Icom 201 user manual

User manual for the device Icom 201

Device: Icom 201
Category: Marine Radio
Manufacturer: Icom
Size: 1.2 MB
Added : 7/6/2014
Number of pages: 55
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Icom 201. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Icom 201.

For your convenience

If looking through the Icom 201 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Icom 201 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Icom 201 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Icom 201 User manual - Online PDF
Advertisement
« Page 1 of 55 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Icom 201 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Icom 201. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


®
ICOM 200/201/241

Summary of the content on the page No. 2

Summary of the content on the page No. 3

About this manual 1 ICOM-200 / 201 2 ICOM-241 3 Advice and support 4 Register 5

Summary of the content on the page No. 4

Copyright © by Wilke Technology GmbH Krefelder Str. 147 52070 Aachen / Germany manual version 1.4 This manual, together with the hardware and software which it describes, is copyrighted and may not be in any way copied, translated or redered in any other form without the express written consent of Wilke Technology GmbH. Note The editors, translators and authors of this publication have taken great care with the texts, illustrations and programs. Nevertheless, errors cannot be complet

Summary of the content on the page No. 5

Contents Contents 1 About this manual 1-1 Typographic conventions and symbols 1-2 2 ICOM-200 / 201 2-1 Versions 2-1 Differences between ICOM-200 and ICOM-201 2-1 First steps 2-2 Power supply 2-2 PC mode 2-2 RUN mode 2-3 Program download 2-3 SLEEP mode 2-4 Keyboard 2-6 LC display 2-8 Serial Interface 2-9 RS232 2-9 RS485 2-10 Opto inputs 2-11 Power outputs 2-13 Analog inputs 2-15 Analog inputs 2-15 Configuration 0...5V 2-16 Configuration 0…10V 2-17 Configuration 0...20mA 2

Summary of the content on the page No. 6

Contents Opto inputs 3-4 Power outputs 3-6 Serial interface 3-7 RS232 3-7 RS 485 3-8 Analog inputs 3-11 Pin layout 25-pin D-Sub connector 3-14 Technical data 3-15 ICOM 241 – 24V 3-16 Connection to PC 3-17 Technical data 3-17 4 Hints and help 4-1 ® BASIC-Tiger Service Hotline: 4-1 5 Register 5-1 . ii Wilke Technology GmbH • 0241 / 918 900 • http://www.wilke.de/ • support@wilke.de

Summary of the content on the page No. 7

General 1 About this manual 1 This manual does introduce you into the control of the ICOM industry computer family for a fast and easy use. The ICOM industry computer family combines the performance of ® BASIC/TINY-Tiger Computers with steadily needed I/O peripherals in an elegant aluminum chassis. For programming the ICOM industry ® computers a BASIC-Tiger development system is needed. This manual only describes the usage of the ICOM industry computers. ® You can read about the pr

Summary of the content on the page No. 8

ICOM-manual 1 Typographic conventions and symbols Following fonts and symbols are used for fast identification of important informations: Element Meaning KEY Key description, e.g. RETURN ® Program listing Tiger-BASIC program listing ® Instruction Tiger-BASIC instruction Variable Variables or constants you have to enter according to your application. [ ] Elements which can be entered optional. Important remark: Please note! ! Tipps and hints simplifying your work. Tip 1-2

Summary of the content on the page No. 9

ICOM-200 / 201 2 ICOM-200 / 201 Versions This manual describes the ICOM200 and ICOM201 til version V1.3. Newer 2 versions are described in separate data sheets. At ICOM versions V1.4 or newer, the version number is printed on the right hand side of the device. Differences between ICOM-200 and ICOM-201 The ICOM-201 is a special version of the ICOM-200. The following decription shows where the differences between the ICOM-200 and ICOM-201 are. Feature ICOM-200 ICOM 201 Graphic LCD •

Summary of the content on the page No. 10

ICOM-manual First steps Power supply The ICOM-200/201 uses a power supply with 8-12 VDC, 1A. Minus is placed on the pin of the power supply connector. The current consumption is, depending on the application, up to 400mA. 2 PC mode ® After a reset or power-down the Tiny-Tiger inside the ICOM-200/201 is testing if the PC mode pin is „low“. In this case, the ICOM switches to PC mode/Debug mode. Is the pin „high“, the ICOM starts in run mode. The time between power-on and first activit

Summary of the content on the page No. 11

ICOM-200 / 201 RUN mode If the DIP-switch “PC/Run” is in position “Run”, the program in the ICOM- 200/201 is executed immediately after a reset. Debugging is not possible in this mode. Program download 2 A program created with the Tiger software is downloaded into ICOM-200/201 through the 9-pin Sub-D connector. To download the following has to be done: Connect a power supply 8-12 V DC (Polarity: Inner contact = minus, outer contact = plus) Connect ICOM-200/201 and PC with 9-pin D

Summary of the content on the page No. 12

ICOM-manual SLEEP mode ® The ICOM-200/201 can be put into sleep mode if the Tiny-Tiger inside has a real time clock. In sleep mode the power consumption of the ICOM-200/201 is descreased significantly to just approx. 25mA. While in sleep mode, no BASIC program is executed by the ICOM-200/201. 2 Sleep circuit ® The internal clock and SRAM of the Tiny-Tiger are buffered through a Goldcap. The power consumption of clock and SRAM is approx. 70µA, with a fully loaded Goldcap this is enough

