Outback Power Systems Inverter/Charger VFX2612E user manual

User manual for the device Outback Power Systems Inverter/Charger VFX2612E

Device: Outback Power Systems Inverter/Charger VFX2612E
Category: Battery Charger
Manufacturer: Outback Power Systems
Size: 2.26 MB
Added : 10/11/2014
Number of pages: 59
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Outback Power Systems Inverter/Charger VFX2612E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Outback Power Systems Inverter/Charger VFX2612E.

For your convenience

If looking through the Outback Power Systems Inverter/Charger VFX2612E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Outback Power Systems Inverter/Charger VFX2612E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Outback Power Systems Inverter/Charger VFX2612E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Outback Power Systems Inverter/Charger VFX2612E User manual - Online PDF
Advertisement
« Page 1 of 59 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Outback Power Systems Inverter/Charger VFX2612E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Outback Power Systems Inverter/Charger VFX2612E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


OutBack Power Systems
“Export” FX and VFX Inverter/Charger
Installation and Programming Manual
Document Revision 7.1
FX 2012ET - 2.0 kW / 12 VDC / 230 VAC / 50 Hz (Sealed + Turbo / Export)
FX 2024ET - 2.0 kW / 24 VDC / 230 VAC / 50 Hz (Sealed + Turbo / Export)
FX 2348ET - 2.3 kW / 48 VDC / 230 VAC / 50 Hz (Sealed + Turbo / Export)
VFX 2612E - 2.6 kW / 12 VDC / 230 VAC / 50 Hz (Ventilated / Export)
VFX 3024E - 3.0 kW / 24 VDC / 230 VAC / 50 Hz (Ventilated / Export)
VFX 3048E - 3.0 kW

Summary of the content on the page No. 2

Installation & Programming Manual FX & VFX “E” Series Inverter/Charger System Copyright 2003  OutBack Power Systems, Inc. nd 900-0027-2 19009 62 Ave NE, Arlington WA 98223 USA Page 2 Rev 7.1 06/08/06 Tel 360 435 6030 Fax 360 435 6019

Summary of the content on the page No. 3

TABLE OF CONTENTS DECLARATION OF CONFORMITY.................................................................................................. 5 IMPORTANT SAFETY INSTRUCTIONS........................................................................................... 6 Installation Guidelines....................................................................................................................... 6 General Precautions.............................................................

Summary of the content on the page No. 4

STACKING INSTRUCTIONS..............................................................................................................24 OutBack & 3-phase Stacking Methods ...........................................................................................24 Stacking Procedure...........................................................................................................................24 STACK PHASE.............................................................................

Summary of the content on the page No. 5

DECLARATION OF CONFORMITY EU Declaration of Conformity According to ISO / IEC Guide 22 and EN 45014 Product Type: Power Inverter/Charger Product Model Numbers: FX2012E, VFX2612E, FX2024E, VFX3024E, FX2348E, VFX3048E, These products comply with the following EU directives: Electromagnetic Compatibility 89/336/EEC, “Council Directive of 3 May 1989 On the approximation of the laws of member States relating to Electromagnetic compatibility” Low Voltage Directive 73/23

Summary of the content on the page No. 6

IMPORTANT SAFETY INSTRUCTIONS Installation Guidelines This manual contains important instructions for the OutBack FX “Export” (or “E”) series inverter/charger system with the software which allows parallel and 3-phase stacking of multiple units for higher power and/or higher voltage systems. 1 All of the AC field wiring terminals are to be torqued to 30 inch-pounds (equivalent to 2.5 foot-pounds or 3.4 Nm). 2 Wiring to these terminals must meet requirements of the local electric code.

