ADTRAN 1200130L2 user manual

User manual for the device ADTRAN 1200130L2

Device: ADTRAN 1200130L2
Category: Network Router
Manufacturer: ADTRAN
Size: 0.51 MB
Added : 5/22/2013
Number of pages: 153
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ADTRAN 1200130L2. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ADTRAN 1200130L2.

For your convenience

If looking through the ADTRAN 1200130L2 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ADTRAN 1200130L2 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ADTRAN 1200130L2 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ADTRAN 1200130L2 User manual - Online PDF
Advertisement
« Page 1 of 153 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ADTRAN 1200130L2 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ADTRAN 1200130L2. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

FSU
Frame Relay Service Unit
USER MANUAL
1200130L1 FSU base unit
1200130L2 FSU w/built-in DSU
61200.130L1-1A
December 1996

Summary of the content on the page No. 2

This product includes software developed by the University of California, Berkeley, and its contributors. 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000 Phone: (205) 963-8000 © 1997 ADTRAN, Inc. All rights reserved. Printed in USA.

Summary of the content on the page No. 3

ABOUT THIS MANUAL This manual is arranged so you can quickly and easily find the information you need. The following is an overview of the contents of this manual: • Chapter 1, Introduction, familiarizes you with frame relay networks and FSU highlights and gives a brief explanation of options that may be purchased for use with the FSU. • Chapter 2, Installation, describes the FSU connectors (pin assignments are given in Appendix A) and provides an installation diagram. • Chapter 3, Operation, e

Summary of the content on the page No. 4

Notes provide additional useful information. Cautions signify information that could prevent service interruption. Warnings provide information that could prevent damage to the equipment or endangerment to human life.

Summary of the content on the page No. 5

FCC regulations require that the following information be provided in this manual: 1. This equipment complies with Part 68 of the FCC rules. On the bottom of the equipment housing is a label that shows the FCC registration number and Ringer Equivalence Number (REN) for this equipment. If requested, provide this information to the telephone company (REN is not required for some types of analog or digital facilities). 2. If this equipment causes harm to the telephone network, the telephone compan

Summary of the content on the page No. 6

FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual

Summary of the content on the page No. 7

CANADIAN EQUIPMENT LIMITATIONS Notice: The Canadian Industry and Science Canada label identifies certified equipment. This certification means that the equipment meets certain telecom- munications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfac- tion. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company.

Summary of the content on the page No. 8

Summary of the content on the page No. 9

Table of Contents Chapter 1. Introduction Understanding Frame Relay ................................................................................................. 1 Product Overview .................................................................................................................. 2 DDS Operation ........................................................................................................................ 3 56/64k DDS DSU Option ......................................

Summary of the content on the page No. 10

Table of Contents View Statistics (STATS) ................................................................................... 19 Diagnostics (DIAG) ......................................................................................... 19 Save Configuration (SAVE) ........................................................................... 20 Abort Changes (ABORT) ............................................................................... 20 Logout (VT 100 menu only) .......................

Summary of the content on the page No. 11

Table of Contents Example Route Table Entry .................................................................................. 80 Gateway IP Address (GW IP ADD) ............................................................................ 81 Gateway Port (GW PORT) ........................................................................................... 81 Gateway DLCI (GW DLCI) .......................................................................................... 81 Transmit ARP Requests (T

Summary of the content on the page No. 12

Table of Contents Ping ................................................................................................................................ 102 Address to Ping (PING ADDRESS) ................................................................... 102 Start Ping ............................................................................................................... 103 Loopback All Ports (LOOPBACK ENA) .................................................................. 104 Disable L

Summary of the content on the page No. 13

Table of Contents Figure 5-3 VT 100 Configuration Menu Tree............................................................... 37 Figure 6-1 VT 100 Port Configuration Menu............................................................... 39 Figure 6-2 Front Panel Protocol Menu Tree ................................................................. 40 Figure 6-3 Port Disabled Menu Tree ............................................................................. 41 Figure 6-4 Frame Relay Protocol Menu Tr

