GCU, Speaker Volume enter the PIN Number followed by the GCU Identity Enter Master PIN Number on MUGAPLM: (1-4). The result will be a five digit PIN Number (ex

Summary of the content on the page No. 6

Multi-GAP Mode Alternate Channel Selections The MUGAPLM can be set to Passive Mode to work The MUGAPLM can be set to one of three channels to with multiple MUGAPLM’s. The Passive MUGAPLM will prevent range-reducing interference from conflicting become an accessory to the Active MUGAPLM. Any radio transmitters. Any accessories programmed to the accessories that have been taught to the Passive MUGAPLM will have to have memory cleared and be MUGAPLM will have to have memories cleared and be

Summary of the content on the page No. 7

Multi-GAP Default GCU Setting Battery The Passive MUGAPLM defaults to activating GCU #2 The AA batteries (not provided) in the GCU will last when it is activated by a PIN Number entered on that up to a year and a half depending on use (Lithium keypad, a near-by Remote Control Transmitter, or if the batteries recommended for colder environments.) If Call button is pressed. batteries are low, the intercom will beep three times To have the Passive MUGAPLM activate GCU #3: after it is activat

Summary of the content on the page No. 8

Troubleshooting An error tone is heard when GCU is activated. The MUGAPLM will not program a PIN Number. The MUGAPLM is not communicating with GCU. The The PIN Number is the same number as the factory’s GCU may be out of range or not programmed reset code. Choose another number. correctly. If GCU and MUGAPLM function when close together, the GCU may need to be mounted higher Intercom cannot be programmed. off the ground or on a different surface. Metal, trees, The MUGAPLM has an automatic

Summary of the content on the page No. 9

Modelo MUGAPLM Panel de acceso a la puerta de unidades múltiples ® Instalación y montaje del Descripción general MUGAPLM El Panel de acceso a la puerta de unidades múltiples (MUGAPLM) usa un enlace de intercomunicador que Paso 1 permite controlar hasta cuatro operadores de puerta y otros accesorios. Se puede usar con hasta 63 casas y programarse con hasta 120 transmisores de control remoto. El MUGAPLM es compatible con diversos productos inalámbricos de LiftMaster. Inventario de las cajas

Summary of the content on the page No. 10

NOTA: Si ya hay un receptor existente, pase a la sección Receptor LiftMaster preinstalado (sólo 315 Mhz). En menos de 20 segundos, ingrese el número de PIN principal en el MUGAPLM: Unidad de control de puerta (GCU) ? ? ? ? (no incluidas). Luego ingrese la identificación de la GCU, como se Montaje determina en el Paso 3: Paso 1: Retire la cubierta de O O 3 O 4 1 2 la GCU. “BEEP” “BEEP” El LED de la GCU parpadeará 3 veces, lo que indica que la programación ha sido exitosa. NOTA: El relé come

Summary of the content on the page No. 11

Receptor LiftMaster preinstalado Programación de accesorios (sólo 315 Mhz) Interfaz de teléfono interior con unidades múltiples (MUOTIU) Programación Luz indicadora Botón Paso 1: Abra el panel delantero “Aprendizaje” de la caja del receptor con una moneda o un destornillador. Paso 2: Presione y suelte el botón Aprendizaje del receptor. La luz indicadora se encenderá durante 30 segundos para indicar que el receptor está en el modo NOTA: La MUOTIU actúa como un marcador automático Aprendi

Summary of the content on the page No. 12

Juego de repetidores Transmisor de control remoto Cada botón numerado en un transmisor de control remoto Paso 1: En UN repetidor, configure el conmutador DIP N.º 1 se debe programar en forma separada, ya que cada botón en ENCENDIDO. Todos los demás interruptores DIP deben controla una de las GCU. permanecer APAGADOS. Paso 1: Ingrese el número de PIN principal en el Paso 2: Presione el botón Aprendizaje en ambos MUGAPLM. repetidores (con máximo 5 segundos de diferencia entre sí). Paso 2: P

Summary of the content on the page No. 13

Características y operación Cambie el número de PIN principal Agregar números de PIN Ingrese el número de PIN principal en el MUGAPLM: El MUGAPLM puede tener hasta 99 números de PIN. ? ? ? ? Ingrese el número de PIN Principal en el MUGAPLM: ? ? 0 9 ? ? “BEEP” 9 # # # “BEEP” Ingrese el número de PIN nuevo: Ingrese el número de PIN principal: “BEEP” “BEEP” Si el número de PIN nuevo se aplica sólo a una GCU Volumen del altavoz determinada, ingrese el número de PIN seguido de la identidad de la GC

Summary of the content on the page No. 14

Modo GAP múltiple Alternar selecciones de canales El MUGAPLM se puede configurar en el modo Pasivo para El MUGAPLM se puede configurar en uno de tres canales para trabajar con múltiples MUGAPLM. El MUGAPLM pasivo se evitar que la interferencia que reduce el alcance entre en convertirá en un accesorio para el MUGAPLM activo. Cualquier conflicto con los transmisores de radio. Todo accesorio accesorio que se programó en el MUGAPLM pasivo deberá programado en el MUGAPLM deberá tener la memori

Summary of the content on the page No. 15

Configuración de GCU predeterminada de Batería GAP múltiple Las baterías AA (no incluidas) en la GCU durarán hasta un año y medio dependiendo del uso (se recomiendan las El MUGAPLM pasivo está predeterminado para activar la GCU baterías de litio para ambientes más fríos). Si las baterías N.º 2 cuando sea activado por un número de PIN ingresado en se están agotando, el intercomunicador emitirá una señal ese teclado, un transmisor de control remoto cercano o si se sonora tres veces después

Summary of the content on the page No. 16

Resolución de problemas El MUGAPLM no programará un número de PIN. Se escucha un tono de error cuando se activa la GCU. El número de PIN es el mismo número que el código de El MUGAPLM no se comunica con la GCU. La GCU podrá reinicio de fábrica. Elija otro número. estar fuera de alcance o no estar programada correctamente. Si la función GCU y MUGAPLM estuviesen El intercomunicador no se puede programar. cerca, la GCU deberá montarse a mayor altura del suelo El MUGAPLM tiene una característica


Alternative user manuals
# User manual Category Download
1 Chamberlain CARTON INVENTORY RWIS User manual Intercom System 1
2 Chamberlain LSIS User manual Intercom System 0
3 Chamberlain NTD2 User manual Intercom System 4
4 Chamberlain NLS2 User manual Intercom System 13
5 Chamberlain NDIS User manual Intercom System 1
6 Chamberlain LSIA User manual Intercom System 1
7 Chamberlain NLS1 User manual Intercom System 3
8 Chamberlain NDIS User manual Intercom System 0
9 Chamberlain NDISC User manual Intercom System 0
10 Chamberlain NLS1 User manual Intercom System 48
11 Chamberlain NLS2 User manual Intercom System 5
12 Chamberlain NLS1C User manual Intercom System 0
13 Chamberlain NLS2C User manual Intercom System 0
14 Chamberlain RIFMS2 User manual Intercom System 1
15 Chamberlain RFDI User manual Intercom System 0
16 3M 2475 User manual Intercom System 5
17 3M C5000 User manual Intercom System 1
18 3M 478DA (D-15) User manual Intercom System 4
19 3M D-2400 User manual Intercom System 1
20 3M HEADSET C1060 User manual Intercom System 3