Sennheiser SK 50_250 user manual

User manual for the device Sennheiser SK 50_250

Device: Sennheiser SK 50_250
Category: Microphone
Manufacturer: Sennheiser
Size: 1.57 MB
Added : 11/5/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sennheiser SK 50_250. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sennheiser SK 50_250.

For your convenience

If looking through the Sennheiser SK 50_250 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sennheiser SK 50_250 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sennheiser SK 50_250 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sennheiser SK 50_250 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sennheiser SK 50_250 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sennheiser SK 50_250. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SK 50_250 Titel.fm Seite 1 Montag, 4. April 2005 11:09 11

SK 50
SK 250
Bedienungsanleitung
Instructions for use
Notice d‘emploi
Istruzioni per l‘uso
Instrucciones para el uso
Gebruiksaanwijzing
Bruksanvisning

Summary of the content on the page No. 2

SK 50_250 Titel.fm Seite 3 Montag, 4. April 2005 11:09 11 Gebrauchsanleitung .................................. 3 Instructions for use.................................. 17 Instructions pour l’usage ........................ 31 Istruzioni per l’uso ................................... 45 Mode de empleo ....................................... 59 Gebruiksaanwijzing ................................. 73 Bruksanvisning......................................... 87

Summary of the content on the page No. 3

SK 50 INSTRUCTIONS FOR USE MIKROPORT BODY-PACK TRANSMITTER SK 250 17

Summary of the content on the page No. 4

CONTENTS 1. BRIEF DESCRIPTION 19 2. CONTROLS AND CONNECTIONS 20 3. MICROPHONE SELECTION 21 4. USING FOR THE FIRST TIME 21 4.1. B 50 / B 250 QUICK-CHANGE ENERGY PACK 21 4.2. BA 50 / BA 250 QUICK-CHANGE ENERGY PACK 23 4.3. POSSIBLE COMBINATIONS OF TRANSMITTERS WITH THE QUICK-CHANGE ENERGY PACK 24 5. CHANNEL SELECTION 24 6. SWITCHING ON 24 7. SENSITIVITY SETTING 25 8. ATTACHMENT OF THE BODY-PACK TRANSMITTER 25 9. LICENSING REGULATIONS 26 10. TECHNICAL DATA SK 50 UHF / SK 250 UHF 27 11. TECHNICAL DA

Summary of the content on the page No. 5

1. BRIEF DESCRIPTION MODELS FREQUENCY RANGE SWITCHING BAND WIDTH CHANNELS SK 50 UHF 450 bis 960 MHz 24 MHz 16 SK 250 UHF 450 bis 960 MHz 24 MHz 16 SK 50 VHF (1) 138 bis 160 MHz 22 MHz 16 SK 50 VHF (2) 153 bis 181 MHz 28 MHz 16 SK 50 VHF (3) 174 bis 202 MHz 28 MHz 16 SK 50 VHF (4) 195 bis 223 MHz 28 MHz 16 SK 50 VHF (5) 223 bis 260 MHz 37 MHz 16 SK 250 VHF (1) 138 bis 170 MHz 38 MHz 16 SK 250 VHF (2) 170 bis 225 MHz 55 MHz 16 SK 250 VHF (3) 210 bis 260 MHz 50 MHz 16 In combination with a connecte

Summary of the content on the page No. 6

2. CONTROLS AND CONNECTIONS 7 1 6 2 5 4 3 1 ANTENNA SOCKET 2 CHANNEL SELECTION SWITCH 3 OPERATING TIME DISPLAY 4 ON / OFF SWITCH 5 OPERATING / PEAK DEVIATION INDICATOR 6 SENSITIVITY SELECTOR SWITCH FOR MICROPHONE INPUT 7 MICROPHONE INPUT 20

Summary of the content on the page No. 7

3. MICROPHONE SELECTON The MKE 2-4, MKE 102-4 (omnidirectional polar pattern) and MKE 40-4 (cardioid polar pattern) Lavalier chlip-on microphones are available. They are equipped with a special Lemo plug. The plug is disconnected by unscrewing the threaded collar. The voltage necessary to operate these microphones is available at the microphone input of the transmitter. Dynamic microphones and other low-impedance sources can be connected through an external coupling condenser of approx. 10 µ F (