Summary of the content on the page No. 14

Table of Contents vi FSU User Manual 61200.130L1-1

Summary of the content on the page No. 15

Chapter 1. Introduction Chapter 1 Introduction UNDERSTANDING FRAME RELAY Frame relay is a wide area network (WAN) service designed to minimize physical connections. This is accomplished by using virtual connections within the frame relay cloud and accessing these virtual circuits with normally one physical connection at each location to the frame relay service. Virtual circuits are addressed using header information at the beginning of each frame. These frames are formatted by the user's CPE

Summary of the content on the page No. 16

Chapter 1. Introduction equipment. This DLCI is valid until the call is disconnected and may be assigned a different value each time a call is requested. PRODUCT OVERVIEW The FSU provides a low cost solution for the CPE equipment in a private or public frame relay network. The FSU connects to the frame relay network via 56/64k DDS (digital data service) or T1/FT1 access links. Connections to 56/64k DDS are made using an integral 56/64k DSU or an external DSU. T1/FT1 connections are made usi

Summary of the content on the page No. 17

Chapter 1. Introduction relay DTE MIB), RFC 1213 (MIB II), and ADTRAN Enterprise MIB. • DCE port supporting rates of up to 512 kbps. • Optional integrated 56/64 DDS DSU/CSU. • Telnet-provided remote terminal management control. • FLASH code space for easy software upgrades. DDS OPERATION DDS is a nationwide service that allows interconnection and transportation of data at speeds up to 64 kbps. The local ex- change carriers provide the local loop service to DDS customers and may provide data fo

Summary of the content on the page No. 18

Chapter 1. Introduction WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within five years from the date of shipment if it does not meet its published specifications or fails while in service. For detailed warranty, repair, and return information refer to the ADTRAN Equipment Warranty and Repair and Return Policy Procedure. Return Material Authorization (RMA) is required prior to returning equipment to ADTRAN. For service, RMA requests, or further information, contact o

Summary of the content on the page No. 19

Chapter 2. Installation Chapter 2 Installation UNPACK, INSPECT, POWER UP Receiving Inspection Carefully inspect the FSU for any damage that may have oc- curred in shipment. If damage is suspected, file a claim immedi- ately with the carrier and contact ADTRAN Customer Service (see the back cover of this manual). Keep the original shipping container to use for future shipment or verification of damage during shipment. ADTRAN Shipments Include The following items are included in ADTRAN shipmen

Summary of the content on the page No. 20

Chapter 2. Installation Power Up Each FSU unit is provided with a captive eight-foot power cord, terminated by a three-prong plug which connects to a grounded 115 VAC power receptacle. Power to the FSU must be provided from a grounded 115 VAC, 60 Hz receptacle. REAR PANEL The FSU is equipped with three DB-25 connectors labeled DTE 1, DTE 2, and DCE. Connections to the dedicated circuit, dial backup circuit (future enhancement), and VT 100 interface are provided through the 8-pin telco jacks l


Alternative user manuals
# User manual Category Download
1 ADTRAN 1200F User manual Network Router 6
2 ADTRAN 2300 User manual Network Router 0
3 ADTRAN ADSL2+ User manual Network Router 0
4 ADTRAN 1250 User manual Network Router 0
5 ADTRAN 1200130L1 User manual Network Router 0
6 ADTRAN All-rate Data Service/Channel Service Unit DSUIVESP User manual Network Router 0
7 ADTRAN 1200350L1 User manual Network Router 0
8 ADTRAN ACT 1900 User manual Network Router 0
9 ADTRAN DG834GV User manual Network Router 0
10 ADTRAN Express L768 User manual Network Router 0
11 ADTRAN Fractional T1 Tandem Channel Unit FT1-TDM User manual Network Router 0
12 ADTRAN Express 4120 User manual Network Router 0
13 ADTRAN Express XLT User manual Network Router 0
14 ADTRAN B8ZS User manual Network Router 0
15 ADTRAN Express L1.5 User manual Network Router 0
16 Sony BKS-R3202/R3210/R3220 User manual Network Router 77
17 Sony DVS-V3232B/V3232M User manual Network Router 3
18 Sony BVS-V3232 User manual Network Router 8
19 Sony DMX-WL1 User manual Network Router 6
20 Sony BVS-A3232 User manual Network Router 6