METRObility Optical Systems 2152-AJ-01 user manual

User manual for the device METRObility Optical Systems 2152-AJ-01

Device: METRObility Optical Systems 2152-AJ-01
Category: Network Cables
Manufacturer: METRObility Optical Systems
Size: 0.19 MB
Added : 8/17/2013
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for METRObility Optical Systems 2152-AJ-01. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with METRObility Optical Systems 2152-AJ-01.

For your convenience

If looking through the METRObility Optical Systems 2152-AJ-01 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual METRObility Optical Systems 2152-AJ-01 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual METRObility Optical Systems 2152-AJ-01 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
METRObility Optical Systems 2152-AJ-01 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual METRObility Optical Systems 2152-AJ-01 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to METRObility Optical Systems 2152-AJ-01. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
Gigabit “twister” and
®
SONET “twister”
™ ™
“twister” 2152 “twister” 2152
1000BASE-LX 1000BASE-SX 1000BASE-LX 1000BASE-TX
PWR
PWR
BWDM
TX MM RX BWDM
LINK LINK LINK LINK
™ ™
“twister” 2152 “twister” 2152
1000BASE-LX 1000BASE-TX 1000BASE-LX 1000BASE-SX
PWR
PWR
TX SM RX TX MM RX
TX SM RX
LINK LINK LINK LINK
™ ™
“twister” 2152
“twister” 2151
1000BASE-LX 1000BASE-TX 1000BASE-LX 1000BASE-SX
PWR
PWR
SM TX SM RX TX MM RX
LINK LINK LINK LINK


“twister” 2135 “twister” 2125
OC-12 OC-12 OC-3 OC

Summary of the content on the page No. 2

® Metrobility Gigabit “twister” and SONET “twister” Multimode-to-Singlemode Converter: 2125-34-01 ____ OC-3/STM-1 multimode SC to singlemode SC 2125-37-01 ____ OC-3/STM-1 multimode SC to singlemode SC (40km) 2135-34-01 ____ OC-12/STM-4 multimode SC to singlemode SC 2151-AD-01 ____ 1000Base-SX multimode SC to 1000Base-LX singlemode SC Fiber-to-Fiber Repeater: 2152-AA-01 ____ 1000Base-SX multimode SC to 1000Base-SX multimode SC 2152-AD-01 ____ 1000Base-SX multimode SC to 1000Base-LX singlemode SC

Summary of the content on the page No. 3

Metrobility Gigabit Table of Contents “twister” and SONET “twister” Installation & User Guide Introduction ................................................................................................................ 4 Overview ..................................................................................................................... 5 Installation Guide ....................................................................................................... 6 STEP 1: Unpack the “twis

Summary of the content on the page No. 4

Introduction The Metrobility Gigabit “twister” and SONET “twister” represent the latest technology available for extending Gigabit Ethernet, OC-3/STM-1 and OC-12/STM- 4 networks. Since Metrobility first developed “twister” media conversion, it has set the standard for providing affordable means of integrating mixed media networks. As LANs/WANs grow and evolve, this technology provides an ideal solution for building effective migration strategies. In addition to the standalone unit, the “twister”

Summary of the content on the page No. 5

Overview The Metrobility “twister” provides seamless integration between fiber optic multimode and singlemode segments in Gigabit Ethernet, OC-3/STM-1 or OC-12/ STM-4 environments. It supports copper to fiber translation as well as wavelength conversion from 850nm to 1310 or 1550nm, and from 1310nm to 1550nm. With the “twister”, you can increase your network reach up to 70km on a single segment. For networks that require extended distance support, use the 2152-series repeaters. The repeaters rec

Summary of the content on the page No. 6

Follow the simple steps outlined in this section of the guide to install and start Installation Guide using your Metrobility “twister”. Unpack the “twister” and Accessories Check that the following components have been included: • Metrobility “twister” • Power supply • Power cord • Four (4) rubber feet Your order has been provided with the safest possible packaging, but shipping damage does occasionally occur. Inspect your order carefully. If you discover any shipping damage, notify your carrier

