Bunn DV user manual

User manual for the device Bunn DV

Device: Bunn DV
Category: Beverage Dispenser
Manufacturer: Bunn
Size: 3.2 MB
Added : 4/7/2013
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bunn DV. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bunn DV.

For your convenience

If looking through the Bunn DV user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bunn DV on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bunn DV to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bunn DV User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bunn DV but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bunn DV. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

H10X/H5X
H5E/DV PC
H5 ELEMENT
With Digital Control Board
SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit
the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, and the quickest way to obtain
the latest catalog and manual updates. Contact Bunn-O-Matic Corporation at 1-800-286-6070 to

Summary of the content on the page No. 2

BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor. 2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years. b) C

Summary of the content on the page No. 3

WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. Disconnect the dispenser fromthe power source when servicing, except when electrical tests are required and the test procedure specifically states to connect the dispenser to the power source. CONTENTS TroubleShooting ............................................................................................4 Component Access ..............................................

Summary of the content on the page No. 4

TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by qualified service person- nel. • All electronic components have 120 – 240 volt ac and low voltage dc potential on their terminals. Shorting of terminals or

Summary of the content on the page No. 5

TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Equipment will not operate 2. Safety overflow switch Refer to Service – safety overflow switch (cont.) for testing procedures. Automatic refill will not oper- 1. No water Check plumbing and shut-off valves. ate after drawing hot water. 2. Water strainer/flow control (A) Direction of flow arrow must be point- ing towards dispenser. (B) Remove the strainer/flow control and check for obstructions. Clear or replace. 3. Liquid level system Ref

Summary of the content on the page No. 6

TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Water boils continuously. 1. Temperature control Refer to Service – electronic controls for testing procedures. 2. Lime build-up Inspect the tank assembliy for excess lime deposits. Delime as required. CAUTION – Tanks and tank components should be delimed reglarly depending on local water conditions. Exces- sive mineral build-up on stainless steel surfaces can initiate corrosive reactions resulting in serious leaks. Dispenser is making unu

Summary of the content on the page No. 7

SERVICE WARNING – Disconnect the dispenser from the power source before the removal of any panel or the replacement of any component. WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. Disconnect the dispenser fromthe power source when servicing, except when electrical tests are required and the test procedure specifically states to connect the dispenser to the power source. Component Access - H5E/DV-PC/X Component Acc

Summary of the content on the page No. 8

t t t t This equipmen is o be ins alled o comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE Liquid Level Control Flow Charts Electronic Controls H5E, H5X LIQUID LEVEL CONTROL PROBLEM: Does Not Refill Yes Overflow Cup Full Remove Power ? Drain cup No Retry Disconnect Level Probe Yes Yes Voltage present at Does Water Flow Replace Probe Solenoid

Summary of the content on the page No. 9

SERVICE (cont.) Electronic Controls (cont.) 4. Remove the pink wire from terminal 5 of the elec- tronic control assembly. Liquid Level Control Test Procedure 5. Check the voltage across terminals 1 & 4 of the 1. Disconnect the dispenser from the power source. electronic control board with a voltmeter. Connect 2. Check the voltage across terminals 3 & 4 of the the dispenser to the power source. The indication electronic control board with a voltmeter. Connect must be: the dispenser to the p

Summary of the content on the page No. 10

Electronic Controls (cont.) If voltage was not present as described, check the pink 7. Reconnect the pink wire to terminal 5 of the elec- probe wire and the green ground wire for continuity tronic control assembly. 8. Loosen the compression fitting, remove the probe and/or replace the probe. from the tank lid, and inspect it for mineral depos- Temperature Control Test Procedure its. Replace it if necessary. Keep the exposed ends of the probe away from any metal surface of the 1. Disconnect

Summary of the content on the page No. 11

SERVICE (cont.) Electronic Controls (cont.) If voltage was present as described, the temperature control of the system is operating properly. If voltage was not present as described, contact Bunn-O-Matic to order an electronic control board and temperature sensor for evaluation and proceed to #9. 6. Replace the electronic control board. T5 PNK to Liquid 7. Check the voltage across the tank heater terminals Level Probe with a voltmeter. Connect the dispenser to the T4 WHI or RED to Terminal

Summary of the content on the page No. 12

This equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE (cont.) If voltage was present as described, reconnect the black Limit Thermostat wire and proceed to #5. Location: If voltage was not present as described, refer to the Wir- The limit thermostat is located on the tank lid. ing Diagrams and check the dispense

Summary of the content on the page No. 13

This equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE (cont.) Removal and Replacement: Safety Overflow Switch 1. Disconnect the black wires from the safety overflow switch. 2. Remove the nut beneath the copper overflow cup. 3. Remove the entire switch assembly from the cup. 4. Place the new switch assembly into

Summary of the content on the page No. 14

ill i i li l l i i l l l i ll i ll i l l l l i l i l ! WARNING F water tank before turn ng -on thermostat or connect ng app ance to power source. Use on y on a proper y protected c rcu t capab e of the rated oad. E ectr ca y ground the chass s. Fo ow nat ona / oca e ectr ca codes. Do not use near combust b es. FAILURE TO COMPLY RISKS EQUIPMENT AMAGE, FI E, OR SHO K AZAR D R C H D READ THE ENTIRE OPERATING MANUAL INCLUDING THE LIMIT OF WARRANTY AND LIABILITY BEFORE BUYING OR USING THIS PRODUCT TH