Summary of the content on the page No. 13

ICOM-200 / 201 2 ® To put the ICOM-200/201 into sleep mode, the alarm time for the Tiny-Tiger clock has to be set. Following that the ICOM-200/201 falls into sleep mode and wakes up again at alarm time. More detailled information on how to set ® the alarm time can be found in the BASIC-Tiger „Device driver“ manual. If jumper J9 has been drawn and the Goldcap is unloaded, it takes about 30 seconds from connecting the power supply before the ICOM-200/201 switches on. Wilke Technolo

Summary of the content on the page No. 14

ICOM-manual Keyboard The ICOM-200 has a 20 key matrix keyboard. The keyboard is devided into two blocks. The first block has four vertically arranged keys placed directly on the right side of the LC display. Those keys can e.g. be assigned to a menu on the LC display. The second block consists of 16 labeled keys. 2 Reading the keyboard is done with the device driver „LCD1.TDD“. The following example scans the keyboard and gives back a numeric code for the pressed key. Additionally a cha

Summary of the content on the page No. 15

ICOM-200 / 201 '-------------------------------------------------------------------- '----- ICOM_KEYB.TIG '-------------------------------------------------------------------- #define keyb 20 ' keyboard device nummer #include define_a.inc user_var_strict TASK Main 2 word x,n,i string a$ user_eport lastladr,10h user_eport physoffs, 0f0h Dir_port 8,0 INSTALL DEVICE #lcd,"LCD2.TDD",0,0,0EEH,1,150,11H' LCD-1=128x64, 150 KB/s Install device #keyb, "LCD1.tdd", 0, 0,

Summary of the content on the page No. 16

ICOM-manual LC display The ICOM-200 has a graphic LC display with a resolution of 128 x 64 pixel. There’s a special device driver to control this display. By using this device driver it is possible to control the LC display with simple BASIC commands. Detailled information about usage of this device driver „LCD-6963.TDD“ is part ® 2 of the „Device driver“ manual of the BASIC-Tiger . The LC display has LED backlight. The backlight’s power consumption is approx. 250mA. Power supply is 5V

Summary of the content on the page No. 17

ICOM-200 / 201 Serial Interface As a standard the ICOM-200 and ICOM-201 have two serial interfaces. From these the port Ser0 can by choice be configured as RS232 or RS485 interface. The port Ser1 always is a RS232 interface. In PC mode this port is used for downloading the program into the ICOM 200/201. In Run mode it can be used as a usual RS232 interface. 2 Detailled information about the serial interfaces can be read after in the ® BASIC-Tiger „Device driver“ manual. RS232 Seria

Summary of the content on the page No. 18

ICOM-manual The pins of serial port 0 are located on the DB-37 connector: RS232 DB-37 TXD0 (Output) 16 RXD0 (Input) 17 RTS0 36 2 CTS0 35 RS485 The configuration of port 0 as RS485 interface is done by removing the IC3 (MAX232) and placing the IC12 (SN75176) into the 8-channel DIL socket. The DIP switch on the left side plate of the ICOM-200/201 has to be set to RS485. Removing or placing the ICs is only allowed without power supply. Never place both ICs at the same time, this could

Summary of the content on the page No. 19

ICOM-200 / 201 Opto inputs The ICOM-200/201 has eight optocoupler inputs suited for an input voltage range of 5...12 VDC. To use higher input voltages, as 24V for example, an additional serial resistor in the input line is used. The resistor value is selected in accordance to 4...50mA input current needed for the logical “1” level. 2 The internal resistance is 680 Ohm / 0,25 W. If now another input voltage is needed, the totally required resistance can be calculated with the following

Summary of the content on the page No. 20

ICOM-manual '-------------------------------------------------------------------- '----- ICOM200_OPTOIN.TIG '-------------------------------------------------------------------- #include define_a.inc user_var_strict TASK Main BYTE wert 2 USER_EPORT lastladr,10h USER_EPORT physoffs, 0f0h DIR_PORT 8,0 DIR_PORT 7,0 INSTALL_DEVICE #lcd,"LCD2.TDD",0,0,0EEH,1,150,11H' LCD-1=128x64,150 KB/s OUT 8,11111111b,11011111b ' set CTRL-Pins of T6963C OUT 8,10000000b,255


Alternative user manuals
# User manual Category Download
1 Icom IC-2800H User manual Marine Radio 128
2 Icom 241 User manual Marine Radio 14
3 Icom IC-460 User manual Marine Radio 12
4 Icom IC-7000 User manual Marine Radio 193
5 Icom IC-2200H User manual Marine Radio 634
6 Icom IC-F14/S User manual Marine Radio 34
7 Icom IC-756 User manual Marine Radio 224
8 Icom IC-F1810 User manual Marine Radio 8
9 Icom IC-F1710 User manual Marine Radio 6
10 Icom IC-F110 User manual Marine Radio 118
11 Icom IC-F210 User manual Marine Radio 57
12 Icom IC-208H User manual Marine Radio 201
13 Icom IC-450 User manual Marine Radio 6
14 Icom IC-F24/S User manual Marine Radio 24
15 Icom IC-F2810 User manual Marine Radio 3
16 Acu-Rite #01088 User manual Marine Radio 0
17 Acu-Rite 02010CDI User manual Marine Radio 2
18 Acu-Rite 972 User manual Marine Radio 0
19 Acu-Rite #02036WB User manual Marine Radio 6
20 Acu-Rite 01502BPDI User manual Marine Radio 0