Summary of the content on the page No. 8

FIG. 2 FIG. 3 QUICK-CHANGE ENERGY PACK QUICK-CHANGE ENERGY PACK B 50 B 250 CLOSE COVER NOTE: ALKALINE-MANGANESE BATTERIES OF THE "MIGNON" LRC AA TYPE ARE TO BE USED EXCLUSIVELY. PERFECT FUNCTIONING OFTHE TRANSMITTER IS GUARANTEED ONLY WITH THIS TYPE OFBATTERY. 22 + + + + +

Summary of the content on the page No. 9

4.2. BA 50 / BA 250 QUICK-CHANGE ENERGY PACK The LCD display on the front side of the energy pack (Fig. 4) servers as a battery control display. FIG. 4 RECHARGEABLE BATTERY DISPLAY 100 % 80 % 60 % 40 % 20 % STARTS TO BLINK IF THE REMAINING OPERATING TIME FALLS BELOW 30 MIN. In addition to the visual display on the quick-change energy pack, the transmitter communicates the status of the batteries or the rechargeable batteries to the EM 1046 for presentation on the receiver display. FIG. 5 RELEASI

Summary of the content on the page No. 10

4.3. POSSIBLE COMBINATIONS OF TRANSMITTERS WITH THE QUICK-CHANGE ENERGY PACK FIG. 6 SK 50-UHF SK 50-UHF SK 50-UHF SK 50-UHF SK 50 B 50 B BA 50 BA 250 250 SK 250-UHF SK 250-UHF SK 250-UHF SK 250-UHF SK 250 B 50 B BA 50 BA 250 250 The SK 250 / B 50 and SK 250 / BA 50 combinations are not possible because the power of the battery / rechargeable battery pack is not adequate for this transmitter. 5. CHANNEL SELECTION To select the appropriate channel or the appropriate frequency in accordance with th

Summary of the content on the page No. 11

7. SENSITIVITY SELECTOR SWITCH The sensitivity selector switch 6 can be used to adapt the gain of the microphone input in 8 steps to the level of the sound expected. This setting is to be made in combination with a receiver which has a peak indicator available, such as the EM 1046. The sensitivity is set correctly when the "peak" indicator 5 lights up brightly during level peaks. The microphone is to be held or mounted in its position for later use when setting. The corresponding display on the

Summary of the content on the page No. 12

FIG, 7 Note: The transmitter can also be attached so that the cable and antenna point downwards. 9. LICENSING REGULATIONS The type plate contains the channel data and the transmit frequency data as well as the BZT approval, which you require for your application for the licence from the Post Office. It is located on the underside of the device. 26

Summary of the content on the page No. 13

10. TECHNICAL DATA SK 50 UHF / SK 250 UHF Transmit frequencies 16 Frequency range 450 - 960 MHz Switching band width 24 MHz Frequency stability ± 5 ppm Spurious and emmissions < 4 nW Modulation FM Nominal / peak deviation ± 40 kHz / ± 56 kHz Compander Sennheiser HiDyn plus Input sensitivity for peak deviation 13.2 mV - 1.55 V 8-position switch Audio frequency range 70 Hz - 20 kHz Dynamics 110 dB(A) eff. THD < 0.3 % (nominal peak / 1 kHz) Connections AF: Lemo special (3-pin) RF: Lemo special Koa

Summary of the content on the page No. 14

11. TECHNICAL DATA SK 50 VHF Transmit frequencies 16 Frequency range SK 50 VHF (1) 138 ... 160 MHz SK 50 VHF (2) 153 ... 181 MHz SK 50 VHF (3) 174 ... 202 MHz SK 50 VHF (4) 195 ... 223 MHz SK 50 VHF (5) 223 ... 260 MHz Switching band width SK 50 VHF (1) 22 MHz SK 50 VHF (2) 28 MHz SK 50 VHF (3) 28 MHz SK 50 VHF (4) 28 MHz SK 50 VHF (5) 37 MHz Frequency stability ± 10 ppm Spurious and emmissions < 4 nW Modulation FM Nominal / peak deviation ± 40 kHz / ± 56 kHz Compander Sennheiser HiDyn plus Inpu