Summary of the content on the page No. 7

™ “twister” 2152 1000BASE-LX 1000BASE-SX PWR TX SM RX TX MM RX OFF PWR LINK LINK ON DC INPUT/5VDC Port 2 Port 1 OFF OFF ON or or ON ON OFF DIP switches (2152 TX-FX) DIP switches (2152 FX-FX) DIP switches (all others) NOTE: The ON/OFF positions are not the same on all units. By default, all DIP switches are disabled. Link Loss Return (LLR) Switch The Metrobility “twister” incorporates Link Loss Return functionality as an aid in troubleshooting remote fiber connections. When LLR is enabled on a

Summary of the content on the page No. 8

LLCF is enabled when the LLCF switch is in the ON position. The fiber-to- fiber repeater is shipped with LLCF disabled. On the fiber-to-fiber convert- ers (2151-AD-, 2125-xx- and 2135-34-01), LLCF is always enabled and cannot be disabled. Sliding the LLCF switch up and down on these models has no effect. LLCF is not applicable to the copper-to-fiber repeaters. For more information, refer to Link Loss Carry Forward in the User Guide section of this manual. Copper Loss Carry Forward (CLCF) Switch

Summary of the content on the page No. 9

Fiber Optic Interface Multimode ports are labeled MM. Singlemode ports are labeled SM. Extended distance ports are labeled LH (Long Haul) or ELH (Extended Long Haul). Each fiber port provides an SC or LC connector. For informa- tion about the cable lengths supported by each model, refer to the table in the Technical Specifications section. When making connections, be sure that the transmit (TX) optical conductor of the “twister” connects to the receive (RX) optical conductor of the connected dev

Summary of the content on the page No. 10

OFF PWR ON DC INPUT/5VDC Upon receiving power, the “twister” goes into normal operation mode. Verify valid connections via the PWR LED on the front panel. If an additional extension cord is used to connect the power supply to the outlet, follow the guidelines below. While one end of the AC power cord can be fitted with whatever plug is standard for the country of operation, the end that connects to the “twister” unit’s power supply must have a female plug that fits this type of AC receptacle. •

Summary of the content on the page No. 11

User Guide This section contains more detailed information regarding the operating features of the Metrobility “twister”. LED Indicators The Metrobility “twister” provides three LEDs on the front panel for the visible verification of unit status and proper functionality. The LEDs also aid in trouble- shooting and overall network diagnosis and management. When lit, the LEDs indicate the following status: • PWR (power): The unit is powered ON. • LINK (Port 1): Port 1 is receiving idle link signals

Summary of the content on the page No. 12

Link Loss Return (LLR) The fiber ports on the “twister” have been designed with Link Loss Return function- * ality for troubleshooting remote connections. When LLR is enabled , the port’s transmitter (TX) shuts down if its receiver (RX) fails to detect a valid receive link. LLR should only be enabled on one end of a cable and is typically enabled on either the unmanaged or remote device. LLR works in conjunction with LLCF and CLCF. The diagram below shows a typical network configuration with goo

Summary of the content on the page No. 13

Link Loss Carry Forward (LLCF) The fiber-to-fiber “twister” units incorporate LLCF functionality to assist in trouble- * shooting a remote connection. When LLCF is enabled , the ports do not transmit link signals until they receive link signals from the opposite port. When a lost link signal is returned to an unmanaged “twister” unit, that lost link must then be carried forward to a managed device (switch/hub) for trap generation. LLCF works in conjunction with LLR. The diagram below shows a typ

Summary of the content on the page No. 14

Copper Loss Carry Forward (CLCF) The copper-to-fiber “twister” incorporates CLCF for identifying a lost copper * connection. When CLCF is enabled , the fiber port’s transmitter shuts down if the copper port stops receiving link pulses. However, the copper port continually transmits link signals regardless of whether or not the fiber port detects link. The diagram below shows a typical network configuration with good link status using two copper-to-fiber “twister” units for remote connectivity. N

Summary of the content on the page No. 15

Topology Solutions Enterprise Switch Servers Enterprise “twister” Switch “twister” singlemode F/O “twister” singlemode F/O Switch “twister” singlemode F/O Multimode F/O Links Singlemode F/O Links Technical Specifications Twisted-Pair Interface Connector _____________________________________________________ RJ-45 Impedance_________________________________________________ 50Ω typical Signal Level Output (differential) ____________________________ 0.95 to 1.05V Supported Link Length _______________