Summary of the content on the page No. 15

SERVICE (cont.) Solenoid Valve (Early Models) If continuity is present as described, reconnect the wires and proceed to #7. Location: If continuity is not present as described, replace the The solenoid valve is located behind the large access solenoid valve coil. panel on the left side of the dispenser. To test the solenoid valve, access will also be needed 7. Check the solenoid valve for coil action. Connect to the electronic control board. the dispenser to the power source. Listen careful

Summary of the content on the page No. 16

This equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE (cont.) Tank Heater 4. Remove the tank heater from the tank lid and in- Location: spect it for cracks in the sheath. The tank heater is located in the tank lid. If the sheath shows no sign of damage, proceed to #5. If the sheath is damaged, replace the tank he

Summary of the content on the page No. 17

SERVICE (cont.) Removal and Replacement: Steam Sensor (Thermistor) 1. Disconnect the dispenser from the power source. 2. Disconnect the thermistor from J5 on control Location: board. The thermistor is located on the end of the overflow 3. Loosen the set screw and the two screws securing tube above the overflow cup. the two half blocks together. Remove thermistor To test the thermistor, access will also be needed to assembly from overflow tube. the electronic control board. 4. Install new th

Summary of the content on the page No. 18

SERVICE (cont.) Dispense Valve (PC Only) If voltage is not present as described, refer to Wir- Location: ing Diagrams and check the dispenser wiring harness. The Dispense Valve is located behind control panel. Also check the control board for proper operation. Removal and Replacement: 1. Disconnect the dispenser from the power source and allow to cool. 2. Drain enough water from the tank so the water level is below the outlet. Bracket 3. Remove the nut and flare nut from the valve. Shroud 4.

Summary of the content on the page No. 19

MEMBRANE SWITCH ASSY Ready Power Heater Manual Dispense/Stop Left Dispense Middle Dispense Right Dispense “Hidden” Switch J2 6 10 1 5 N L2 L1 SCHEMATIC WIRING DIAGRAM H5E-DV PC GRN BLK-14 RED-14 Earth Ground MASTER ON/OFF SWITCH Chassis Ground RED-14 BLK-18 SELECTOR LIMIT SWITCH TANK HEATER THERMOSTAT BRN-14 BLK-14 BLK-14 4000 W TANK HEATER WHI/VIO-14 WHT-14 1800 W N.C. REFILL WHT-18 WHI/BLU-18 120VAC SOL OVERFLOW PROTECTION SWITCH 4 3 WHI-18 J7 2 1 WHT-18 VI

Summary of the content on the page No. 20

MEMBRANE SWITCH ASSY Ready Power Heater Manual Dispense/Stop Left Dispense Middle Dispense Right Dispense “Hidden” Switch J2 6 10 1 5 L1 L2 SCHEMATIC WIRING DIAGRAM H5E-PC GRN RED-14 BLK-14 Earth Ground EMI FILTER Chassis Ground BLK-18 RED-14 LIMIT LIMIT THERMOSTAT THERMOSTAT TANK HEATER BLK-14 BLK-14 BLU-14 BLU-14 4000 W N.C. REFILL WHI/BLU-18 230VAC RED-18 OVERFLOW SOL PROTECTION SWITCH 4 3 RED-18 DISPENSE J7 2 1 RED-18 VIO-18 230VAC SOL 5 4 N.O. 3 COM 2 1


Alternative user manuals
# User manual Category Download
1 Bunn CDS-3 User manual Beverage Dispenser 6
2 Bunn IC3B User manual Beverage Dispenser 3
3 Bunn AF PR-3 User manual Beverage Dispenser 1
4 Bunn FMD-2 User manual Beverage Dispenser 2
5 Bunn FMD-5 User manual Beverage Dispenser 1
6 Bunn TDS5 User manual Beverage Dispenser 0
7 Bunn Chilled LCC-2 User manual Beverage Dispenser 1
8 Bunn FMD-2 User manual Beverage Dispenser 1
9 Bunn JDF-4S User manual Beverage Dispenser 0
10 Bunn ULTRA-2 User manual Beverage Dispenser 4
11 Bunn FMD DBC-3 4-CUP User manual Beverage Dispenser 1
12 Bunn TDS3.5 User manual Beverage Dispenser 0
13 Bunn ITCB-DV User manual Beverage Dispenser 0
14 Bunn FMD-5 User manual Beverage Dispenser 3
15 Bunn ICD3 User manual Beverage Dispenser 0
16 Sony KDL-40V4100 User manual Beverage Dispenser 4
17 Sony KDL-46V4100 User manual Beverage Dispenser 2
18 Sony KDL-40W4100 User manual Beverage Dispenser 3
19 Sony KDL-40V4150 User manual Beverage Dispenser 2
20 Sony KDL-46W4150 User manual Beverage Dispenser 1