Summary of the content on the page No. 1 
                    
                        AdderView CATx
User Guide
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Summary of the content on the page No. 2 
                    
                        Contents Introduction Configuration AdderView CATx features - front and rear ................................5 Overall initial configuration  ....................................................23 What’s in the box.........................................................................6 Configuration menus ................................................................24 What you may additionally need ...............................................6 Configuration menus layout .................
                    
                    Summary of the content on the page No. 3 
                    
                        HT Operation Further information The front panel controls ...........................................................50 Getting assistance ......................................................................68 AdderView CATx models ..................................................50 Troubleshooting ........................................................................68 AdderView CATx IP models ..............................................50 Appendix 1 – Configuration menus ...............
                    
                    Summary of the content on the page No. 4 
                    
                        HT Appendix 3 - VNC viewer connection options .........................94 Appendix 7 – Cable and connector specifications .................104 Colour/Encoding ...................................................................94 RS232 serial mouse to PS/2 converter cable  .....................104 Inputs .....................................................................................95 AdderView CATx to power switch cable  ..........................104 Scaling ...............................
                    
                    Summary of the content on the page No. 5 
                    
                        Introduction Thank.you.for.choosing.the.AdderView.CATx.series. This.description,.however,.is.far.from.sufficient.to.tell. The.AdderView.CATx.IP.variants.introduce.true.global. from.Adder.Technology..Each.of.the.four.models. you.that.those.four.users.can.easily.be.situated.up.to. control.for.the.multiple.host.systems..Up.to.four.global. have.been.designed.to.take.full.advantage.of.CATx. 300m.(980.feet).from.the.unit,.using.Adder.X100.or. users.can.share.access.to.a.computer.from.anywhere. structu
                    
                    Summary of the content on the page No. 6 
                    
                        Front panel buttons IP network port (CATx IP only) AdderView CATx features - front and rear The.COMPUTER.and.USER.buttons.allow. The.port.by.which.global.users. the.local.user.to.select.the.required. are.linked.to.the.AdderView.CATx. The.AdderView.CATx.units.pack.a.great.deal.of.functionality.into.a.compact. combination..Adjacent.numeric.displays. unit..This.intelligent.Ethernet.port. space..All.models.occupy.a.single.1U.rack.space.and.provide.most.of.their. show.the.current.selection..Keyboard,
                    
                    Summary of the content on the page No. 7 
                    
                        What’s in the box What you may additionally need Computer Access Modules  One.required.per.connected.computer..There.are.five. different.formats,.depending.on.the.required.computer. connections: PS/-style  Connectors:Analog video, PS/2-style keyboard and  PS/2-style mouse. Part.number:.CATX-PS2 PS/-style with audio  Connectors:Analog video, PS/2-style keyboard, PS/2- style mouse and 3.5mm audio jack. Part.number:.CATX-PS2A USB  Connectors:Analog video and USB keyboard/mouse.  Part.number:.CATX
                    
                    Summary of the content on the page No. 8 
                    
                        HT Installation Mounting The.AdderView.CATx.units.offer.two.main.mounting.methods: •. Supplied.four.self-adhesive.rubber.feet •. Supplied.rack.brackets Rack brackets The.two.supplied.brackets.(plus.four.screws),.allow. Connections the.AdderView.CATx.unit.to.be.secured.within.a. standard.1U.rack.slot.. Note: Both the AdderView CATx and its  power supply generate heat when in  operation and will become warm to the  touch. Do not enclose them or place them  in locations where air cannot circulate  
                    
                    Summary of the content on the page No. 9 
                    
                        Connections The.AdderView.CATx.and.CATx.IP.units.provide.a.great.deal.of.flexibility.in.their.configurations.. This.chapter.details.the.various.connections.that.can.be.made.to.achieve.the.required.installation. Local Remote user  Global user  REMOTEREMOTE user (via X100 extender) (IP network port) USER USER page 9 page 10 page 11 X100 X100 CAM CAM Power Modem/ Multiple video  HOST in ISDN port head connections COMPUTER page 21 page 14 page 13 Cascading  multiple units X100 IP page 16 MODEM /ISDN
                    
                    Summary of the content on the page No. 10 
                    
                        Local user A.locally.connected.video.monitor,. To connect the local user port keyboard.(and.mouse).are.required. 1. Position.a.suitable.video.monitor,.keyboard,.mouse.(and.speakers,.if. during.the.initial.configuration.. required).in.the.vicinity.of.the.AdderView.CATx.unit.such.that.their.cables. These.are.also.useful.during.normal. will.easily.reach. use.to.allow.quick.local.control.of. 2. Attach.the.video.monitor,.keyboard,.mouse.(and.speaker).connectors.to. any.connected.computer.systems.. th
                    
                    Summary of the content on the page No. 11 
                    
                        Remote user (via X100/X200 extender) Up.to.four.users.can.be.placed.a. 3. Lay.a.suitable.length.of.category.5,.5e.or.6.cabling.between.the.Adder. maximum.of.300.metres.(980.feet). X100/X200.module.and.the.AdderView.CATx.unit..Please.refer.to.the. from.the.AdderView.CATx.unit.. section.Cable lengths for remote user locations.opposite. Remote.users.are.connected.via. 4. Attach.the.connector.of.the.cable.run.to.the.socket.of.the.Adder.X100/X200. an.Adder.X100.or.X200.extender. module.and.suitable.c
                    
