National Instruments PXI PXITM -1000 user manual

User manual for the device National Instruments PXI PXITM -1000

Device: National Instruments PXI PXITM -1000
Category: Network Card
Manufacturer: National Instruments
Size: 0.44 MB
Added : 6/19/2014
Number of pages: 55
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments PXI PXITM -1000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments PXI PXITM -1000.

For your convenience

If looking through the National Instruments PXI PXITM -1000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments PXI PXITM -1000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments PXI PXITM -1000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments PXI PXITM -1000 User manual - Online PDF
Advertisement
« Page 1 of 55 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments PXI PXITM -1000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments PXI PXITM -1000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

PXI

PXI -1000 User Manual
PXI-1000 User Manual
January 1998 Edition
Part Number 321710B-01

Summary of the content on the page No. 2

Internet Support E-mail: support@natinst.com FTP Site: ftp.natinst.com Web Address: http://www.natinst.com Bulletin Board Support BBS United States: 512 794 5422 BBS United Kingdom: 01635 551422 BBS France: 01 48 65 15 59 Fax-on-Demand Support 512 418 1111 Telephone Support (USA) Tel: 512 795 8248 Fax: 512 794 5678 International Offices Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 288 3336, Canada (Ontario) 905 785 0085, Canada (Québec) 514 694 8521, Denmark

Summary of the content on the page No. 3

Important Information Warranty The PXI-1000 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor. The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, d

Summary of the content on the page No. 4

Compliance FCC/DOC Radio Frequency Interference Class A Compliance This equipment generates and uses radio frequency energy and, if not installed and used in strict accordance with the instructions in this manual, may cause interference to radio and television reception. Classification requirements are the same for the Federal Communications Commission (FCC) and the Canadian Department of Communications (DOC). This equipment has been tested and found to comply with the following two regul

Summary of the content on the page No. 5

For Your Safety Caution Before undertaking any troubleshooting, maintenance, or exploratory procedure, ! read carefully the WARNING and CAUTION notices. This equipment contains voltage hazardous to human life and safety, and is capable of inflicting personal injury. • Mainframe Grounding—The PXI-1000 mainframe requires a connection from the premise wire safety ground to the PXI-1000 chassis ground. The earth safety ground must be connected during use of this equipment to minimize shock haza

Summary of the content on the page No. 6

Contents About This Manual Organization of This Manual.........................................................................................xi Conventions Used in This Manual.................................................................................xi Related Documentation..................................................................................................xii Customer Communication .............................................................................................

Summary of the content on the page No. 7

Contents Cleaning......................................................................................................................... 3-1 Interior Cleaning ............................................................................................. 3-2 Exterior Cleaning ............................................................................................ 3-2 Cleaning the Fan Filters................................................................................................. 3-2

Summary of the content on the page No. 8

Contents Table A-1. AC Input Specifications ........................................................................A-1 Table A-2. DC Output Specifications......................................................................A-2 Table A-3. Cooling Specifications ..........................................................................A-3 Table A-4. Safety Specifications .............................................................................A-3 Table A-5. Environmental Specifications......

Summary of the content on the page No. 9

About This Manual The PXI-1000 User Manual describes the features of the PXI-1000 mainframe and contains information about configuring the mainframe, installing the modules, and operating and using the PXI-1000. Organization of This Manual This manual is organized as follows: • Chapter 1, Getting Started, describes the key features of the PXI-1000, lists the contents of your kit, and lists optional equipment you can order from National Instruments. • Chapter 2, Installation and Configuration

Summary of the content on the page No. 10

About This Manual This icon to the left of bold italicized text denotes a warning, which advises you of precautions to take to avoid being electrically shocked. bold italic Bold italic text denotes a note, caution, or warning. italic Italic text denotes emphasis, a cross reference, or an introduction to a key concept. This font also denotes text from which you supply the appropriate word or value, as in Windows 3.x. monospace Text in this font denotes text or characters that are to be literal

Summary of the content on the page No. 11

1 Getting Started This chapter describes the key features of the PXI-1000, lists the contents of your kit, and lists optional equipment you can order from National Instruments. Unpacking Carefully inspect the shipping container and the mainframe for damage. Check for visible damage to the metal work. Check to make sure all handles, hardware, and switches are undamaged. Inspect the inner chassis for any possible damage, debris, or detached components. If damage appears to have been caused i

Summary of the content on the page No. 12

Chapter 1 Getting Started Table 1-1. Power Cables (Continued) Power Cable Reference Standards Universal Euro 240 V CEE (7), II, IV, VII IEC83 North America 240 V ANSI C73.20/NEMA 5-15-P/IEC83 United Kingdom 240 V BS 1363/IEC83 If you are missing any of the above items or if you have the incorrect power cord, contact National Instruments. Optional Equipment An optional rack-mount kit is available from National Instruments. You can use this kit to install the PXI-1000 mainframe into a standard

