Helio PM5500 user manual

User manual for the device Helio PM5500

Device: Helio PM5500
Category: Blender
Manufacturer: Helio
Size: 0.85 MB
Added : 5/25/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Helio PM5500. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Helio PM5500.

For your convenience

If looking through the Helio PM5500 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Helio PM5500 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Helio PM5500 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Helio PM5500 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Helio PM5500 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Helio PM5500. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

U S E R M A N U A L
HELIO2
HELIUM-Oxyg En B LEnd Er
(DISS and NIST Connections)
Model No. PM5400 Series (shown)
PM5500 Series
SAVE THESE INSTRUCTIONS
Federal (USA) law restricts this device to sale
CAUTION
by or on the order of a physician.
300 Held Drive Tel: (+001) 610-262-6090
Northampton, PA 18067 USA Fax: (+001) 610-262-6080
www.precisionmedical.com

Summary of the content on the page No. 2

CONTENTS RECEIVING / INSPECTION ................................................................1 INTENDED USE ..................................................................................1 READ ALL INSTRUCTIONS BEFORE USING ...................................1 Ex PLANATION OF ABBREVIATIONS ................................................2 SAFETY INFORMATION - WARNINGS AND CAUTIONS ..................2 SPECIFICATIONS .........................................................................

Summary of the content on the page No. 3

REAd ALL INSTRUCTIONS BEFORE USING This manual instructs a Professional to install and operate the HELIO2 Blender. This is provided for your safety and to prevent damage to the HELIO2 Blender. If you do not understand this manual, DO NOT USE the HELIO2 Blender and contact your Provider. dANGER This product is not intended as a life-sustaining or life-supporting device. ExPLANATION OF ABBREVIATIONS FIHe-O2 Fractional Concentration of Inspired Helium-Oxygen FIO2 Fractional Concentration of Ins

Summary of the content on the page No. 4

WARNING • Only trained, qualified medical personnel under the direct supervision of a licensed physician should operate the HELIO2 Blender. • Use this HELIO2 Blender only for its Intended Use as described in this manual. • Confirm prescribed dose before administering to patient. Monitor on a frequent basis. Continuous Monitoring with an alarmed Oxygen Monitor / Analyzer is recommended. • The HELIO2 Blender shall be serviced by a qualified service technician. • Always follow ANSI and CGA stan

Summary of the content on the page No. 5

SPECIFICATIONS High Flow Low Flow Model PM5580: 80/20 heliox PM5480: 80/20 heliox PM5570: 70/30 heliox PM5470: 70/30 heliox 15 - 120 lpm 3 - 30 lpm Primary Outlet Flow Range With both supply pressures at 50 psi (3.4 bar) with BLEED Closed 2 - 100 lpm 0 - 30 lpm Auxiliary Outlet Flow Range With both supply pressures at 50 psi (3.4 bar) with BLEED Open 13 lpm or less 3 lpm or less Bleed Flow @ at 50 psi (3.4 bar) at 50 psi (3.4 bar) 100% FIO2 Maximum Combined ≥ 120 lpm ≥ 30 lpm Flow (All Outl

Summary of the content on the page No. 6

SPECIFICATIONS continued dimensions: (without fittings) (12.5 cm) Depth: 4.9 in (5.7 cm) Width: 2.3 in Height: 4.1 in (10.4 cm) (1.3 kg) Weight: 2.9 lbs (1.6 kg) Shipping Weight: 3.5 lbs Operating Temperature Range: 59°F to 104°F (15°C to 40°C) Transport / Storage Requirements -10°F to 140°F (-23°C to 60°C) Temperature Range: Max 95% Noncondensing Humidity: ± 3% of full scale @ 50 psi (3.4 bar) FIO2 Accuracy:* Pressure drop: Low Flow: ≤ 2 psi (0.14 bar) at inlet pressures from 30-90 psi

Summary of the content on the page No. 7

dIAGRAMS CAUTION Missing or illegible labels must be replaced, contact Precision Medical, Inc. PM5400 and PM5500 Models B A E F H G D C HELIO2 BLENDEr HELIUM-Oxyg En 6

Summary of the content on the page No. 8

COMPONENT dESCRIPTION ITEM DESCRIPTION Oxygen Concentration dial A A dial used for selecting oxygen concentrations between 20% -100% or 30% -100%. The FIO2 scale is used for reference only. The actual FIO2 must be verified with an Alarmed Oxygen Monitor / Analyzer. This dial does not rotate 360°. The dial starts at 20% or 30% and ends at 100%. Primary Outlet Port B A male DISS oxygen fitting with check valve that delivers flow when engaged to any controlling device, such as a flo

Summary of the content on the page No. 9

PRE-USE TESTING WARNING • Read this User Manual before installing or operating the HELIO2 Blender. • Confirm the concentration of heliox with an alarmed Oxygen Monitor / Analyzer. • Confirm contents of heliox cylinder prior to use. CAUTION Inspect the HELIO2 Blender for visual damage before use, DO NOT USE if damaged. NOTE: The tests listed below should be performed prior to placing the HELIO2 Blender in service. Pre-Use Testing consists of: • Alarm Test • Reverse Gas Flow Procedure 1. Secure