Summary of the content on the page No. 7

IMPORTANT SAFETY INSTRUCTIONS General Precautions 1. Before using the FX, read all instructions and cautionary markings on (1) the FX, (2) the batteries and (3) all appropriate sections of this installation and operation manual. 2. CAUTION - To reduce risk of injury, charge only deep-cycle lead acid, lead antimony, lead calcium, gel cell or absorbed glass mat type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage. 3. The FX is approved for i

Summary of the content on the page No. 8

RATINGS NOMINAL SYSTEM AC VOLTAGE: This is the AC output voltage produced by an FX system. Each FX produces 230 VAC (volts of AC) but multiple FXs can be configured in parallel or 3-phase and these configurations may produce different voltages on the AC output legs. Single Phase 230 VAC at 50 Hz (VAC = volts AC, Hz = Hertz) Parallel Stacked 230 VAC at 50 Hz on one AC output leg Three Phase 230 VAC at 50 Hz per AC output leg (limit three)/400 VAC at 50 Hz between AC output le

Summary of the content on the page No. 9

RATINGS AC INPUT FREQUENCY RANGE: This is the AC input source’s frequency range that the FX will accept and stay connected. If the AC input source is out of this range, the FX will not connect or stay connected. All “Export” FXs 45 - 55 Hz MAXIMUM AC OUTPUT CURRENT: This is the amount of “Surge” current that the FX will supply. This amount of surge can only be supplied for a split second. After this split second the FX lowers this surge limit. Depending on the size of the su

Summary of the content on the page No. 10

MOUNTING All OutBack FX’s can be mounted in any position. Better performance will be achieved if it is mounted in a location which allows for air to circulate around the exterior of the casting. Locating the FX in a cool location will improve the operation and ensure the highest efficiency and power capacity. The following drawing provides the mounting and overall dimensions of the FX with the FXA kit (DCC + ACA + DCA) attached. The first dimension is inches and the second value in

Summary of the content on the page No. 11

COMPLETE OUTBACK INTEGRATED SYSTEMS Shown below are complete systems of OutBack FX’s for indoor installations. The system with four FX’s is shown mounted to the OutBack PSMP (Power System Mounting Plate). The PSMP comes with six 1x20mm thread forming screws for attaching FX’s and breaker boxes. The use of an external toothed star washer (provided) is required on one screw on each piece of equipment in order to bite through the powder coating and ensure grounding of all metal components

Summary of the content on the page No. 12

AC WIRING CONNECTIONS The FX system and the other OutBack balance of system components are designed to make it easy to meet any local and national electrical installation requirements. When used outside of the USA, follow the local installation codes for your country. If you are not familiar with the local installation codes, you should have the equipment installed by a qualified renewable energy equipment dealer or electrician. All wiring methods are to be made in accordance with th

Summary of the content on the page No. 13

INDICATORS / CONTROL WIRING The AC wiring compartment also encloses the green terminal block used for the low voltage control wiring. This six position terminal block can be unplugged to make wiring easier and to simplify the removal and reinstallation of an inverter. Two sets of multi-colored LED indicators are provided to display the operation of the system. One set of three LED’s is provided to indicate the voltage level of the battery connected to the DC terminals of the FX. This

Summary of the content on the page No. 14

BATTERY - FX CABLING DC BATTERY TERMINALS The DC terminals are made from solid brass with a stainless steel threaded stud. The threads are M8 x 1.25”. The black terminal is negative and the red terminal is positive. DO NOT PUT ANY WASHERS BETWEEN THE TERMINAL MOUNTING SURFACE AND THE ACTUAL BATTERY CABLE LUG. Place the flat washer, lock washer and nut on top of the battery terminal lug. TORQUE TO 60 INCH-POUNDS (5 FOOT-POUNDS OR 6.8 NM) MAXIMUM. UL listed DC rated circuit breakers are

Summary of the content on the page No. 15

FX ACCESSORIES FX-ACA (AC CONDUIT ADAPTER) This plastic box slips into grooves on the AC end of the FX. This adapter extends the AC wiring compartment to match the PSAC or PS2AC. It also provides more room for wiring than is available when using the supplied flat knockout plate. There is a 2-inch TSC cut-out on the plastic box to allow it to be used with the PSAC or PS2AC disconnect enclosure. FX-DCA (DC CONDUIT ADAPTER) The FX-DCA allows the connection of