Summary of the content on the page No. 16

Fiber Optic Interface Cable RX RX TX TX Fiber Wave Cable Size Input Input Output Output Power Model Type Length Length Core/ Power Power Power Power Budget* Clad (min) (sat) (min) (max) 2km 50/ -m 30dBm-m 14dB-m 23.5dB-m 14dB 6.5dB (rated) 125µm 2125-34 Mm M 1310n 2125-37 2km 62.5/ -m 30dBm-m 14dB-m 20dB-m 14dB 10dB (rated) 125µm 15km (rated, 2M 125-34Sm 1310n based on9m /125µm-m 35dB-m 8dB-m 15dB-m 8dB 20dB power budget) SM 40km 2125-37 1310nm 9m /125µm-m 35dB0m dB-m 5dB0m dB 30dB (LH) (rated)

Summary of the content on the page No. 17

BWDM Interface Connector ________________________________________________________ SC Supported Link Length ________________________________________ up to 20km Cable Type _______________________________________________ 9/125µ m F/O Output Power _________________________________________ -9 dBm to -3 dBm RX Input Sensitivity ___________________________________ -20 dBm minimum Wavelength (2152-1X-01, 2152-AX-01) Transmitter _______________________________________________ 1550 nm Receiver ___________

Summary of the content on the page No. 18

Product Safety, EMC and Compliance Statements This equipment complies with the following requirements: •UL • CSA • EN60950 (safety) • FCC Part 15, Class A • EN55022 Class A (emissions) • DOC Class A (emissions) • EN55024: 1998 (immunity) • IEC 825-1 Classification • Class 1 Laser Product This product shall be handled, stored and disposed of in accordance with all govern- ing and applicable safety and environmental regulatory agency requirements. The following FCC and Industry Canada compliance i

Summary of the content on the page No. 19

Warranty and Servicing Three-Year Warranty for the Metrobility “twister” Metrobility Optical Systems, Inc. warrants that every “twister” product will be free from defects in material and workmanship for a period of THREE YEARS. This warranty covers the original user only and is not transferable. Should the unit fail at any time during this warranty period, Metrobility will, at its sole discretion, replace, repair, or refund the purchase price of the product. This warranty is limited to defects i

Summary of the content on the page No. 20

Product Manuals The most recent version of this manual is available online at http://www.metrobility.com/support/manuals.htm Product Registration To register your product, go to http://www.metrobility.com/support/registration.asp 25 Manchester Street, Merrimack, NH 03087 tel: 1.603.880.1833 • fax: 1.603.594.2887 www.metrobility.com 5660-2151AD-01 J 2/04


Alternative user manuals
# User manual Category Download
1 METRObility Optical Systems 2125-37-01 User manual Network Cables 0
2 METRObility Optical Systems 2152-1D-01 User manual Network Cables 1
3 METRObility Optical Systems 2152-17-01 User manual Network Cables 0
4 METRObility Optical Systems 2152-1A-01 User manual Network Cables 0
5 METRObility Optical Systems 2151-AD-01 User manual Network Cables 0
6 METRObility Optical Systems 2152-1F-01 User manual Network Cables 0
7 METRObility Optical Systems 2135-34-01 User manual Network Cables 0
8 METRObility Optical Systems 2152-1K-01 User manual Network Cables 0
9 METRObility Optical Systems 2152-1J-01 User manual Network Cables 0
10 METRObility Optical Systems 2152-1M-01 User manual Network Cables 0
11 METRObility Optical Systems 2152-1X-01 User manual Network Cables 0
12 METRObility Optical Systems 2152-1Y-01 User manual Network Cables 0
13 METRObility Optical Systems 2152-77-01 User manual Network Cables 0
14 METRObility Optical Systems 2152-A7-01 User manual Network Cables 0
15 METRObility Optical Systems 2152-AD-01 User manual Network Cables 0
16 Sony 273 User manual Network Cables 1
17 Sony User manual Network Cables 1
18 Sony BKM-FW32 User manual Network Cables 2
19 Sony PEGA-HS10 User manual Network Cables 2
20 3Com Nokia 6100 User manual Network Cables 0