Summary of the content on the page No. 10

REVERSE GAS FLOW PROCEdURE (CE Requirements ONLY) 1. Assure bleed flow valve is not engaged. Disconnect the oxygen hose from the gas source. Remove all outlet connections from the HELIO2 Blender to ensure that there is no outlet flow. 2. Place the free end of the oxygen supply hose under water. While gradually increasing the heliox supply pressure from 30-75 psi (2.07-5.17 bar) check for leakage past the oxygen inlet check valve. 3. Replace the Duckbill Check Valve in the oxygen inlet, if le

Summary of the content on the page No. 11

7. Confirm the concentration of heliox with an Oxygen Monitor / Analyzer. If necessary activate the bleed flow valve to maintain FIO2 accuracy. 8. To activate the bleed, turn and rotate the knurled collar back until it contacts the cover. 9. To deactivate the bleed, pull and rotate the collar away from the cover until bleed flow valve is closed. 10. Turn “OFF” the heliox and oxygen supply or disconnect when the HELIO2 Blender is not in use. CLEANING CAUTION • dO NOT steam autoclave. • dO

Summary of the content on the page No. 12

OxYGEN FLOWMETER CONVERSIONS Oxygen Corrected Heliox Flow (LPM) at Various FIO2 Settings Flowmeter Setting 20% 30% 40% 50% 60% 70% 80% 90% 100% 1 1.8 1.6 1.4 1.3 1.2 1.18 1.15 1.02 1.0 2 3.6 3.2 2.8 2.6 2.4 2.4 2.3 2.0 2.0 3 5.4 4.8 4.2 3.9 3.6 3.5 3.5 3.1 3.0 4 7.2 6.4 5.6 5.2 4.8 4.7 4.6 4.1 4.0 5 9.0 8.0 7.0 6.5 6.0 5.9 5.8 5.1 5.0 6 10.8 9.6 8.4 7.8 7.2 7.1 6.9 6.1 6.0 7 12.6 11.2 9.8 9.1 8.4 8.3 8.1 7.1 7.0 8 14.4 12.8 11.2 10.4 9.6 9.4 9.2 8.2 8.0 9 16.2 14.4 12.6 11.7 10.8 10.6 10.4 9.2

Summary of the content on the page No. 13

TECHNICAL dESCRIPTION For a complete Technical Description of the HELIO2 Blender and list of Replacement Parts, reference the HELIO2 Blender Service Manual (P/N 506124) available on the Internet; www.precisionmedical.com. RETURNS Returned products require a Returned Goods Authorization (RGA) number, contact Precision Medical, Inc. All returns must be packaged in sealed containers to prevent damage. Precision Medical, Inc. will not be responsible for goods damaged in transit. Refer to Pre

Summary of the content on the page No. 14

TROUBLESHOOTING If the HELIO2 Blender fails to function, consult the Troubleshooting Guide below. If problem cannot be solved by using Troubleshooting Guide, refer to the HELIO2 Blender Service Manual (P/N 506124) available on the Internet; www.precisionmedical.com or consult your Provider. Problem Probable Cause Remedy 1. •HIg H flow model, 1. Use auxiliary outlet & Oxygen concentration flow requirement engage bleed discrepancy below 15 lpm. between Blender •LOW flow model, setting and fl

Summary of the content on the page No. 15

LIMITEd WARRANTY ANd LIMITATION OF LIABILITY Precision Medical, Inc. warrants that the HeliO2 Blender, (the Product), will be free of defects in workmanship and/or material for the following period: Two (2) years from shipment Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Med

Summary of the content on the page No. 16

dECLARATION OF CONFORMITY Manufacturer: Precision Medical, Inc. 300 Held Drive, Northampton, PA 18067, USA CONTACT: Quality Manager Phone: 610-262-6090 Authorized European Representative: Emergo Europe (European Office) Molenstraat 15 2513 BH, The Hague The Netherlands Phone: +31 (0) 70.345.8570 Fax: +31 (0) 70.346.7299 Product: Gas Mixers for Medical Use (Blender) Model(s): PM5470EN, PM5480EN, PM5570EN, PM5580EN MDD Class: IIb Classification criteria: Clause 3.2 Rule 11 of Annex IX of MD


Alternative user manuals
# User manual Category Download
1 Helio PM5400 User manual Blender 0
2 Craftsman 875.50242 User manual Blender 0
3 Sony DHG-HDD500 User manual Blender 3
4 Sony DHG-HDD250 User manual Blender 1
5 Philips Food Processor HR7740 User manual Blender 43
6 Philips hr 7745 User manual Blender 43
7 Philips HR1370 User manual Blender 9
8 Philips AVENT SCF860/20 User manual Blender 12
9 Philips HR1721 User manual Blender 3
10 Philips HR1724 User manual Blender 0
11 Philips HR1372 User manual Blender 39
12 Philips HR1720 User manual Blender 2
13 Philips HR1727 User manual Blender 1
14 Philips HR1371 User manual Blender 13
15 Philips AVENT SCF860 User manual Blender 3