Summary of the content on the page No. 16

HUB COMMUNICATION MANAGER The HUB communication manager allows the MATE to control and monitor a maximum of ten OutBack products. Currently the HUB comes in two types. The HUB-4 can connect up to four Outback FX’s, MX-60 MPPT charge controllers or a combination of the two. The HUB-10 (shown below) can connect up to ten Outback FX’s, MX-60 MPPT charge controllers or a combination of the two. The FX’s can be operated in a stacked or independent configuration. If the FX’s are to be st

Summary of the content on the page No. 17

TURBO KIT INFORMATION The Turbo Kit is an addition that can be added to any sealed FX. It is highly recommended in hot climates or for installations that can use a few hundred watts of extra power. Typically, the Turbo Kit adds 300-500 watts of power to the FX. In hot climates or when the FX is the primary charging device, the chances of the FX overheating are heightened. When the FX gets to its temperature limits, it will back off the charging process to avoid overheating (and a shu

Summary of the content on the page No. 18

FX SYSTEM CONFIGURATION - SINGLE FX SYSTEM The FX System Configuration section shows diagrams of some typical system configurations using the “Export” FX. There are diagrams for a single FX, two FX’s in parallel, four FX’s in parallel, and a 3-phase system. The diagrams show the proper breakers and wiring for the AC side of the installations as well as connections to the HUB or MATE. Also included is information on the maximum continuous power of the systems and proper DC breaker size

Summary of the content on the page No. 19

FX SYSTEM CONFIGURATION - PARALLELED DUAL FX SYSTEM Paralleled Dual FX System The following diagram illustrates a typical paralleled FX installation using two FX’s. For this type of installation, use of OutBack Power Systems PS2 system is recommended. The bypass kit for the PS2 system with two FX’s is an AC-IOB-30D using four CBI breakers with a bypass mechanism. Please specify CBI breakers when ordering this bypass kit. The dual FX system will require two additional CBI 30 amp brea

Summary of the content on the page No. 20

FX SYSTEM CONFIGURATION - PARALLELED QUAD FX SYSTEM Paralleled Quad FX System The following diagram illustrates a typical paralleled FX installation using four FX’s. For this type of installation, use of OutBack Power Systems PS system is recommended. This FX system will require one AC-IOB-60Q bypass kit. The AC-IOB-60Q bypass kit includes two QOU 60 amp breakers for the bypass and four 30 amp CBI breakers for the AC outputs. The quad FX system will require four additional CBI 30 amp


Alternative user manuals
# User manual Category Download
1 Outback Power Systems GRID-INTERACTIVE GVFX User manual Battery Charger 11
2 Outback Power Systems INTERNATIONAL SERIES GFX1312E User manual Battery Charger 5
3 Outback Power Systems GFX1424 User manual Battery Charger 3
4 Outback Power Systems GVFX3524 User manual Battery Charger 9
5 Outback Power Systems GRID-INTERACTIVE GTFX User manual Battery Charger 2
6 Outback Power Systems GFX1548 User manual Battery Charger 9
7 Outback Power Systems GVFX3648 User manual Battery Charger 30
8 Outback Power Systems GTFX3048 User manual Battery Charger 21
9 Outback Power Systems GTFX2524 User manual Battery Charger 6
10 Outback Power Systems Inverter/Charger FX2348ET User manual Battery Charger 15
11 Outback Power Systems Inverter/Charger FX2012ET User manual Battery Charger 3
12 Outback Power Systems INTERNATIONAL SERIES GFX1448E User manual Battery Charger 1
13 Outback Power Systems Inverter/Charger FX2024ET User manual Battery Charger 13
14 Outback Power Systems INTERNATIONAL SERIES GFX1424E User manual Battery Charger 3
15 Outback Power Systems Inverter/Charger VFX3024E User manual Battery Charger 68
16 Craftsman 950138 User manual Battery Charger 1
17 Sony AC-L200 User manual Battery Charger 23
18 Sony AC VQ800 User manual Battery Charger 11
19 Sony AC SQ950D User manual Battery Charger 9
20 Sony AC V700A User manual Battery Charger 11