                    Summary of the content on the page No. 12 
                    
                        Global user (IP network port) The.AdderView.CATx.IP.models. To connect the Global user (IP network) port provide.an.autosensing.Ethernet. 1. Depending.upon.where.in.the.network.the.AdderView.CATx.IP.is.being. IP.port.that.can.operate.at.10.or. connected,.run.a.category.5,.5e.or.6.link.cable.from.the.appropriate.hub.or. 100Mbps,.according.to.the.network. router.to.the.AdderView.CATx.IP.unit. speed..The.AdderView.CATx.IP. 2. Connect.the.plug.of.the.link.cable.into.the.IP.port.on.the.front.panel.of
                    
                    Summary of the content on the page No. 13 
                    
                        Computer system (via CAM) Each.computer.system.is.connected. 4. Attach.the.connector.of.the.cable. to.the.AdderView.CATx.unit.via.a. run.to.the.socket.of.the.CAM. Computer.Access.Module.(CAM). and.standard.category.5,.5e.or. Green indicator - power present 6.cabling..CAMs.are.available.in. Yellow indicator - signal activity  various.formats.to.suit.differing. computer.system.types.and.their. particular.connector.styles. Computer  Access  To connect a computer system Module 1. Ensure.that.power.i
                    
                    Summary of the content on the page No. 14 
                    
                        Modem/ISDN port The.AdderView.CATx.IP.models. To connect a modem or ISDN adapter provide.a.serial.port.to.allow.you. 1. If.possible,.disconnect.power.from.the.AdderView.CATx.IP.and.the.modem. to.connect.either.a.modem.or.ISDN. or.ISDN.adapter. terminal.adapter..This.can.be.used. 2. Connect.a.suitable.serial.modem.(non-crossover).cable.to.the.serial.port.on. as.a.primary,.secondary.or.backup. the.modem/ISDN.adapter. access.port.for.global.users,.as.best. 3. Connect.the.other.end.of.the.serial.cab
                    
                    Summary of the content on the page No. 15 
                    
                        Power in connection The.AdderView.CATx.unit.is. 2. Connect.the.IEC.connector.of.the.supplied.country-specific.power.lead.to. supplied.with.a.single.30W.power. the.socket.of.the.power.adapter. adapter.which.is.sufficient.to.supply. any.configuration.of.the.unit..The. AdderView.CATx.IP.unit.has.two. power.input.sockets.to.allow.an. auxiliary.(redundant).power.adapter. to.be.connected..There.is.no.on/off. switch.on.the.unit,.so.operation. begins.as.soon.as.a.power.adapter. is.connected. Note: Adder
                    
                    Summary of the content on the page No. 16 
                    
                        To connect and address the switch boxes Power control port Note: The AdderView CATx IP unit can be powered on during this procedure,  The.AdderView.CATx.IP.models.provide. however, the switch boxes should be switched off. a.serial.port.for.connection.to.one.or. 1. Mount.up.to.four.switch.boxes.in.positions.where.they.are.close.to.the. more.optional.power.control.units.. computer.systems.that.they.will.control.and.not.too.distant.from.the. This.allows.you.to.control.the.mains. AdderView.CATx.IP.u
                    
                    Summary of the content on the page No. 17 
                    
                        Cascading multiple units X100 IP The.AdderView.CATx.(IP).units. MODEM The cascade tree support.up.to.sixteen.or.twenty. /ISDN The.diagram.shows.how.multiple.AdderView.CATx.units.can.be. four.directly.connected.computer. cascaded.up.to.three.levels..Computer.systems.can.be.connected.at. any.level..Up.to.four.users.(local,.remote.or.global).can.simultaneously. systems,.however,.this.is.by. POWER access.computer.systems.situated.around.the.cascade.tree... IN no.means.the.limit..Thanks.to. CAM an.in
                    
                    Summary of the content on the page No. 18 
                    
                        How cascade connections operate The.method.for.cascading.AdderView.CATx.units.is.straightforward. and.requires.no.hardware.settings.or.lengthy.configuration.process.. This.is.due.to.the.Adder Port Direct.communication.system.that. allows.them.to.locate.each.other.and.share.information. The.method.of.linking.AdderView.CATx.units.is.the.same. regardless.of.the.cascade.level,.or.number.of.devices.attached..Put. simply:. •	 A single cascade link is made by connecting a computer  connections socket o
                    
                    Summary of the content on the page No. 19 
                    
                        CA02 B01 Addressing computers in a cascade The.addressing.format.used.by.the.AdderView.CATx.units. incorporates.the.various.group letters.along.with.a.final.specific. port.number.to.which.a.required.computer.is.attached..In.the. diagram.given.here,.a.portion.of.the.previous.cascade.diagram. indicates.how.the.routes.to.particular.computers.are.formed.and. addressed.... Each.cascade.level.requires.a.group.letter.followed.by.a.two. AdderView CATx or AdderView CATx IP Group C figure.final.port.numbe
                    
                    Summary of the content on the page No. 20 
                    
                        Connecting AdderView CATx units in cascade To connect units in cascade Please.consider.the.following.when.making.cascade.connections.between. 1. Ensure.that.power.is.disconnected.from.the.AdderView.CATx.and.all.other. AdderView.CATx.units. units.to.be.connected.... Tips for successful cascading 2. Connect.one.end.of.each. •. The.maximum.number.of.levels.for.a.cascade.is.three. cascade.link.cable.to.an. •. The.maximum.number.of.computer.systems.that.can.be.controlled.within. appropriate.COMPUTER