Summary of the content on the page No. 15

11. TECHNICAL DATA SK 250 VHF Transmit frequencies 16 Frequency range SK 250 VHF (1) 138 ... 170 MHz SK 250 VHF (2) 170 ... 225 MHz SK 250 VHF (3) 210 ... 260 MHz Switching band width SK 250 VHF (1) 38 MHz SK 250 VHF (2) 55 MHz SK 250 VHF (3) 50 MHz Frequency stability ± 10 ppm Spurious and emmissions < 4 nW Modulation FM Nominal / peak deviation ± 40 kHz / ± 56 kHz Compander Sennheiser HiDyn plus Input sensitivity for peak deviation 13 mV - 1.55 V 8-position switch Audio frequency range 70 Hz -

Summary of the content on the page No. 16

KONFORMITÄTSERKLÄRUNG Sennheiser electronic GmbH & Co. KG, Am Labor 1, D-30900 Wedemark erklären, daß dieses Gerät den einschlägigen Anforderungen der EG-Richt- linie 89/336/EWG entspricht. Zur sachgemäßen Umsetzung der in den EG-Richtlinien genannten Anforde- rungen wurden folgende Normen herangezogen: ETS 300 445 ETS 300 422 Bemerkung: Vor Inbetriebnahme sind die jeweiligen länderspezifischen Vorschriften zu beachten! CERTIFICATE OF CONFORMITY Sennheiser electronic GmbH & Co. KG, Am Labor 1, D

Summary of the content on the page No. 17

CERTIFICATO DI CONFORMITÁ Sennheiser electronic GmbH & Co. KG, Am Labor 1, D-30900 Wedemark dichiariamo che questo apparecchio risponde alla normativa 89/336/EWG. Per un’appropriato risconto nell’ambito della normativa CEE sono state consultate le seguenti normative: ETS 300 445 ETS 300 422 Nota: Prima della messa in funzione seguite le prescrizioni vigenti nel paese nel quale viene utilizzato! DECLARACIÓN DE CONFORMIDAD Sennheiser electronic GmbH & Co. KG, Am Labor 1, D-30900 Wedemark declaramo

Summary of the content on the page No. 18

106 Sk 50 letzte Seiten 106 04.02.2002, 11:10 Uhr

Summary of the content on the page No. 19

107 Sk 50 letzte Seiten 107 04.02.2002, 11:10 Uhr

Summary of the content on the page No. 20

SK 50_250 Titel.fm Seite 2 Montag, 4. April 2005 11:09 11 Sennheiser electronic GmbH & Co. KG 30900 Wedemark, Germany Phone +49 (5130) 600 0 Fax +49 (5130) 600 300 www.sennheiser.com Printed in Germany Publ. 04/05 48208/A07


Alternative user manuals
# User manual Category Download
1 Sennheiser 005069 User manual Microphone 3
2 Sennheiser 05067 MZW 34 B User manual Microphone 1
3 Sennheiser 05063 ME 35 User manual Microphone 3
4 Sennheiser 05069 MZW 36 B User manual Microphone 2
5 Sennheiser 05060 ME 34 User manual Microphone 1
6 Sennheiser 05065 ME 36 User manual Microphone 0
7 Sennheiser 086740 User manual Microphone 0
8 Sennheiser 03736 User manual Microphone 1
9 Sennheiser 083297 User manual Microphone 1
10 Sennheiser 100 Series User manual Microphone 25
11 Sennheiser 375ZB2050CE (5900735) User manual Microphone 0
12 Sennheiser 09421 User manual Microphone 0
13 Sennheiser 2690443 User manual Microphone 0
14 Sennheiser 16948991 User manual Microphone 0
15 Sennheiser 418S User manual Microphone 12
16 Edelbrock 15541 User manual Microphone 0
17 Sony DWA-01D User manual Microphone 0
18 Sony ECM DM5P User manual Microphone 6
19 Sony ECM Z37C User manual Microphone 29
20 Sony DWT-B01 User manual Microphone 27