Summary of the content on the page No. 13

Chapter 1 Getting Started • Selectable fan speed for maximum cooling or quiet operation • Carrying handle for portability • Tilt feet for bench-top applications PXI-1000 Backplane Overview Interoperability with CompactPCI The PXI-1000 backplane is interoperable with PXI-compatible products and standard CompactPCI products. This is an important feature, as many PXI-compatible systems may not require components that do not implement PXI-specific features. For example, you may want to use a sta

Summary of the content on the page No. 14

Chapter 1 Getting Started 1 ON STANDBY 22 P2 1 25 2 P1 1 ZABCDEF 2 3 4 5 6 7 8 1 5 3 4 8 7 6 4 3 1 Remote On/Off (Standby) Switch 3 Optional Mounting Brackets 6 Star Trigger Slot 2 Backplane Connectors 4 Removable Feet 7 System Controller Slot (Located in Slots 1-8) 5 Peripheral Slots 8 Controller Expansion Slots Figure 1-1. Front View of the PXI-1000 Mainframe PXI-1000 User Manual 1-4 © National Instruments Corporation

Summary of the content on the page No. 15

Chapter 1 Getting Started 1 2 3 90-264 VAC 47-63 HZ 8A MAX CB1 10A DISCONNECT POWER CORD HI LO BEFORE REMOVING POWER MODULE FAN SPEED DB-9 7 6 5 4 1 Module Cooling Air Outlets 3 Main Power Switch 5 Chassis Ground Screw 7 Fan Speed Selector 2 Universal AC Input 4 Circuit Breaker 6 Remote Power Status and Inhibit Connector Figure 1-2. Rear View of the PXI-1000 Mainframe System Controller Slot The System Controller slot is located in Slot 1 of the chassis as defined by the PXI specification. It

Summary of the content on the page No. 16

Chapter 1 Getting Started Local Bus The PXI backplane’s local bus is a daisy-chained bus that connects each peripheral slot with its adjacent peripheral slots to the left and right, as shown in Figure 1-3. For example, a given peripheral slot’s right local bus connects to the adjacent slot’s left local bus and so on. Each local bus is 13 lines wide and can pass analog signals between cards or provide a high-speed side-band communication path that does not affect the PXI bandwidth. Local Bus

Summary of the content on the page No. 17

Chapter 1 Getting Started operations performed on other modules in the system. Modules can pass triggers to one another, allowing precisely timed responses to asynchronous external events the system is monitoring or controlling. System Reference Clock The PXI-1000 supplies the PXI 10 MHz system clock signal (PXI_CLK10) independently to each peripheral slot. An independent buffer (having a source impedance matched to the backplane and a skew of less than 1 ns between slots) drives the clock

Summary of the content on the page No. 18

2 Installation and Configuration This chapter describes how to prepare and operate your PXI-1000 mainframe. Before connecting the mainframe to a power source, read this chapter and the For Your Safety section located at the beginning of this manual. Site Considerations The PXI-1000 is designed to operate on a bench or in an instrument rack. Determine how you want to use your PXI-1000 and follow the appropriate installation instructions. Apertures in the rear and along both sides of the main

Summary of the content on the page No. 19

Chapter 2 Installation and Configuration 1 2 1 Module Cooling Air Outlets 2 Module Cooling Air Intake Figure 2-1. PXI-1000 Mainframe Airflow Side View Install your mainframe so that you can easily access the rear panel. This simplifies the replacement of the air filters or power supply/fan assembly, if necessary. Rack Mounting Rack-mount applications require the optional rack-mount kit available from National Instruments. Refer to the instructions supplied with the rack-mount kit to install

Summary of the content on the page No. 20

Chapter 2 Installation and Configuration Connecting Safety Ground Warning The PXI-1000 chassis is designed with a three-position NEMA 15-5 style plug that connects the ground line to the chassis ground. To minimize shock hazard, make sure your electrical power outlet has an appropriate earth safety ground that is connected whenever you power up the chassis. If your power outlet does not have an appropriate ground connection, you must connect the premise wire safety ground to the chassis grou


Alternative user manuals
# User manual Category Download
1 National Instruments 24-Bit Half/Full-Bridge Analog Input Module NI 9237 User manual Network Card 11
2 National Instruments 700 User manual Network Card 2
3 National Instruments 370620B-01 User manual Network Card 0
4 National Instruments 5411 User manual Network Card 0
5 National Instruments 6508 PCI-DIO-96 User manual Network Card 1
6 National Instruments 8-Channel Solid-State Relay (SSR) Digital Output NI 9485 User manual Network Card 6
7 National Instruments 8330 Series User manual Network Card 0
8 National Instruments AT E Series User manual Network Card 4
9 National Instruments BNC-2140 User manual Network Card 0
10 National Instruments 374318A-01 User manual Network Card 0
11 National Instruments Cabled PCI Express User manual Network Card 0
12 National Instruments AutoCode NI MATRIX User manual Network Card 1
13 National Instruments cFP-20xx User manual Network Card 0
14 National Instruments DAQCard-1200 User manual Network Card 6
15 National Instruments Data Acquisition Device NI USB-621x User manual Network Card 10
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1